Variation in aluminum, iron, and particle concentrations in oxic groundwater samples collected by use of tangential-flow ultrafiltration with low-flow sampling

Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering.

[1]  Z. Szabó,et al.  Changes in sample collection and analytical techniques and effects on retrospective comparability of low-level concentrations of trace elements in ground water. , 2001, Water research.

[2]  T. K. Edwards,et al.  Field methods for measurement of fluvial sediment , 1998 .

[3]  L. Faires METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY- DETERMINATION OF METALS IN WATER BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY , 1993 .

[4]  Nancy E. Kinner,et al.  Role of physical heterogeneity in the interpretation of small‐scale laboratory and field observations of bacteria, microbial‐sized microsphere, and bromide transport through aquifer sediments , 1993 .

[5]  M. Shafer,et al.  A Critical Evaluation of Tangential-Flow Ultrafiltration for Trace Metal Studies in Freshwater Systems. 2. Total Mercury and Methylmercury , 2000 .

[6]  John R. Garbarino,et al.  Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Elements in Whole-Water Digests Using Inductively Coupled Plasma-Optical Emission Spectrometry and Inductively Coupled Plasma-Mass Spectrometry , 1998 .

[7]  G. G. Leppard,et al.  Characterization of aquatic colloids and macromolecules. 2. Key role of physical structures on analytical results. , 1995, Environmental science & technology.

[8]  V. Kennedy,et al.  Filter pore‐size effects on the analysis of Al, Fe, Mn, and Ti in water , 1974 .

[9]  Z. Szabó,et al.  Use of an ultra-clean sampling technique with inductively coupled plasma-mass spectrometry to determine trace-element concentrations in water from the Kirkwood-Cohansey Aquifer system, coastal plain, New Jersey , 1996 .

[10]  V. J. Janzer,et al.  Methods for determination of radioactive substances in water and fluvial sediments , 1976 .

[11]  M. Shafer,et al.  A Critical Evaluation of Tangential-Flow Ultrafiltration for Trace Metal Studies in Freshwater Systems. 1. Organic Carbon , 2000 .

[12]  Peter M. Kearl,et al.  Suggested Modifications to Ground Water Sampling Procedures Based on Observations from the Colloidal Borescope , 1992 .

[13]  D. Ronen,et al.  Application of a multi-layer sampler based on the dialysis cell technique for the study of trace metals in groundwater , 1989 .

[14]  P. Gschwend,et al.  Colloid mobilization in two Atlantic coastal plain aquifers: Field studies , 1990 .

[15]  C. Harris,et al.  METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY- USE OF A MODIFIED ULTRASONIC NEBULIZER FOR THE ANALYSIS OF LOW IONIC-STRENGTH WATER BY INDUCTIVELY COUPLED OPTICAL EMISSION SPECTROMETRY , 1997 .

[16]  Z. Szabó,et al.  Change in Field Turbidity and Trace Element Concentrations During Well Purging , 2000 .

[17]  S. Eisenreich,et al.  Characterization of soluble and colloidal phase metal complexes in river water by ultrafiltration. A mass-balance approach. , 1981, Environmental science & technology.

[18]  William R. Penrose,et al.  Mobility of plutonium and americium through a shallow aquifer in a semiarid region , 1990 .

[19]  F. D. Wilde,et al.  Ground-Water Data-Collection Protocols and Procedures for the National Water-Quality Assessment Program: Collection and Documentation of Water-Quality Samples and Related Data , 1995 .

[20]  Arthur J. Horowitz,et al.  Problems Associated with Using Filtration To Define Dissolved Trace Element Concentrations in Natural Water Samples , 1996 .

[21]  P. Gschwend,et al.  Sampling Colloids and Colloid‐Associated Contaminants in Ground Water , 1993 .

[22]  Arthur J. Horowitz,et al.  U.S. Geological Survey protocol for the collection and processing of surface-water samples for the subsequent determination of inorganic constituents in filtered water , 1994 .