Electrospray from hot embossed polymer microfluidic chips formed using laser machined and electroformed tools

The aim of this project was to develop high performance polymer microfluidic chips with reduced complexity for Electrospray Ionization Mass Spectrometry (ESI-MS) analysis. This paper presents the fabrication and testing of developed hot embossed open channel polymer microfluidic chips for ESI-MS. Hot embossing was done using a laser machined steel tool and an electroformed nickel tool on polystyrene (PS) and polycarbonate (PC) substrates. Stable electrosprays were generated at microchannel exits of replicated microchips without cover using a high voltage difference between a positive stainless steel electrode in the reservoir and a negative aluminum plate. Electrospray parameters such as; nozzle tip distance from counter electrode, ESI onset potential and duration were investigated. For open channel systems, the results show that the electric field for stable ES directly relates to the distance between the channel tip and counter electrode, onset potential applied and to the flow velocity of the test solution in the microchannel. Fluid is delivered as a result of electroosmosis due to an applied electric field and capillary action, thereby eliminating the need for external pressure devices. From experimental results, for an open-channel of 100μm width, 100μm depth, length 12.5mm attached to an open reservoir of diameter 2 mm, the optimum distance between the channel exit tip and counter electrode is 1.2 mm for initiation of electrospray at voltage of ~2000 volts. The laser machined steel tool was found to be more durable than the nickel tool for PS/PC microstructure fabrication.

[1]  D. Knapp,et al.  Monolithic column plastic microfluidic device for peptide analysis using electrospray from a channel opening on the edge of the device , 2007 .

[2]  Pio G. Iovenitti,et al.  Design and fabrication of polymer microfluidic chip for ESI-MS , 2007, SPIE Micro + Nano Materials, Devices, and Applications.

[3]  Leif Nyholm,et al.  Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip. , 2005, The Analyst.

[4]  Corso,et al.  A fully integrated monolithic microchip electrospray device for mass spectrometry , 2000, Analytical chemistry.

[5]  J. Henion,et al.  A polymeric microfluidic chip for CE/MS determination of small molecules. , 2001, Analytical chemistry.

[6]  Gwo-Bin Lee,et al.  Micro devices integrated with microchannels and electrospray nozzles using PDMS casting techniques , 2002 .

[7]  A Manz,et al.  Poly(dimethylsiloxane) electrospray devices fabricated with diamond-like carbon-poly(dimethylsiloxane) coated SU-8 masters. , 2003, Lab on a chip.

[8]  D. Knapp,et al.  Miniaturized multichannel electrospray ionization emitters on poly(dimethylsiloxane) microfluidic devices , 2001, Electrophoresis.

[10]  Jun Kameoka,et al.  An electrospray ionization source for integration with microfluidics. , 2002, Analytical chemistry.

[11]  Monica Veszelei,et al.  Poly(dimethylsiloxane) microchip: microchannel with integrated open electrospray tip. , 2004, Lab on a chip.

[12]  S. Jacobson,et al.  Novel microfabricated device for electrokinetically induced pressure flow and electrospray ionization mass spectrometry. , 2000, Journal of Chromatography A.

[13]  Polymer-based electrospray chips for mass spectrometry , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[14]  L. Nyholm,et al.  Sheathless electrospray from polymer microchips. , 2003, Analytical chemistry.

[15]  Y. Tai,et al.  A micromachined chip-based electrospray source for mass spectrometry. , 2000, Analytical chemistry.

[16]  P. Yager,et al.  Biotechnology at low Reynolds numbers. , 1996, Biophysical journal.

[17]  P. Kebarle A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry. , 2000, Journal of mass spectrometry : JMS.

[18]  Gwo-Bin Lee,et al.  A disposable poly(methylmethacrylate)‐based microfluidic module for protein identification by nanoelectrospray ionization‐tandem mass spectrometry , 2001, Electrophoresis.

[19]  Séverine Le Gac,et al.  A planar on-chip micro-nib interface for NanoESI–MS microfluidic applications , 2004 .

[20]  Yuehe Lin,et al.  Microfabricated isoelectric focusing device for direct electrospray ionization‐mass spectrometry , 2000, Electrophoresis.

[21]  S. Jacobson,et al.  Computer simulations of electrokinetic transport in microfabricated channel structures. , 1998, Analytical chemistry.

[22]  S. Shoji,et al.  Polymer microchip integrated with nano-electrospray tip for electrophoresis–mass spectrometry , 2008 .

[23]  Jun Kameoka,et al.  Chip-based P450 drug metabolism coupled to electrospray ionization-mass spectrometry detection. , 2003, Analytical chemistry.

[24]  Sequential electrospray analysis using sharp-tip channels fabricated on a plastic chip , 2001 .