Mini-beam collimator enables microcrystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a ;standard' beam from an undulator source, approximately 25-50 microm (FWHM) in the vertical and 50-100 microm in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 microm x 65 microm at the sample position. To meet growing user demand for beams to study samples of 10 microm or less, a ;mini-beam' apparatus was developed that conditions the focused beam to either 5 microm or 10 microm (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

[1]  H. Noller,et al.  Structural basis for translation termination on the 70S ribosome , 2008, Nature.

[2]  John E. Johnson,et al.  An optimal exposure strategy for cryoprotected virus crystals with lattice constants greater than 1000 Å , 2008, Journal of synchrotron radiation.

[3]  R. Stevens,et al.  High-Resolution Crystal Structure of an Engineered Human β2-Adrenergic G Protein–Coupled Receptor , 2007, Science.

[4]  M. Burghammer,et al.  Crystal structure of the human β2 adrenergic G-protein-coupled receptor , 2007, Nature.

[5]  Keiko Ikeda,et al.  The molecular organization of cypovirus polyhedra , 2007, Nature.

[6]  D. Bilderback,et al.  Single-bounce monocapillaries for focusing synchrotron radiation: modeling, measurements and theoretical limits. , 2006, Journal of synchrotron radiation.

[7]  Manfred Burghammer,et al.  Protein crystallography microdiffraction. , 2005, Current opinion in structural biology.

[8]  Robert A. Grothe,et al.  Structure of the cross-β spine of amyloid-like fibrils , 2005, Nature.

[9]  S. Harrison,et al.  How does radiation damage in protein crystals depend on X-ray dose? , 2003, Structure.

[10]  P. Emsley,et al.  The Crystal Structure of Tetanus Toxin Hc Fragment Complexed with a Synthetic GT1b Analogue Suggests Cross-linking between Ganglioside Receptors and the Toxin* , 2001, The Journal of Biological Chemistry.

[11]  R. MacKinnon,et al.  Potassium channel receptor site for the inactivation gate and quaternary amine inhibitors , 2001, Nature.

[12]  Oliver Weichenrieder,et al.  Structure and assembly of the Alu domain of the mammalian signal recognition particle , 2000, Nature.

[13]  E. Pebay-Peyroula,et al.  X-ray structure of bacteriorhodopsin at 2.5 angstroms from microcrystals grown in lipidic cubic phases. , 1997, Science.