Fellow eye comparison between the 1CU accommodative intraocular lens and the Acrysof MA30 monofocal intraocular lens.

PURPOSE To examine the near visual clinical performance of an accommodative intraocular lens (IOL) when compared with a standard monofocal IOL in a fellow eye comparison. DESIGN Prospective, randomized fellow eye comparison. METHODS Thirty patients (60 eyes) with bilateral cataracts but otherwise normal eyes were recruited from a single university hospital cataract waiting list. Patients were randomized to receive either the 1CU accommodative IOL in their first eye or the Acrysof MA30 monofocal IOL. The alternative lens was then implanted in the second eye 4 to 6 weeks later. At all follow-up visits, a full assessment was made of distance, near and reading visual performance, and accommodative amplitude. RESULTS Data are available for all patients at 6 months and 20 patients at 1 year. At 6 months, no difference was found in distance-corrected visual acuity between the two IOLs. Of the 1CU eyes, nine patients (30%) could read J6 or better at a reading speed of 80 words/min or better. In these nine patients, the mean difference in the amplitude of accommodation between the two eyes was 0.71 diopters. CONCLUSIONS No measurable variable distinguished eyes that developed functional reading vision from those that did not. The accommodative IOL appears to produce improved near vision in some eyes, but it does not work in all eyes, and in eyes where there is apparent accommodation, there is a discrepancy between subjective reading performance and the modest measured increase of accommodative amplitude.

[1]  Wolfgang Drexler,et al.  Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial. , 2004, Ophthalmology.

[2]  J. Marshall,et al.  A mathematical model of factors that influence the performance of accommodative intraocular lenses , 2004, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[3]  GORDON E. LEGGE,et al.  Psychophysics of Reading. VIII. The Minnesota Low- Vision Reading Test , 1989, Optometry and vision science : official publication of the American Academy of Optometry.

[4]  O. Nishi,et al.  Accommodation amplitude after lens refilling with injectable silicone by sealing the capsule with a plug in primates. , 1998, Archives of ophthalmology.

[5]  D J Coleman,et al.  Presbyopia, accommodation, and the mature catenary. , 2001, Ophthalmology.

[6]  B. Seitz,et al.  Short‐term blood‐aqueous barrier breakdown after implantation of the 1CU accommodative posterior chamber intraocular lens , 2002, Journal of cataract and refractive surgery.

[7]  Nhung X Nguyen,et al.  Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lenses. , 2004, Ophthalmology.

[8]  Coleman Dj,et al.  On the hydraulic suspension theory of accommodation. , 1986 .

[9]  M. Rosenfield,et al.  Repeatability of clinical measurements of the amplitude of accommodation. , 1996 .

[10]  Wolfgang Drexler,et al.  Intraocular lens movement caused by ciliary muscle contraction , 2003, Journal of cataract and refractive surgery.

[11]  Gordon E. Legge,et al.  Printed cards for measuring low-vision reading speed , 1995, Vision Research.

[12]  Adrian Glasser,et al.  Accommodation measurements in a prepresbyopic and presbyopic population , 2004, Journal of cataract and refractive surgery.

[13]  Adrian Glasser,et al.  Subjective and objective measurement of human accommodative amplitude , 2003, Journal of cataract and refractive surgery.

[14]  Stuart J. Cumming,et al.  Experience with an Accommodating IOL , 1996, Journal of cataract and refractive surgery.

[15]  Robert Montés-Micó,et al.  Distance and near contrast sensitivity function after multifocal intraocular lens implantation , 2003, Journal of cataract and refractive surgery.

[16]  J S Cumming,et al.  Clinical evaluation of the model AT-45 silicone accommodating intraocular lens: results of feasibility and the initial phase of a Food and Drug Administration clinical trial. , 2001, Ophthalmology.

[17]  J. Paugh,et al.  Characterization of visual phenomena with the Array multifocal intraocular lens , 2002, Journal of cataract and refractive surgery.

[18]  O Nishi,et al.  Lens refilling with injectable silicone in rabbit eyes , 1998, Journal of cataract and refractive surgery.

[19]  Alfred Vogel,et al.  Lens refilling and endocapsular polymerization of an injectable intraocular lens: In vitro and in vivo study of potential risks and benefits , 1994, Journal of cataract and refractive surgery.

[20]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review. , 2003, Ophthalmology.