A particle filter based autocontouring algorithm for lung tumor tracking using dynamic magnetic resonance imaging.

PURPOSE This study introduces a novel autocontouring algorithm based on particle filter for lung tumors. It is validated on dynamic magnetic resonance (MR) images and is developed in the context of MR-linac treatments. METHODS A sequential Monte Carlo method called particle filter is used as the main structure of the algorithm and is combined with Otsu's thresholding technique to contour lung tumors on dynamic MR images. Four non-small cell lung cancer (NSCLC) patients were imaged with a 1.5 T MR for 60 s at a rate of 4 images/s and were asked to breathe normally. Prior to treatment, some image processing is required by the proposed algorithm, which includes a manual contour of the tumor, the tumor's displacement, and its descriptive statistics. During treatment, the contours are automatically generated by thresholding around the center of mass of the particles. A comparison with the expert's contours is obtained by calculating the Dice similarity coefficient (DSC), the precision, the recall, the Hausdorff distance, and the difference in centroid positions (Δd). RESULTS This autocontouring algorithm is independent of pretreatment training and presents continuous adaptability as provided by the nature of particle filters. The number of particles is proportional to the area of the tumor and increases the computational time at a rate of 2 ms for every 500 particles, whereas the contouring step adds a constant 14 ms. The contours' comparison is obtained with a mean DSC of 0.89-0.91, mean precision of 0.88-0.91, mean recall of 0.89-0.95, and mean Δd of 0.6-2.0 mm. CONCLUSIONS This work presents a proof of concept of a new autocontouring algorithm for NSCLC patients on dynamic MR images. The contours were generated in good agreement with the expert's contours.

[1]  Guang-Zhong Yang,et al.  Non-rigid 2D-3D Registration with Catheter Tip EM Tracking for Patient Specific Bronchoscope Simulation , 2006, MICCAI.

[2]  Parag J. Parikh,et al.  Evaluation of linear accelerator gating with real-time electromagnetic tracking. , 2009, International journal of radiation oncology, biology, physics.

[3]  K. Wells,et al.  A Particle Filter Approach to Respiratory Motion Estimation in Nuclear Medicine Imaging , 2011, IEEE Transactions on Nuclear Science.

[4]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[5]  Haitao Wang,et al.  The Nerve Growth Factor Signaling and Its Potential as Therapeutic Target for Glaucoma , 2014, BioMed research international.

[6]  Daniel P. Huttenlocher,et al.  Comparing Images Using the Hausdorff Distance , 1993, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Stuart Crozier,et al.  The Australian magnetic resonance imaging-linac program. , 2014, Seminars in radiation oncology.

[8]  G Baroni,et al.  Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI , 2016, Physics in medicine and biology.

[9]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[10]  Jan J W Lagendijk,et al.  The magnetic resonance imaging-linac system. , 2014, Seminars in radiation oncology.

[11]  Namrata Vaswani,et al.  Tracking Deforming Objects Using Particle Filtering for Geometric Active Contours , 2007, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[12]  Xiutao Shi,et al.  Evaluation of template matching for tumor motion management with cine-MR images in lung cancer patients. , 2014, Medical physics.

[13]  Jeremy C. Durack,et al.  Complications Associated with the Percutaneous Insertion of Fiducial Markers in the Thorax , 2010, CardioVascular and Interventional Radiology.

[14]  Satyapal Rathee,et al.  First demonstration of intrafractional tumor-tracked irradiation using 2D phantom MR images on a prototype linac-MR. , 2013, Medical physics.

[15]  Andrew Jackson,et al.  High-tech will improve radiotherapy of NSCLC: a hypothesis waiting to be validated. , 2004, International journal of radiation oncology, biology, physics.

[16]  Steve Webb,et al.  Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: an experimental study. , 2008, Medical physics.

[17]  Steve B. Jiang,et al.  Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers , 2007, Physics in medicine and biology.

[18]  Y. Ung,et al.  Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC). , 2003, International journal of radiation oncology, biology, physics.

[19]  Paul Keall,et al.  Investigating the Feasibility of Rapid MRI for Image-Guided Motion Management in Lung Cancer Radiotherapy , 2014, BioMed research international.

[20]  Koichi Yamazaki,et al.  Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy , 2002, Cancer.

[21]  B. Fallone,et al.  The rotating biplanar linac-magnetic resonance imaging system. , 2014, Seminars in radiation oncology.

[22]  Erik Tryggestad,et al.  4D tumor centroid tracking using orthogonal 2D dynamic MRI: implications for radiotherapy planning. , 2013, Medical physics.

[23]  Oliver Bieri,et al.  Fundamentals of balanced steady state free precession MRI , 2013, Journal of magnetic resonance imaging : JMRI.

[24]  Neil J. Gordon,et al.  A tutorial on particle filters for online nonlinear/non-Gaussian Bayesian tracking , 2002, IEEE Trans. Signal Process..

[25]  Albert Koong,et al.  Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. , 2009, Journal of vascular and interventional radiology : JVIR.

[26]  Steve B. Jiang,et al.  MRI-guided tumor tracking in lung cancer radiotherapy , 2011, Physics in medicine and biology.

[27]  Ke Sheng,et al.  Accelerating dynamic magnetic resonance imaging (MRI) for lung tumor tracking based on low-rank decomposition in the spatial-temporal domain: a feasibility study based on simulation and preliminary prospective undersampled MRI. , 2014, International journal of radiation oncology, biology, physics.

[28]  Steffen Ringgaard,et al.  Three-dimensional liver motion tracking using real-time two-dimensional MRI. , 2014, Medical physics.

[29]  P. M. Jakob,et al.  MRI of the Lung – ready ... get set ... go ! , 2022 .

[30]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[31]  H. Shiomi,et al.  Evaluation of potential internal target volume of liver tumors using cine-MRI. , 2014, Medical physics.

[32]  S P M Crijns,et al.  Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion , 2012, Physics in medicine and biology.

[33]  Sasa Mutic,et al.  The ViewRay system: magnetic resonance-guided and controlled radiotherapy. , 2014, Seminars in radiation oncology.

[34]  Marcel van Herk,et al.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[35]  Satyapal Rathee,et al.  Neural-network based autocontouring algorithm for intrafractional lung-tumor tracking using Linac-MR. , 2015, Medical physics.

[36]  Rasmus Larsen,et al.  Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes , 2013, Physics in medicine and biology.

[37]  Sang Uk Lee,et al.  Robust segmentation of cerebral arterial segments by a sequential Monte Carlo method: Particle filtering , 2006, Comput. Methods Programs Biomed..

[38]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[39]  Y. Tsunashima,et al.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[40]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[41]  Joos V Lebesque,et al.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. , 2001, Radiotherapy and Oncology.

[42]  James J. Little,et al.  A Boosted Particle Filter: Multitarget Detection and Tracking , 2004, ECCV.

[43]  Satyapal Rathee,et al.  Evaluation of a lung tumor autocontouring algorithm for intrafractional tumor tracking using low-field MRI: a phantom study. , 2012, Medical physics.