Proficiency testing of wastewater sampling: What did we learn?

The proficiency testing of wastewater sampling is organized by the Laboratory for Environmental Sciences and Engineering at the National Institute of Chemistry, Slovenia (NIC). Preliminary tests started in 2010 at two candidate sites to choose for a trial the most convenient one. In 2012, we organized the first collaborative field trial on wastewater sampling and such trials continued in 2013 and 2014. Between 16 and 20 sampling teams were selected from those that (1) participate in the national wastewater monitoring program and (2) perform analytical activities in laboratories. The participants used a 6-h time proportional sampling approach. They used sampling equipment with different principles of sample collection which take a series of discrete samples at fixed time intervals. Subsequent analyses involved both field and laboratory measurements. The participants, with only one exception, exhibited required technical skills for measuring field parameters (temperature and pH value). All samples taken were also analyzed at NIC. The variability between reported values of participants in the trials, expressed as CV, was found to be 8.5 %, 11.1 % and 9.5 % for chemical oxygen demand. Of all parameters, the largest variability was found for total organic carbon concentration amounting to 23.7 % and 35.7 %. Particular attention was given to separate the measurement uncertainty contributions arising from sampling and chemical analyses.

[1]  A. Drolc,et al.  Uncertainty of chemical oxygen demand determination in wastewater samples , 2003 .

[2]  Michael H. Ramsey,et al.  Uncertainty from sampling, in the context of fitness for purpose , 2007 .

[3]  G. Bidoglio,et al.  Chemical-monitoring on-site exercises to harmonize analytical methods for priority substances in the European Union , 2012 .

[4]  M. Laine,et al.  Proficiency test of pH, conductivity and dissolved oxygen concentration field measurements in river water , 2014, Accreditation and Quality Assurance.

[5]  Nineta Majcen,et al.  Measurement traceability and its role in proficiency testing schemes – a case study for wastewater analysis in Slovenia , 2006 .

[6]  日本規格協会 試験所及び校正機関の能力に関する一般要求事項 = General requirements for the competence of testing and calibration laboratories = Prescriptions générales concernant la compétence des laboratoires d'étalonnages et d'essais , 2000 .

[7]  Michael Thompson,et al.  The International Harmonized Protocol for the proficiency testing of analytical chemistry laboratories (IUPAC Technical Report) , 2006 .

[8]  Vinicius Alves Pessanha,et al.  Proposta para acreditação da divisão de produção de painéis sorológicos de Bio-Manguinhos / Fiocruz na norma ISO / IEC 17043 - Conformity Assessment – General Requirements for Proficiency Testing , 2011 .

[9]  Filipe Medeiros Proficiency tests for laboratories: a systematic review , 2014 .

[10]  B. Geelhoed,et al.  Improved evaluation of measurement uncertainty from sampling by inclusion of between-sampler bias using sampling proficiency testing. , 2011, The Analyst.

[11]  H. Muntau,et al.  Estimation of measurement uncertainty by the budget approach for heavy metal content in soils under different land use , 2004 .

[12]  Michael Gluschke,et al.  Collaborative sampling trial in the context of quality assurance in the German marine monitoring programme for the North Sea and the Baltic Sea , 2008 .

[13]  Roger Wood,et al.  Empirical versus modelling approaches to the estimation of measurement uncertainty caused by primary sampling. , 2009, The Analyst.