Specimen dimensions influence the measurement of material properties in tendon fascicles

Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and cross-sectional area (CSA) appear to influence failure stress, strain and modulus in fascicles from two functionally different tendons. Fascicles were dissected from five rat tails and five bovine foot extensors, their diameters determined by a laser micrometer, and loaded to failure at a range of grip-to-grip lengths. Strain to failure significantly decreased with increasing in specimen length in both rat and bovine fascicles, while modulus increased. Specimen length did not influence failure stress in rat tail fascicles, although in bovine fascicles it was significantly lower in the longer 40 mm specimens compared to 5 and 10mm specimens. The variations in failure strain and modulus with sample length could be predominantly explained by end-effects. However, it was also evident that strain fields along the sample length were highly variable and notably larger towards the ends of the sample than the mid-section even at distances in excess of 5mm from the gripping points. Failure strain, stress and modulus correlated significantly with CSA at certain specimen lengths. Our findings have implications for the mechanical testing of tendon tissue: while it is not always possible to control for fascicle length and/or CSA, these parameters have to be taken into account when comparing samples of different dimensions.

[1]  M. Kjaer,et al.  Structural Achilles tendon properties in athletes subjected to different exercise modes and in Achilles tendon rupture patients. , 2005, Journal of applied physiology.

[2]  G. Brüggemann,et al.  The effect of running, strength, and vibration strength training on the mechanical, morphological, and biochemical properties of the Achilles tendon in rats. , 2007, Journal of applied physiology.

[3]  E. Zycband,et al.  Collagen fibrillogenesis in situ: Fibril segments become long fibrils as the developing tendon matures , 1997, Developmental dynamics : an official publication of the American Association of Anatomists.

[4]  Aaditya C Devkota,et al.  Mechanical response of tendon subsequent to ramp loading to varying strain limits. , 2003, Clinical biomechanics.

[5]  R. Sanjeevi,et al.  A viscoelastic model for collagen fibres. , 1982, Journal of biomechanics.

[6]  D. Parry,et al.  An estimate of the mean length of collagen fibrils in rat tail-tendon as a function of age. , 1989, Connective tissue research.

[7]  B H Ng,et al.  The Influence of Gripping Techniques on the Tensile Properties of Tendons , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  H. Stäubli,et al.  Effect of cyclic preconditioning on the tensile properties of human quadriceps tendons and patellar ligaments , 1998, Knee Surgery, Sports Traumatology, Arthroscopy.

[9]  D L Butler,et al.  Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments. , 1986, Journal of biomechanics.

[10]  Ray Vanderby,et al.  Collagen fibril morphology and organization: implications for force transmission in ligament and tendon. , 2006, Matrix biology : journal of the International Society for Matrix Biology.

[11]  J. Finlay,et al.  Microstructural organization of human and bovine cruciate ligaments. , 1978, Clinical orthopaedics and related research.

[12]  A. Amis,et al.  The anatomy of the patellar tendon , 2001, Knee Surgery, Sports Traumatology, Arthroscopy.

[13]  Robert G Cutlip,et al.  Comparison of mechanical properties of rat tibialis anterior tendon evaluated using two different approaches. , 2004, Bio-medical materials and engineering.

[14]  M. Kjaer,et al.  Region-specific mechanical properties of the human patella tendon. , 2005, Journal of applied physiology.

[15]  K. Min,et al.  The Effects of Anabolic Steroids on Rat Tendon , 1995, The American journal of sports medicine.

[16]  F. Goubel,et al.  Changes in stiffness induced by hindlimb suspension in rat Achilles tendon , 2000, European Journal of Applied Physiology.

[17]  M. Kjaer,et al.  Lateral force transmission between human tendon fascicles. , 2008, Matrix biology : journal of the International Society for Matrix Biology.

[18]  R. F. Ker,et al.  Mechanical properties of various mammalian tendons , 1986 .

[19]  E B Simonsen,et al.  The influence of strength training, swim training and ageing on the Achilles tendon and m. soleus of the rat. , 1995, Journal of sports sciences.

[20]  I. S. Young,et al.  Mechanical properties of tendons: changes with sterilization and preservation. , 1996, Journal of biomechanical engineering.

[21]  R. Haut,et al.  The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area. , 1999, Journal of biomechanics.

[22]  F. Goubel,et al.  Changes in stiffness induced by hindlimb suspension in rat soleus muscle , 2004, Pflügers Archiv.

[23]  R. Haut The influence of specimen length on the tensile failure properties of tendon collagen. , 1986, Journal of biomechanics.

[24]  Henry Eyring,et al.  The Mechanical Properties of Rat Tail Tendon , 1959, The Journal of general physiology.

[25]  S. Stover,et al.  Effect of maturation and aging on the histomorphometric and biochemical characteristics of equine superficial digital flexor tendon. , 1997, American journal of veterinary research.

[26]  F. Noyes,et al.  Effects of structure and strain measurement technique on the material properties of young human tendons and fascia. , 1984, Journal of biomechanics.

[27]  R. F. Ker Dynamic tensile properties of the plantaris tendon of sheep (Ovis aries). , 1981, The Journal of experimental biology.

[28]  K. Hayashi,et al.  Age-related changes in biomechanical properties of the Achilles tendon in rabbits , 2004, European Journal of Applied Physiology and Occupational Physiology.

[29]  R. F. Ker,et al.  The effect of temperature on the tensile stiffness of mammalian tail tendons , 1991 .