프런트 엔드 쿨링팩 일체형 냉각 모듈의 성능평가에 관한 연구
暂无分享,去创建一个
This study was performed the performance evaluation of integrated cooling module for front end cooling pack system. It was found the optimal geometry of integrated fin to reduce the heat conduction from the radiator to the condenser. The integrated fins have been applied to the radiator and the condenser. Numerical comparison of the performance is also made with that of the conventional separated fin. The heat capacity and pressure drop characteristics have been experimentally studied for the separated and integrated module. The results obtained indicate that the heat transfer performance of radiator is increased by 13%, outlet temperature of evaporator is decreased by 32% compared with those of the conventional separated module.
[1] 김재원,et al. 압축기 주변 유동의 활성화를 위한 유동 분배에 관한 연구 , 2005 .