The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: A comparison of serum, synovial fluid, albumin, EDTA, and water

Physical wear of orthopedic implants is inevitable. CoCr alloy samples, typically used in joint reconstruction, corrode rapidly after removal of the protective oxide layer. The behavior of CoCr pellets immersed in human serum, foetal bovine serum (FBS), synovial fluid, albumin in phosphate‐buffered saline (PBS), EDTA in PBS, and water were studied using X‐ray Photoelectron Spectroscopy (XPS) and Time‐of‐Flight Secondary Ion Mass Spectroscopy (ToF‐SIMS). The difference in the corrosive nature of human serum, water, albumin in PBS and synovial fluid after 5 days of immersion was highlighted by the oxide layer, which was respectively 15, 3.5, 1.5, and 1.5 nm thick. The thickness of an additional calcium phosphate deposit from human serum and synovial fluid was 40 and 2 nm, respectively. Co and Cr ions migrated from the bulk metal surface and were trapped in this deposit by the phosphate anion. This may account for the composition of wear debris from CoCr orthopedic implants, which is known to consist predominantly of hydroxy‐phosphate compounds. Known components of synovial fluid including proteoglycans, pyrophosphates, phospholipids, lubricin, and superficial zone protein (SZP), have been identified as possible causes for the lack of significant calcium phosphate deposition in this environment. Circulation of these compounds around the whole implant may inhibit calcium phosphate deposition. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:1587–1596, 2006

[1]  P. Heard,et al.  The effects of calcium phosphate deposition upon corrosion of CoCr alloys and the potential for implant failure. , 2005, Journal of biomedical materials research. Part A.

[2]  C. Case,et al.  Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants. , 2005, Journal of biomedical materials research. Part A.

[3]  T. Kokubo Design of bioactive bone substitutes based on biomineralization process , 2005 .

[4]  Y. Leng,et al.  Theoretical analysis of calcium phosphate precipitation in simulated body fluid. , 2005, Biomaterials.

[5]  M. Spector,et al.  Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty: correlation with flow properties. , 2004, Biomaterials.

[6]  C. Gohr In vitro models of calcium crystal formation , 2004, Current opinion in rheumatology.

[7]  A. Xenidis,et al.  Mechanism of aqueous uranium(VI) uptake by hydroxyapatite , 2004 .

[8]  G. Embery,et al.  Effect of serum albumin on glycosaminoglycan inhibition of hydroxyapatite formation. , 2004, Biomaterials.

[9]  Shing‐Jong Lin,et al.  Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications , 2004 .

[10]  J. Jacobs,et al.  Metal degradation products: a cause for concern in metal-metal bearings? , 2003, Clinical orthopaedics and related research.

[11]  Xing‐dong Zhang,et al.  Dissolution and mineralization behaviors of HA coatings. , 2003, Biomaterials.

[12]  Buddy D Ratner,et al.  Nacre surface transformation to hydroxyapatite in a phosphate buffer solution. , 2003, Biomaterials.

[13]  D. Zukor,et al.  Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. , 2003, Journal of biomedical materials research. Part A.

[14]  H. Pickering Important Early Developments and Current Understanding of the IR Mechanism of Localized Corrosion , 2003 .

[15]  P. Aspenberg,et al.  A Rat Model for Testing Pharmacologic Treatments of Pressure-Related Bone Loss , 2003, Clinical orthopaedics and related research.

[16]  P. Marques,et al.  Inorganic plasma with physiological CO2/HCO3- buffer. , 2003, Biomaterials.

[17]  I. Milošev,et al.  The influence of complexing agent and proteins on the corrosion of stainless steels and their metal components , 2003, Journal of materials science. Materials in medicine.

[18]  M. Maitz,et al.  Promoted calcium-phosphate precipitation from solution on titanium for improved biocompatibility by ion implantation , 2002 .

[19]  R. Cabrini,et al.  An experimental study of the dissemination of Titanium and Zirconium in the body , 2002, Journal of materials science. Materials in medicine.

[20]  J. Hirose,et al.  Animal models of pathologic calcification. , 2002, Current opinion in rheumatology.

[21]  B. Wroblewski,et al.  Surface-Active Phospholipid in Total Hip Arthroplasty , 2002, Clinical orthopaedics and related research.

[22]  G. Jay,et al.  Homology of lubricin and superficial zone protein (SZP): Products of megakaryocyte stimulating factor (MSF) gene expression by human synovial fibroblasts and articular chondrocytes localized to chromosome 1q25 , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  L. Ryan The ank gene story , 2000, Arthritis Research & Therapy.

[24]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[25]  B. Wroblewski,et al.  Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses , 2000, Journal of materials science. Materials in medicine.

[26]  D. Goodman,et al.  Solid-Liquid Adsorption of Calcium Phosphate on TiO2 , 1999 .

[27]  J. Fisher,et al.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements , 1999, Journal of materials science. Materials in medicine.

[28]  M. Wakamura,et al.  Surface composition of calcium hydroxyapatite modified with metal ions , 1998 .

[29]  Jack R. Worrall,et al.  Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. , 1998, Journal of biomedical materials research.

[30]  P. Aspenberg,et al.  Migration, particles, and fluid pressure. A discussion of causes of prosthetic loosening , 1998 .

[31]  R. Marti,et al.  Fluid Pressure Causes Bone Resorption in a Rabbit Model of Prosthetic Loosening , 1998, Clinical orthopaedics and related research.

[32]  Joshua J. Jacobs,et al.  Corrosion of metal orthopaedic implants. , 1998, The Journal of bone and joint surgery. American volume.

[33]  M. Wakamura,et al.  Influence of chromium(III) on the formation of calcium hydroxyapatite , 1997 .

[34]  P. Gallé,et al.  Role of alveolar macrophage lysosomes in metal detoxification , 1997, Microscopy research and technique (Print).

[35]  B. Hills Synovial surfactant and the hydrophobic articular surface. , 1996, The Journal of rheumatology.

[36]  T. Bauer,et al.  Characterization and Comparison of Wear Debris from Failed Total Hip Implants of Different Types* , 1996, The Journal of bone and joint surgery. American volume.

[37]  J. Galante,et al.  Local and distant products from modularity. , 1995, Clinical orthopaedics and related research.

[38]  M. Graham The application of surface techniques in understanding corrosion phenomena and mechanisms , 1995 .

[39]  Y. Okamoto,et al.  Studies on calcium phosphate precipitation: effects of metal ions used in dental materials. , 1994, Journal of biomedical materials research.

[40]  J. Galante,et al.  Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. , 1994, The Journal of bone and joint surgery. American volume.

[41]  C. Case,et al.  Widespread dissemination of metal debris from implants. , 1994, The Journal of bone and joint surgery. British volume.

[42]  S. Santavirta,et al.  Hyaluronate in total hip replacement. , 1993, The Journal of rheumatology.

[43]  W. Harris,et al.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. , 1992, The Journal of bone and joint surgery. American volume.

[44]  T. Hanawa,et al.  Calcium phosphate naturally formed on titanium in electrolyte solution. , 1991, Biomaterials.

[45]  J. Watts,et al.  An Introduction to Surface Analysis by XPS and AES , 1990 .

[46]  Ingemar Lundström,et al.  Auger electron spectroscopic studies of the interface between human tissue and implants of titanium and stainless steel , 1986 .

[47]  I. Lundström,et al.  Auger electron spectroscopic studies of stainless-steel implants. , 1985, Journal of biomedical materials research.

[48]  M. Grynpas,et al.  Inhibition of hydroxyapatite formation in collagen gels by chondroitin sulphate. , 1985, The Biochemical journal.

[49]  K. Pritzker,et al.  Pyrophosphate, phosphate ion interaction: effects on calcium pyrophosphate and calcium hydroxyapatite crystal formation in aqueous solutions. , 1983, The Journal of rheumatology.

[50]  C. Berry,et al.  Bone and Joint Disease , 1982, Current Topics in Pathology.

[51]  N. D. Tomashov,et al.  The passivation of alloys on titanium bases , 1974 .

[52]  G. C. Allen,et al.  X-Ray photoelectron spectroscopy of chromium–oxygen systems , 1973 .