CLIMATE BASED SIMULATION OF DIFFERENT SHADING DEVICE SYSTEMS FOR COMFORT AND ENERGY DEMAND

This study investigates in detail conventional and advanced shading devices. Thermal and visual aspects are considered as well as advanced control strategies. The systems are compared regarding energy balances, daylight provision and visual comfort aspects (glare, view contact). Outside mounted systems offer in all investigated cases best solar protection. A combination of external shading and internal glare protection can reduce the overall energy demand by more than 25% compared to a solar control glazing and/or only internal mounted shadings. High reflective internal mounted shadings cannot reach the performance of external shadings. They can improve the cooling demand compared to a standard internal mounted blind system, but only if high quality sufaces are used.

[1]  Jens Christoffersen,et al.  Towards a new daylight glare rating , 2005 .

[2]  Athanasios Tzempelikos,et al.  Indoor thermal environmental conditions near glazed facades with shading devices - Part II: Thermal comfort simulation and impact of glazing and shading properties , 2010 .

[3]  J. Wienold DYNAMIC DAYLIGHT GLARE EVALUATION , 2009 .

[4]  Roland Schregle,et al.  Daylight simulation with photon maps , 2005 .

[5]  Christoph F. Reinhart,et al.  Monitoring manual control of electric lighting and blinds , 2003 .

[6]  Wong Nyuk Hien,et al.  Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore , 2005 .

[7]  Georgios A. Florides,et al.  Modeling of the modern houses of Cyprus and energy consumption analysis , 2000 .

[8]  Tilmann E. Kuhn,et al.  Evaluation of overheating protection with sun-shading systems , 2001 .

[9]  Sebastian Herkel,et al.  Solar control: A general method for modelling of solar gains through complex facades in building simulation programs , 2011 .

[10]  Martin Vraa Nielsen,et al.  Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight , 2011 .

[11]  Hans Simmler,et al.  Experimental and numerical determination of the total solar energy transmittance of glazing with venetian blind shading , 2008 .

[12]  François Garde,et al.  Assessment of the thermal and visual efficiency of solar shades , 2011 .

[13]  Danny H.W. Li,et al.  An analysis of daylighting performance for office buildings in Hong Kong , 2008 .

[14]  Jens Christoffersen Evalglare. A new RADIANCE-based tool to evaluate glare in office spaces , 2004 .

[15]  A. Athienitis,et al.  The impact of shading design and control on building cooling and lighting demand , 2007 .

[16]  Christoph F. Reinhart,et al.  Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds , 2001 .

[17]  Tilmann E. Kuhn Solar control: Comparsion of two new systems with the state of the art on the basis of a new general evaluation method for facades with venetian blinds or other solar control systems , 2006 .