Shape memory alloy (SMA)-based head and neck immobilizer for radiotherapy

Abstract Head-and-neck cancer is often treated with intensive irradiation focused on the tumor, while delivering the minimum amount of irradiation to normal cells. Since a course of radiotherapy can take 5–6 weeks or more, the repeatability of the patient posture and the fastening method during treatment are important determinants of the success of radiotherapy. Many devices have been developed to minimize positional discrepancies, but all of the commercial devices used in clinical practice are operated manually and require customized fixtures for each patient. This is inefficient and the performance of the fixture device depends on the operator׳s skill. Therefore, this study developed an automated head-and-neck immobilizer that can be used during radiotherapy and evaluated the positioning reproducibility in a phantom experiment. To eliminate interference caused by the magnetic field from computed tomography hardware, Ni−Ti shape-memory alloy wires were used as the actuating elements of the fixtures. The resulting positional discrepancy was less than 5 mm for all positions, which is acceptable for radiotherapy.

[1]  R Mohan,et al.  The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.

[2]  L B Marks,et al.  A customized head and neck support system. , 1995, International journal of radiation oncology, biology, physics.

[3]  Sung-Hoon Ahn,et al.  Cross-shaped twisting structure using SMA-based smart soft composite , 2014 .

[4]  Sung-Hoon Ahn,et al.  Review of manufacturing processes for soft biomimetic robots , 2009 .

[5]  V. Khoo,et al.  The dosimetric consequences of anatomic changes in head and neck radiotherapy patients , 2010, Journal of medical imaging and radiation oncology.

[6]  Sung-Hoon Ahn,et al.  A turtle-like swimming robot using a smart soft composite (SSC) structure , 2012 .

[7]  C. Enke,et al.  Immobilization devices for intensity-modulated radiation therapy (IMRT). , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[8]  R. Laing,et al.  Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame. , 1993, The British journal of radiology.

[9]  R K Ten Haken,et al.  Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.