Systematic distortions in magnetic position digitizers.

Medical devices equipped with position sensors enable applications like image guided surgical interventions, reconstruction of three-dimensional 3D ultrasound (US) images, and virtual or augmented reality systems. The acquisition of three-dimensional position data in real time is one of the key technologies in this field. The systematic distortions induced by various metals, surgical tools, and US scan probes in different commercial electromagnetic tracking systems were assessed in the presented work. A precise nonmetallic six degree-of-freedom measurement rack was built that allowed a quantitative comparison of different electromagnetic trackers. Also, their performance in the presence of large metallic structures was quantified in a phantom study on an acrylic skull model in an operating room (OR). The trackers used were alternating current (ac) and direct current (dc) based systems. The ac trackers were, on average, distorted by 0.7 mm and 0.5 degree by metallic objects positioned at a distance greater than 120 mm between the geometrical center of the sample and the sensor. In the OR environment, the ac system exhibits mean errors of 3.2 +/- 2.4 mm and 2.9 degrees +/- 1.9 degrees. The dc trackers are more sensitive to distortions caused by ferromagnetic materials (averaged value: 1.6 mm and 0.5 degree beyond a distance of 120 mm). The dc tracker shows no distortions from other conductive materials but was less accurate in the OR environment (typical error: 6.4 +/- 2.5 mm and 4.9 degrees +/- 2.0 degrees). At distances smaller than approximately 100 mm between sample and sensor error increases quickly. It is also apparent from our measurements that the influence of US scan probes is governed by their shielding material. The results show that surgical instruments not containing conductive material are to be preferred when using an ac tracker. Nonferromagnetic instruments should be used with dc trackers. Static distortions caused by the OR environment have to be compensated by precise calibration methods.

[1]  Richard M. Satava,et al.  Virtual Environments for Medical Training and Education , 1997, Presence: Teleoperators & Virtual Environments.

[2]  Russell H. Taylor,et al.  An automated system for precise percutaneous access of the renal collecting system , 1997, CVRMed.

[3]  Philippe Cinquin,et al.  Using a 3D Position Sensor for Registration of SPECT and US Images of the Kidney , 1995, CVRMed.

[4]  R. Llinás,et al.  The interactive use of magnetoencephalography in stereotactic image-guided neurosurgery. , 1996, Neurosurgery.

[5]  P. Kelly,et al.  A stereotactic magnetic field digitizer. , 1994, Stereotactic and functional neurosurgery.

[6]  F. Jolesz,et al.  1996 RSNA Eugene P. Pendergrass New Horizons Lecture. Image-guided procedures and the operating room of the future. , 1997, Radiology.

[7]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.

[8]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[9]  Mark A. Livingston,et al.  Magnetic Tracker Calibration for Improved Augmented Reality Registration , 1997, Presence: Teleoperators & Virtual Environments.

[10]  A Wagner,et al.  Image-guided surgery. , 1996, International journal of oral and maxillofacial surgery.

[11]  Margaret E. Daube-Witherspoon,et al.  A head motion measurement system suitable for emission computed tomography , 1997, IEEE Transactions on Medical Imaging.

[12]  Thomas A. DeFanti,et al.  Ultrasonic calibration of a magnetic tracker in a virtual reality space , 1995, Proceedings Virtual Reality Annual International Symposium '95.

[13]  M. Fried,et al.  Image‐Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System , 1997, The Laryngoscope.

[14]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[15]  D. Leotta,et al.  Intragastric distribution and gastric emptying assessed by three-dimensional ultrasonography. , 1997, Gastroenterology.

[16]  N Shinozuka,et al.  Transvaginal sonographic orientation detection system using ceramic gyroscopes. , 1996, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[17]  Terry M. Peters,et al.  Three-dimensional multimodal image-guidance for neurosurgery , 1996, IEEE Trans. Medical Imaging.

[18]  H F Reinhardt,et al.  Micro-stereometry: a frameless computerized navigating system for open microsurgery. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[19]  Steve T. Bryson Measurement and calibration of static distortion of position data from 3D trackers , 1992, Electronic Imaging.

[20]  M. Murphy An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery. , 1997, Medical physics.

[21]  Frank Biocca,et al.  A Survey of Position Trackers , 1992, Presence: Teleoperators & Virtual Environments.

[22]  C. J. Thompson,et al.  Motion correction of PET images using multiple acquisition frames , 1997, IEEE Transactions on Medical Imaging.

[23]  A Wagner,et al.  Computed intraoperative navigation guidance--a preliminary report on a new technique. , 1997, The British journal of oral & maxillofacial surgery.

[24]  Derek L. G. Hill,et al.  Craniotomy simulation and guidance using a stereo video based tracking system (VISLAN) , 1994, Other Conferences.

[25]  Jack B. Kuipers SPASYN-an electromagnetic relative position and orientation tracking system , 1980, IEEE Transactions on Instrumentation and Measurement.

[26]  P. Cinquin,et al.  Computer assisted medical interventions , 1995 .

[27]  Y Watanabe,et al.  A system for nonradiographic source localization and real-time planning of intraoperative high dose rate brachytherapy. , 1997, Medical physics.