Study of an axial flow cyclone to remove nanoparticles in vacuum.

An axial flow cyclone for removing nanoparticles was tested for collection efficiency. Data were validated numerically in vacuum conditions of several Torrs, with flow rates of 0.35-0.57 slpm. The experimental cutoff aerodynamic diameter of the cyclone ranged from 21.7 to 49.8 nm. A 3-D numerical simulation was conducted first to calculate detailed flow and pressure fields, then a Brownian Dynamics simulation was done to determine the collection efficiency of nanoparticles. Both centrifugal force and Brownian diffusion were taken into account. The simulated results for both pressure drop and cutoff aerodynamic diameter are in good agreement with the experimental data. In comparison, previous theories using simplified tangential flow field assumption are not able to predict collection efficiencies accurately. The numerical model developed in this study can facilitate cyclone design to classify valuable nanopowders below a certain diameter, or to remove toxic nanoparticles from the vacuum exhaust of process chambers commonly used in high-tech industries.

[1]  D. Leith,et al.  Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions , 1985 .

[2]  K. W. Lee,et al.  Effects of cone dimension on cyclone performance , 2001 .

[3]  Andrew D. Maynard,et al.  A simple model of axial flow cyclone performance under laminar flow conditions , 2000 .

[4]  Pratim Biswas,et al.  Theoretical and experimental study of an axial flow cyclone for fine particle removal in vacuum conditions , 2004 .

[5]  J. Derksen,et al.  An experimental and numerical study of turbulent swirling flow in gas cyclones , 1999 .

[6]  N. P. Vaughan,et al.  Construction and testing of an axial flow cyclone preseparator , 1988 .

[7]  SIMULATION OF TURBULENT FLOW IN A CYCLONIC SEPARATOR , 2003 .

[8]  S. Chandrasekhar Stochastic problems in Physics and Astronomy , 1943 .

[9]  K. W. Lee,et al.  EXPERIMENTAL STUDY ON SMALL CYCLONES OPERATING AT HIGH FLOWRATES , 1999 .

[10]  Jim Swithenbank,et al.  EXPERIMENTAL AND THEORETICAL STUDIES OF CYCLONE SEPARATOR AERODYNAMICS , 1983 .

[11]  Ahmadun Fakhru’l-Razi,et al.  Prediction of the effects of cone tip diameter on the cyclone performance , 2005 .

[12]  David Leith,et al.  The Logistic Function and Cyclone Fractional Efficiency , 1990 .

[13]  Chuen-Jinn Tsai,et al.  Axial flow cyclone for segregation and collection of ultrafine particles: theoretical and experimental study. , 2005, Environmental science & technology.

[14]  C. E. Lapple Gravity and Centrifugal Separation , 1950 .

[15]  Chuen-Jinn Tsai,et al.  Field Study of the Accuracy of Two Respirable Sampling Cyclones , 1999 .

[16]  D. L. Iozia,et al.  Effect of Cyclone Dimensions on Gas Flow Pattern and Collection Efficiency , 1989 .

[17]  Wang Yingmin,et al.  A new collection theory of cyclone separators , 1989 .

[18]  Chuen-Jinn Tsai,et al.  On the Theory of Particle Cutoff Diameter and Collection Efficiency of Cyclones , 2001 .

[19]  P. W. Dietz,et al.  Collection efficiency of cyclone separators , 1981 .

[20]  Frank Thiele,et al.  Comparison of numerical methods applied to the flow over wall-mounted cubes , 2002 .