Condensation at the exterior surface of windows

Abstract New energy efficient windows have a higher risk for outdoor air vapour condensing to their exterior surface, when compared to older windows with lower thermal resistance. This external condensation can reduce visibility through the window, decrease owner satisfaction and affect the behaviour of window buyers and sellers. The purpose of this study was to analyse the impact of window U-value and other factors on the occurrence of external condensation. A combined heat and moisture transfer model was created and used for the calculations. According to the results, the duration and amount of external condensation are projected to increase in the future due to lower window U-values and climate change. Exterior surface emissivity, external shadings and building location had a big impact on the amount of yearly condensation hours, while window orientation and solar absorption coefficient had a smaller impact. There was also an interesting power-law-type correlation between yearly condensation hours and the median effective thickness of the condensation layer. The results help window manufacturers and building designers make more accurate decisions in their future work.

[1]  Targo Kalamees,et al.  Energy demand for the heating and cooling of residential houses in Finland in a changing climate , 2015 .

[2]  Paul Berdahl,et al.  Characteristics of infrared sky radiation in the United States , 1984 .

[3]  Leif Gustavsson,et al.  Implementation of energy-efficient windows in Swedish single-family houses , 2012 .

[4]  Neville Samuel Billington Building Physics: Heat , 1967 .

[5]  J. Jokisalo,et al.  Development of weighting factors for climate variables for selecting the energy reference year according to the EN ISO 15927-4 standard , 2012 .

[6]  Anna Werner External Water Condensation and Angular Solar Absorptance : Theoretical Analysis and Practical Experience of Modern Windows , 2007 .

[7]  Petter Wallentén,et al.  The Treatment of Long-Wave Radiation and Precipitation in Climate Files for Building Physics Simulations , 1995 .

[8]  Elina Manelius,et al.  Ilmastonmuutoksen ja lämmöneristyksen lisäyksen vaikutukset vaipparakenteiden kosteusteknisessä toiminnassa ja rakennusten energiankulutuksessa , 2013 .

[9]  Carlos F.M. Coimbra,et al.  On the determination of atmospheric longwave irradiance under all-sky conditions , 2017 .

[10]  Helena Bülow-Hübe,et al.  Energy-Efficient Window Systems - Effects on Energy Use and Daylight in Buildings , 2001 .

[11]  Piotr Klemm,et al.  Non-contact methods of measuring moisture concentration in external layers of building partitions. I—The influence of geometrical microstructure on the kinetics of moisture condensation on glass surfaces , 2002 .

[12]  A. Roos,et al.  Condensation tests on glass samples for energy efficient windows , 2007 .

[13]  Hugo Hens Applied Building Physics: Boundary Conditions, Building Performance and Material Properties , 2010 .

[14]  Bertil Jonsson Calculating the occurrence of external condensation on high-performance windows , 1999 .

[15]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[16]  Gerald N. Flerchinger,et al.  Comparison of algorithms for incoming atmospheric long‐wave radiation , 2009 .

[17]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[18]  Bertil Jonsson Utvändig kondens på fönster. Mätningar i Borås 1994. , 1995 .

[19]  A. C. Dilley,et al.  Estimating downward clear sky long‐wave irradiance at the surface from screen temperature and precipitable water , 1998 .

[20]  W. Chow,et al.  Solar radiation model , 2001 .

[21]  T. M. Crawford,et al.  An Improved Parameterization for Estimating Effective Atmospheric Emissivity for Use in Calculating Daytime Downwelling Longwave Radiation , 1999 .

[22]  Stephan Ulrich,et al.  Condensation on the outdoor surface of window glazing — Calculation methods, key parameters and prevention with low-emissivity coatings , 2013 .

[23]  Arne Roos,et al.  Simulations of coatings to avoid external condensation on low U-value windows , 2008 .

[24]  Mikko Valkama,et al.  Applicability of Frequency Selective Surfaces to Enhance Mobile Network Coverage in Future Energy-Efficient Built Environments , 2015 .