A 2-D Ultrasound Transducer With Front-End ASIC and Low Cable Count for 3-D Forward-Looking Intravascular Imaging: Performance and Characterization

Intravascular ultrasound (IVUS) is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking IVUS (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2-D array transducers, which present major challenges in reducing cable count and device integration. In this work, we present an 80-element lead zirconium titanate matrix ultrasound transducer for FL-IVUS imaging with a front-end application-specific integrated circuit (ASIC) requiring only four cables. After investigating optimal transducer designs, we fabricated the matrix transducer consisting of 16 transmit (TX) and 64 receive (RX) elements arranged on top of an ASIC having an outer diameter of 1.5 mm and a central hole of 0.5 mm for a guidewire. We modeled the transducer using finite-element analysis and compared the simulation results to the values obtained through acoustic measurements. The TX elements showed uniform behavior with a center frequency of 14 MHz, a −3-dB bandwidth of 44%, and a transmit sensitivity of 0.4 kPa/V at 6 mm. The RX elements showed center frequency and bandwidth similar to the TX elements, with an estimated receive sensitivity of $3.7~\mu \text{V}$ /Pa. We successfully acquired a 3-D FL image of three spherical reflectors in water using delay-and-sum beamforming and the coherence factor method. Full synthetic-aperture acquisition can be achieved with frame rates on the order of 100 Hz. The acoustic characterization and the initial imaging results show the potential of the proposed transducer to achieve 3-D FL-IVUS imaging.

[1]  R. Ross Atherosclerosis is an inflammatory disease , 1999 .

[2]  Graham A Wright,et al.  Innovations in imaging for chronic total occlusions: a glimpse into the future of angiography's blind-spot. , 2008, European heart journal.

[3]  Amin Nikoozadeh,et al.  First In Vivo Use of a Capacitive Micromachined Ultrasound Transducer Array–Based Imaging and Ablation Catheter , 2012, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  I. Nikolov,et al.  Fast simulation of ultrasound images , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[5]  F. L. Degertekin,et al.  Fabrication and characterization of cMUTs for forward looking intravascular ultrasound imaging , 2003, IEEE Symposium on Ultrasonics, 2003.

[6]  Omer Oralkan,et al.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy , 2011, Journal of micromechanics and microengineering : structures, devices, and systems.

[7]  Patrick W Serruys,et al.  Imaging of coronary atherosclerosis: intravascular ultrasound. , 2010, European heart journal.

[8]  David M. Mills,et al.  4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Toby Xu,et al.  3-D real-time volumetric imaging using 20 MHz 1.5-mm diameter single-chip CMUT-on-CMOS array , 2012, 2012 IEEE International Ultrasonics Symposium.

[10]  Antonio Colombo,et al.  Percutaneous recanalization of chronically occluded coronary arteries: a consensus document: part I. , 2005, Circulation.

[11]  R. Virmani,et al.  Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. , 2000, Arteriosclerosis, thrombosis, and vascular biology.

[12]  Edward D. Light,et al.  Two Dimensional Arrays for Real Time 3D Intravascular Ultrasound , 2004 .

[13]  Andre Bezanson,et al.  Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  E.D. Light,et al.  Real-time 3-D ultrasound guidance of interventional devices , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  P. Serruys,et al.  IVUS-based imaging modalities for tissue characterization: similarities and differences , 2011, The International Journal of Cardiovascular Imaging.

[16]  O. Oralkan,et al.  CMUT ring arrays for forward-looking intravascular imaging , 2004, IEEE Ultrasonics Symposium, 2004.

[17]  Chao Chen,et al.  A front-end ASIC with high-voltage transmit switching and receive digitization for forward-looking intravascular ultrasound , 2017, 2017 IEEE Custom Integrated Circuits Conference (CICC).

[18]  K. Shung,et al.  20 MHz forward-imaging single-element beam steering with an internal rotating variable-angle reflecting surface: Wire phantom and ex vivo pilot study. , 2013, Ultrasonics.

[19]  M. O'Donnell,et al.  Synthetic phased arrays for intraluminal imaging of coronary arteries , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Butrus T. Khuri-Yakub,et al.  Capacitive Micromachined Ultrasonic Transducers: Theory and Technology , 2003 .

[21]  Qifa Zhou,et al.  PMN-PT single-crystal high-frequency kerfless phased array , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[22]  Nico de Jong,et al.  A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[23]  M. Karaman,et al.  Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Najib N. Abboud,et al.  Finite element modeling for ultrasonic transducers , 1998, Medical Imaging.

[25]  Toby Xu,et al.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  M. O'Donnell,et al.  Coherence factor of speckle from a multi-row probe , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[27]  Chris L de Korte,et al.  Vascular ultrasound for atherosclerosis imaging , 2011, Interface Focus.

[28]  D.N. Stephens,et al.  Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  Michael J. Vonesh,et al.  Arterial Imaging With a New Forward‐Viewing Intravascular Ultrasound Catheter, I: Initial Studies , 1994, Circulation.

[31]  Toby Xu,et al.  Real-time imaging system using a 12-MHz forward-looking catheter with single chip CMUT-on-CMOS array , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[32]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[33]  Matthew O'Donnell,et al.  Experimental Studies With a 9F Forward‐Looking Intracardiac Imaging and Ablation Catheter , 2009, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[34]  D.N. Stephens,et al.  CMOS chip for invasive ultrasound imaging , 1994 .

[35]  Michael J. Vonesh,et al.  Arterial Imaging With a New Forward‐Viewing Intravascular Ultrasound Catheter, II: Three‐Dimensional Reconstruction and Display of Data , 1994, Circulation.

[36]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[37]  D.N. Stephens,et al.  Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[38]  M. O’Donnell,et al.  Initial results from a forward-viewing ring-annular ultrasound array for intravascular imaging , 2003, IEEE Symposium on Ultrasonics, 2003.

[39]  Johan G. Bosch,et al.  Sparse Ultrasound Image Reconstruction From a Shape-Sensing Single-Element Forward-Looking Catheter , 2018, IEEE Transactions on Biomedical Engineering.

[40]  Johan G Bosch,et al.  Preclinical Testing of Frequency-Tunable Capacitive Micromachined Ultrasonic Transducer Probe Prototypes. , 2017, Ultrasound in medicine & biology.

[41]  Gary S. Mintz,et al.  Percutaneous Recanalization of Chronically Occluded Coronary Arteries: A Consensus Document Part II , 2005, Circulation.

[42]  Piero Tortoli,et al.  Density-tapered spiral arrays for ultrasound 3-D imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[43]  Mustafa Karaman,et al.  Micromachined capacitive transducer arrays for intravascular ultrasound , 2005, SPIE MOEMS-MEMS.

[44]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.