Axial forces and bending moments in the loaded rabbit tibia in vivo

BackgroundDifferent animal models are used as fracture models in orthopaedic research prior to implant use in humans, although biomechanical forces can differ to a great extend between species due to variable anatomic conditions, particularly with regard to the gait. The rabbit is an often used fracture model, but biomechanical data are very rare. The objective of the present study was to measure axial forces, bending moments, and bending axis directly in the rabbit tibia in vivo. The following hypothesis was tested: Axial forces and bending moments in the mid-diaphysis of rabbit tibia differ from other experimental animals or indirectly calculated data.MethodsA minifixateur system with 4 force sensors was developed and attached to rabbit tibia (n = 4), which were subsequently ostectomised. Axial forces, bending moments and bending angles were calculated telemetrically during weight bearing in motion between 6 and 42 days post operation.ResultsHighest single values were 201% body weight [% bw] for axial forces and 409% bw cm for bending moments. Whereas there was a continous decrease in axial forces over time after day 10 (P = 0.03 on day 15), a decrease in bending moments was inconsistent (P = 0.03 on day 27). High values for bending moments were frequently, but not consistently, associated with high values for axial forces.ConclusionAxial forces in rabbit tibia exceeded axial forces in sheep, and differed from indirectly calculated data. The rabbit is an appropriate fracture model because axial loads and bending moments in rabbit tibia were more closely to human conditions than in sheep tibia as an animal model.

[1]  Yuehuei H. An,et al.  Animal Models in Orthopaedic Research , 1999 .

[2]  H. Uhthoff,et al.  Current concepts of internal fixation of fractures. , 1980, Canadian journal of surgery. Journal canadien de chirurgie.

[3]  P. Paavolainen,et al.  Fracture repair during external fixation. Torsion tests of rabbit osteotomies. , 1987, Acta orthopaedica Scandinavica.

[4]  J. Newman The prevention of infection in open fractures. , 1983, The Journal of antimicrobial chemotherapy.

[5]  G. Duda,et al.  Muskuloskeletale Belastungen im Schafshinterlauf: Mechanische Rahmenbedingungen der Heilung , 2005 .

[6]  M. Gomez-Benito,et al.  Monitoring In Vivo Load Transmission Through an External Fixator , 2010, Annals of Biomedical Engineering.

[7]  K Seide,et al.  Three-dimensional load measurements in an external fixator. , 2004, Journal of biomechanics.

[8]  William R Taylor,et al.  Tibio‐femoral loading during human gait and stair climbing , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  Henning Windhagen,et al.  In Vivo Corrosion of Two Novel Magnesium Alloys ZEK100 and AX30 and Their Mechanical Suitability as Biodegradable Implants , 2011, Materials.

[10]  F. Forriol,et al.  Mechanical analysis of the healing of different osteotomies fixed externally , 2000, International Orthopaedics.

[11]  R. G. Richards,et al.  Animal models for implant biomaterial research in bone: a review. , 2007, European cells & materials.

[12]  P O Hutzschenreuter,et al.  Loads on Muscles, Tendons and Bones in the Hind Extremities of Sheep – A Theoretical study * , 1993, Anatomia, histologia, embryologia.

[13]  Silke Besdo,et al.  Determination of dynamically adapting anisotropic material properties of bone under cyclic loading. , 2011, Journal of biomechanics.

[14]  P. Paavolainen,et al.  Different healing patterns of experimental osteotomies treated by intramedullary nailing , 2004, Archives of Orthopaedic and Trauma Surgery.

[15]  P. Lesker,et al.  Improved healing of experimental long bone fractures in rabbits by delayed internal fixation. , 1975, The Journal of trauma.

[16]  Jeff Houck,et al.  Rabbit knee joint biomechanics: Motion analysis and modeling of forces during hopping , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  P. Worlock,et al.  The prevention of infection in open fractures. An experimental study of the effect of antibiotic therapy. , 1988, The Journal of bone and joint surgery. American volume.

[18]  T. Terjesen,et al.  Effects of fixation stiffness on fracture healing. External fixation of tibial osteotomy in the rabbit. , 1986, Acta orthopaedica Scandinavica.

[19]  O. Böstman,et al.  Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. , 1992, The Journal of bone and joint surgery. American volume.

[20]  J. Spadaro,et al.  Bone growth after osteotomy and internal fixation in young rabbits , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[21]  J. L. Cunningham,et al.  Monitoring the Mechanical Properties of Healing Bone , 2009, Clinical orthopaedics and related research.

[22]  P. Paavolainen,et al.  Fracture repair during external fixation , 1987 .

[23]  Lutz Claes,et al.  Internal loads in the human tibia during gait. , 2009, Clinical biomechanics.

[24]  Fritz Thorey,et al.  Telemetric in vivo measurement of compressive forces during consolidation in a rabbit model. , 2011, Technology and health care : official journal of the European Society for Engineering and Medicine.