Bileaflet Aortic Valve Prosthesis Pivot Geometry Influences Platelet Secretion and Anionic Phospholipid Exposure

AbstractThe clinical histories of the Medtronic Parallel (MP) and St. Jude Medical (SJM) Standard valves suggest pivot geometry influences the thrombogenic characteristics of bileaflet prostheses. This work studied the effects of various pivot geometries on markers of platelet damage in a controlled, in vitro apparatus. The Medtronic Parallel valve, two St. Jude Medical valves, and two demonstration prostheses were used to study the effects of bileaflet pivot design, gap width, and size on platelet secretion and anionic phospholipid expression during leakage flow. A centrifugal pump was used to drive blood through a circuit containing a bileaflet prosthesis. Samples were taken at set time intervals after the start of the pump. These samples were analyzed by cell counting, flow cytometry, and enzyme-linked immunosorbant assay. No significant differences were observed in platelet secretion or anionic phospholipid expression between experiments with the SJM 27 Standard regular leaker, the SJM 20 regular leaker, and the MP 27 valves. Significant differences in platelet secretion and anionic phospholipid expression were observed between a SJM 27 Standard regular leaker and a SJM 27 high leaker valve. These studies suggest that leakage gap width within bileaflet valve pivots has a significant effect on platelet damage initiated by leakage flow. © 2001 Biomedical Engineering Society. PAC01: 8719Uv, 8719Tt, 8380Lz, 8768+z

[1]  H N Sabbah,et al.  Measured Turbulence and Its Effect on Thrombus Formation , 1974, Circulation research.

[2]  A P Yoganathan,et al.  The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus. , 2001, The Journal of heart valve disease.

[3]  D. Lawler Physical Aspects of Flocculation: From Microscale to Macroscale , 1993 .

[4]  A P Yoganathan,et al.  Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing. , 1996, The Journal of heart valve disease.

[5]  P K Paulsen,et al.  Hemodynamic evaluation of a new bileaflet valve prosthesis: an acute animal experimental study. , 1996, The Journal of heart valve disease.

[6]  H Schmid-Schönbein,et al.  Towards a concept of thrombosis in accelerated flow: rheology, fluid dynamics, and biochemistry. , 1985, Biorheology.

[7]  M S Croughan,et al.  Hydrodynamic effects on animal cells grown in microcarrier cultures , 1987, Biotechnology and bioengineering.

[8]  A P Yoganathan,et al.  An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. , 1996, The Journal of heart valve disease.

[9]  H. Goldsmith,et al.  Aggregation of human platelets in an annular vortex distal to a tubular expansion. , 1979, Microvascular research.

[10]  Ajit P. Yoganathan,et al.  Visualization of the hinge flow in a 5:1 scaled model of the medtronic parallel bileaflet heart valve prosthesis , 1998 .

[11]  Win Aung,et al.  Starting Flow and Heat Transfer Downstream of a Backward-Facing Step , 1991 .

[12]  E. Leonard,et al.  Separated flows in artificial organs. A cause of early thrombogenesis? , 1996, ASAIO journal.

[13]  A P Yoganathan,et al.  A microstructural flow analysis within a bileaflet mechanical heart valve hinge. , 1996, The Journal of heart valve disease.

[14]  Yun Zheng,et al.  TURBULENT FLOW OVER STEP WITH ROUNDED EDGES: EXPERIMENTAL AND NUMERICAL STUDY , 2000 .