A combined, large, multi-faceted bulbous façade glazed curtain with open atrium as a natural ventilation solution for an energy efficient sustainable office building in Southern China

This paper investigates the ventilation performance of a stack system built with a bulbous façade glazed curtain and an open atrium in a six-storey office building, in DongGuan eco-park in southern China. Sustainable development, energy efficiency, indoor environmental quality and thermal comfort are the key criteria for the design; incorporating LingNan architectural cultural elements, with large open atrium for natural ventilation and openable windows to allow air movement throughout the building. The high energy load accentuated by the glazing would be offset by stack ventilation, to provide indoor circulation of air to maintain a satisfactory level of thermal comfort in spring/autumn, without relying on air conditioning, thus saving energy consumption (about 60%). Computational Fluid Dynamics (CFD) simulations were conducted to determine the efficacy of natural ventilation to illustrate the heat storage, dissipation and transfer within the building. The ventilation and heat dissipation performance of the stack system in the bulbous atrium in different seasons are illustrated with four different percentage of inlet and outlet openings. In summer and autumn/spring, good natural ventilation performance in the building can be achieved by the bulbous façade layer caused by buoyancy force and wind pressure and in the atrium courtyard. Sound ventilation performance can be achieved in rooms on most floors, while worst ventilation performance is expected in the top floor. The design of the bulbous façade with a large open atrium can provide effective ventilation efficiency for a better indoor thermal environment by strategic use of building self-shading and natural ventilation.

[1]  Norhayati Mahyuddin,et al.  Thermal performance of atria: An overview of natural ventilation effective designs , 2014 .

[2]  Matthias Haase,et al.  Double-skin facades for Hong Kong , 2008 .

[3]  Stephen Selkowitz,et al.  High-performance commercial building facades , 2002 .

[4]  Jeong Tai Kim,et al.  Overall Environmental Modelling of Newly Designed Curtain Wall Façade Configurations , 2013 .

[5]  Ali GhaffarianHoseini,et al.  Sustainable energy performances of green buildings: a review of current theories, implementations and challenges , 2013 .

[6]  Jie Zhu,et al.  Review of passive solar heating and cooling technologies , 2010 .

[7]  Richard Saxon Atrium Buildings: Development and Design , 1983 .

[8]  Ban-Huat Ng,et al.  Energy-Efficient Buildings: An In-Depth Look into Definitions, and Design Problems , 2013 .

[9]  Philipp Rode,et al.  Cities and Energy: Urban Morphology and Residential Heat-Energy Demand , 2014 .

[10]  Chuck Yu,et al.  Towards “Zero-Carbon Homes” – Issues of Thermal Comfort , 2012 .

[11]  Per Heiselberg,et al.  Designing with Responsive Building Elements , 2011 .

[12]  Chuck Yu,et al.  Low-Carbon Housings and Indoor Air Quality , 2012 .

[13]  Svetlana Pushkar,et al.  A methodology for design of environmentally optimal buildings by variable grouping , 2005 .

[14]  Chuck Yu,et al.  Regression Analysis of the Relationship between Urban Heat Island Effect and Urban Canopy Characteristics in a Mountainous City, Chongqing , 2012 .

[15]  Brian Launder,et al.  Second-moment closure: present… and future? , 1989 .

[16]  Aslihan Tavil,et al.  THERMAL PERFORMANCE SIMULATION OF AN ATRIUM BUILDING , 2006 .

[17]  Sungho Lee,et al.  A Lifecycle Health Performance Tree for Sustainable Healthy Buildings , 2012 .

[18]  Yuehong Su,et al.  A review on wind driven ventilation techniques , 2008 .

[19]  Giorgio Baldinelli,et al.  Double skin facades for warm climate regions : Analysis of a solution with an integrated movable shading system , 2009 .

[20]  Fergus Nicol,et al.  Post-occupancy evaluation and field studies of thermal comfort , 2005 .

[21]  Qinglin Meng,et al.  Thermal comfort in naturally ventilated buildings in hot-humid area of China , 2010 .

[22]  Andreas Wagner,et al.  Thermal comfort and workplace occupant satisfaction—Results of field studies in German low energy office buildings , 2007 .

[23]  Husrul Nizam Husin,et al.  Post Occupancy Evaluation towards Indoor Environment Improvement in Malaysia’s Office Buildings , 2009 .

[24]  Tommy Kleiven,et al.  Natural ventilation in buildings : architectural concepts, consequences and possibilities , 2003 .

[25]  S. Iniyan,et al.  A review of solar thermal technologies , 2010 .

[26]  Derek Clements-Croome,et al.  Natural ventilation in non-domestic buildings , 2005 .

[27]  Jeong Tai Kim,et al.  Building Environmental Assessment Schemes for Rating of IAQ in Sustainable Buildings , 2011 .

[28]  F. Carrié,et al.  Thermal and ventilation modelling of large highly-glazed spaces , 2001 .

[29]  Rasmus Lund Jensen,et al.  Experimental Analysis and Model Validation of an Opaque Ventilated Facade , 2012 .

[30]  Yong Xiang,et al.  Commercial building energy use in six cities in Southern China , 2013 .

[31]  Jørn Toftum,et al.  Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings , 2007 .

[32]  Abdelsalam Aldawoud,et al.  Comparative analysis of energy performance between courtyard and atrium in buildings , 2008 .

[33]  Nazli Bin Che Din,et al.  Thermal and acoustic environmental requirements for green buildings in Malaysia , 2012 .

[34]  Harris Poirazis,et al.  Double Skin Facades for Office Buildings - Literature Review Report , 2004 .

[35]  Lena Vogler,et al.  Sustainable Construction Green Building Design And Delivery , 2016 .

[36]  R. Velraj,et al.  Passive cooling methods for energy efficient buildings with and without thermal energy storage - A review , 2012 .

[37]  Derek Clements-Croome,et al.  Sustainable building solutions: a review of lessons from the natural world , 2005 .

[38]  Sebastian Herkel,et al.  Design, monitoring and evaluation of a low energy office building with passive cooling by night ventilation , 2004 .

[39]  Erik L Olsen,et al.  Energy consumption and comfort analysis for different low-energy cooling systems in a mild climate , 2003 .

[40]  Jn Hacker,et al.  Beating the heat: Keeping UK buildings cool in a warmer climate , 2005 .

[41]  Jeong Tai Kim,et al.  Development of a Double-Skin Façade for Sustainable Renovation of Old Residential Buildings , 2013 .

[42]  Amanjeet Singh,et al.  Effects of green buildings on employee health and productivity. , 2010, American journal of public health.

[43]  Kuala Lumpur OCCUPANT SATISFACTION IN RESPECT TO INDOOR ENVIRONMENTAL QUALITY IN ENERGY EFFICIENT CERTIFIED BUILDINGS IN MALAYSIA , 2010 .