A three phase DSTATCOM compensating AC and DC loads with fast dynamic response

The paper discusses a DSTATCOM topology for compensating ac loads in the three-phase, four-wire systems as well as supplying dc loads from its dc link. Its state space modeling is presented. The transient response of the compensator is very important while compensating dynamically varying loads. Any change in the load affects the dc link voltage directly. Generally, a closed loop proportional integral controller is used to maintain the dc link voltage which has slow transient response. To achieve a good dynamic response, a fast acting dc link voltage controller is proposed. Mathematical equations are given to design the controller parameters. A digital simulation study using MATLAB, is carried out to demonstrate the performance of the proposed fast acting dc link voltage controller over the conventional one.

[1]  Arindam Ghosh,et al.  A new STATCOM topology to compensate loads containing AC and DC components , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[2]  Kamal Al-Haddad,et al.  Design, simulation and implementation of three-pole/four-pole topologies for active filters , 2004 .

[3]  Ned Mohan,et al.  Active filtering of harmonic currents in three-phase, four-wire systems with three-phase and single-phase nonlinear loads , 1992, [Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition.

[4]  A. S. Kislovski,et al.  Telecom power supplies and power quality , 1995, Proceedings of INTELEC 95. 17th International Telecommunications Energy Conference.

[5]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[6]  Arindam Ghosh,et al.  A new approach to load balancing and power factor correction in power distribution system , 2000 .

[7]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[8]  Mauricio Aredes,et al.  Three-phase four-wire shunt active filter control strategies , 1997 .

[9]  P.N. Enjeti,et al.  Three phase active harmonic rectifier (AHR) to improve utility input current THD in telecommunication power distribution system , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[10]  P. Mehta,et al.  Active power filters: a review , 2000 .

[11]  Arindam Ghosh,et al.  Inverter topologies for DSTATCOM applications—a simulation study , 2005 .

[12]  A. S. Kislovski Telecom Power-supply Plants Using Three-phase Rectifiers And Active Filters , 1997, The Second International Telecommunications Energy Special Conference.