Measurement of erythrocyte membrane elasticity by flicker eigenmode decomposition.

We have studied the flickering of erythrocytes at wavelengths comparable to the cell dimension. To do this we have analyzed the edge fluctuations of the cell to a resolution of 5 nm by combining phase contrast microscopy with fast image processing. By measuring the edge excitations simultaneously at four orthogonal positions around the cell, the eigenmodes of equal azimuthal mode numbers m = 0,1,2 could be separated. From a continuous time sequence of 100 s of video frames taken at 40 ms time intervals, we determined the time-auto correlation function for the modes m = 0,1,2 and calculated their mean square amplitudes as well as their decay times tau m. To explain the results we also present the theoretically calculated energy eigenmodes of an erythrocyte, accounting for the constraint that the cell is in contact with the substrate along an annular ring, which agreed well with the experimental findings. We found that the softest mode is a "hindered translational" mode with m = 1 of the adhered cell, which is almost insensitive to the shear elastic modulus. Comparison of the calculated and measured amplitudes yielded an average value for the bending stiffness of kc = 4 x 10(-19) J, which is much larger than the value obtained by flicker analysis at short wavelengths (kc = 2.3 x 10(-20) J). It would, however, agree well with the value expected from the red cell membrane area compressibility modulus of K = 4.5 x 10(-1)N/m, which corresponds to a lipid bilayer containing approximately 50 mol % of cholesterol. In contradiction to our theoretical expectations we found that the flicker eigenmodes seemed not to be influenced by the membrane shear elasticity, which will be discussed in terms of an unusual coupling between the lipid bilayer and the cytoskeleton.

[1]  I. Bivas,et al.  Bending elasticity and thermal fluctuations of lipid membranes. Theoretical and experimental requirements , 1989 .

[2]  T. Fischer Is the surface area of the red cell membrane skeleton locally conserved? , 1992, Biophysical journal.

[3]  M. Stöhr,et al.  Selective alteration of erythrocyte deformabiliby by SH-reagents: evidence for an involvement of spectrin in membrane shear elasticity. , 1978, Biochimica et biophysica acta.

[4]  R M Hochmuth,et al.  Measurement of the elastic modulus for red cell membrane using a fluid mechanical technique. , 1973, Biophysical journal.

[5]  Christoph F. Schmidt,et al.  Conformation and elasticity of the isolated red blood cell membrane skeleton. , 1992, Biophysical journal.

[6]  A. Mikkelsen,et al.  The human erythrocyte membrane skeleton may be an ionic gel , 1986, European Biophysics Journal.

[7]  R. Waugh,et al.  Thermoelasticity of red blood cell membrane. , 1979, Biophysical journal.

[8]  A. Mikkelsen,et al.  The human erythrocyte membrane skeleton may be an ionic gel , 1986, European Biophysics Journal.

[9]  E. Evans,et al.  Molecular maps of red cell deformation: hidden elasticity and in situ connectivity. , 1994, Science.

[10]  Erich Sackmann,et al.  Bending elastic moduli of lipid bilayers : modulation by solutes , 1990 .

[11]  Erich Sackmann,et al.  Theoretical and phase contrast microscopic eigenmode analysis of erythrocyte flicker : amplitudes , 1992 .

[12]  V. Bennett,et al.  Spectrin-based membrane skeleton: a multipotential adaptor between plasma membrane and cytoplasm. , 1990, Physiological reviews.

[13]  E. Evans Bending elastic modulus of red blood cell membrane derived from buckling instability in micropipet aspiration tests. , 1983, Biophysical journal.

[14]  D. Boal,et al.  Computer simulation of a model network for the erythrocyte cytoskeleton. , 1994, Biophysical journal.

[15]  R. Waugh,et al.  Osmotic correction to elastic area compressibility measurements on red cell membrane. , 1977, Biophysical journal.

[16]  The human erythrocyte membrane skeleton may be an ionic gel. III. Micropipette aspiration of unswollen erythrocytes. , 1986 .

[17]  L. Reichl A modern course in statistical physics , 1980 .

[18]  S Inoué,et al.  Imaging of unresolved objects, superresolution, and precision of distance measurement with video microscopy. , 1989, Methods in cell biology.

[19]  M. Peterson Geometrical methods for the elasticity theory of membranes , 1985 .

[20]  E. Sackmann,et al.  On the measurement of shear elastic moduli and viscosities of erythrocyte plasma membranes by transient deformation in high frequency electric fields. , 1988, Biophysical journal.

[21]  M. Kozlov,et al.  Model of red blood cell membrane skeleton: electrical and mechanical properties. , 1987, Journal of theoretical biology.

[22]  Wilfred D. Stein,et al.  Cell Shape: Determinants, Regulation, and Regulatory Role , 1989 .

[23]  M. Kozlov,et al.  Mechanical properties of the red cell membrane skeleton: analysis of axisymmetric deformations. , 1988, Journal of theoretical biology.

[24]  R. Lipowsky,et al.  The Structure and Conformation of Amphiphilic Membranes , 1992 .

[25]  L. Derick,et al.  Visualization of the hexagonal lattice in the erythrocyte membrane skeleton , 1987, The Journal of cell biology.

[26]  W. Helfrich,et al.  Undulations, steric interaction and cohesion of fluid membranes , 1984 .

[27]  Sackmann,et al.  Spectral analysis of erythrocyte flickering in the 0.3-4- microm-1 regime by microinterferometry combined with fast image processing. , 1992, Physical review. A, Atomic, molecular, and optical physics.

[28]  F. Brochard,et al.  Frequency spectrum of the flicker phenomenon in erythrocytes , 1975 .

[29]  Seifert,et al.  Adhesion of vesicles. , 1990, Physical review. A, Atomic, molecular, and optical physics.

[30]  H. Meiselman,et al.  Geometric, osmotic, and membrane mechanical properties of density-separated human red cells. , 1982, Blood.