Transients in reactors for power systems compensation

This thesis describes new models and investigations into switching transient phenomena related to the shunt reactors and the Mechanically Switched Capacitor with Damping Network (MSCDN) operations used for reactive power control in the transmission system. Shunt reactors and MSCDN are similar in that they have reactors. A shunt reactor is connected parallel to the compensated lines to absorb the leading current, whereas the MSCDN is a version of a capacitor bank that has been designed as a C-type filter for use in the harmonic-rich environment. In this work, models have been developed and transient overvoltages due to shunt reactor deenergisation were estimated analytically using MathCad, a mathematical program. Computer simulations were then undertaken using the ATP/EMTP program to reproduce both single-phase and three-phase shunt reactor switching at 275 kV operational substations. The effect of the reactor switching on the circuit breaker grading capacitor was also examined by considering various switching conditions. The main original achievement of this thesis is the clarification of failure mechanisms occurring in the air-core filter reactor due to MSCDN switching operations. The simulation of the MSCDN energisation was conducted using the ATP/EMTP program in the presence of surge arresters. The outcome of this simulation shows that extremely fast transients were established across the air-core filter reactor. This identified transient event has led to the development of a detailed air-core reactor model, which accounts for the inter-turn RLC parameters as well as the stray capacitances-to-ground. These parameters are incorporated into the transient simulation circuit, from which the current and voltage distribution across the winding were derived using electric field and equivalent circuit modelling. Further analysis of the results has revealed that there are substantial dielectric stresses imposed on the winding insulation that can be attributed to a combination of three factors. (i) First, the surge arrester operation during the MSCDN energisation, which causes steep voltage change at the reactor terminal. (ii) Second, the nonuniform voltage distribution, resulting in high stresses across the top inter-turn windings. (iii) Third, the rapid rate-of-change of voltage in the assumed worst-case reactor winding location. This is accompanied by a high dielectric (displacement) current through the inter-turn winding insulation. Work within this investigation proposes that a synergistic effect of high electric field and high dielectric current occurring at worst energisation, followed by the thermal effects of steady state operation contributes to the failure of air-core reactors used on the 400 kV MSCDN.

[1]  Mathias Enohnyaket,et al.  PEEC Modeling and Verification for Broadband Analysis of Air-Core Reactors , 2007 .

[2]  F. de Leon,et al.  Efficient calculation of elementary parameters of transformers , 1992 .

[3]  László Prikler EMTP models for simulation of shunt reactor switching transients , 1997 .

[4]  A. Kalyuzhny,et al.  Analytical Study of Voltage Magnification Transients Due to Capacitor Switching , 2009, IEEE Transactions on Power Delivery.

[5]  J. Kuffel,et al.  High Voltage Engineering: Fundamentals , 1984 .

[6]  D. F. Peelo,et al.  A new IEEE Application Guide for Shunt Reactor Switching , 1996 .

[7]  Y. H. Fu Simulation Study On The Switching Transients during de-generation of Filter And Capacitor Banks , 1996 .

[8]  Yao Xiao,et al.  Theory for the design of C-type filter , 2004, 2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951).

[9]  R. Sastry Vedam,et al.  Power Quality: VAR Compensation in Power Systems , 2008 .

[10]  Xifan Wang,et al.  Energization transients of shunt reactors , 1997 .

[11]  Ieee Pc Draft Standard Requirements,Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors , 2010 .

[12]  F.W. Grover Formulas and Tables for the Calculation and Design of Single-Layer Coils , 1924, Proceedings of the Institute of Radio Engineers.

[13]  J. Bird Electrical Circuit Theory and Technology , 2007 .

[14]  C. Mayoux,et al.  Degradation of insulating materials under electrical stress , 2000 .

[15]  P. Auriol,et al.  Dielectric losses in power transformers under high frequency transients , 1992, Conference Record of the 1992 IEEE International Symposium on Electrical Insulation.

[16]  A. Haddad,et al.  Transient analysis during switching of mechanically switched capacitor and damping network (MSCDN) , 2010, 45th International Universities Power Engineering Conference UPEC2010.

[17]  雨谷 昭弘 Alternative transients program rule book , 1989 .

[18]  Liana Mirela Cipcigan,et al.  Analysing a 400 kV power system for an expert system switching , 2000, 2000 10th Mediterranean Electrotechnical Conference. Information Technology and Electrotechnology for the Mediterranean Countries. Proceedings. MeleCon 2000 (Cat. No.00CH37099).

[19]  N.D. Hatziargyriou,et al.  Control of shunt reactor inrush currents in the Hellenic-Interconnected Power System , 2005, IEEE Transactions on Power Delivery.

[20]  A. Haddad,et al.  Determination of transient overvoltages during shunt reactor deenergization , 2009, 2009 44th International Universities Power Engineering Conference (UPEC).

[21]  A. A. Dahab,et al.  A complete model of a single layer air-cored reactor for impulse voltage distribution , 1988 .

[22]  Hermann W. Dommel,et al.  Digital Computer Solution of Electromagnetic Transients in Single-and Multiphase Networks , 1969 .

[23]  R. C. Campos,et al.  Mechanically Switched Capacitor with Damping Network (MSCDN) - Engineering aspects of application, design and protection , 2010, 2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA).

[24]  Paul Coventry,et al.  Electrical stresses on circuit‐breaker voltage grading capacitors caused by unequal voltage sharing during switching operations , 2011 .

[25]  PÄR HOLMBERG ACTA UNIVERSITATIS UPSALIENSIS UPPSALA Modelling the Transient Response of Windings , Laminated Steel Cores and Electromagnetic Power Devices by Means of Lumped Circuits , 2000 .

[26]  J. Enon,et al.  Investigation of the failure mechanism of insulation subjected to repetitive fast voltage surges , 1997, Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference.

[27]  R. Kasturi,et al.  Computation of impulse-voltage stresses in transformer windings , 1979 .

[28]  D. Jefferies Developing the highways of power [National Grid Company, transmission] , 1997 .

[30]  Sandra Hutter,et al.  Transients Due to Switching of 400 kV Shunt Reactor , 2001 .

[31]  M. R. Sharp,et al.  Selecting ratings for capacitors and reactors in applications involving multiple single-tuned filters , 1995 .

[32]  Arieh L. Shenkman,et al.  Transient Analysis of Electric Power Circuits Handbook , 2005 .

[33]  N. Hylten-Cavallius,et al.  Capacitance calculations for some basic high voltage electrode configurations , 1975, IEEE Transactions on Power Apparatus and Systems.

[34]  S. A. Khaparde,et al.  Transformer Engineering: Design and Practice , 2004 .

[35]  Cheng Shukang,et al.  Research on turn-to-turn insulation test method of dry-type air-core reactor , 2000, Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials (Cat. No.00CH36347).

[36]  D. F. Peelo,et al.  Shunt reactor switching tests in BC Hydro's 500 kV system , 1988 .

[37]  Marjan Popov,et al.  Modelling, simulation and measurement of fast transients in transformer windings with consideration of frequency-dependent losses , 2007 .

[38]  Ziming Su,et al.  Based on the BEM of Internal Electric Field Simulation of Shunt Dry Reactor , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[39]  J. McWhirter,et al.  Calculation of impulse voltage stresses in transformer windings , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[40]  Frederick Warren Grover,et al.  Inductance Calculations: Working Formulas and Tables , 1981 .

[41]  Beryl M. Dent,et al.  A method of analysis of transformer impulse voltage distribution using a digital computer , 1958 .

[42]  Pär Holmberg Modelling the transient response of windings, laminated steel coresand electromagnetic power devices by means of lumped circuits : With special reference to windings with a coaxial insulation system , 2000 .

[43]  Marjan Popov,et al.  Analysis of Voltage Distribution in Transformer Windings During Circuit Breaker Prestrike , 2009 .

[44]  P. E. Burke,et al.  The Accurate Computation of Self and Mutual Inductances of Circular Coils , 1978, IEEE Transactions on Power Apparatus and Systems.

[45]  A. El-Morshedy,et al.  Insulation failure assessment under random energization overvoltages , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[46]  J. H. Schuld,et al.  Impact of reactive power compensation equipment on the harmonic impedance of high voltage networks , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[47]  S. L. Varricchio,et al.  Electrical strength in air core reactors , 1994, Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM).

[48]  Magdy M. A. Salama A Calcualtion Method for Voltage Distribution in a Large AIR Core Power Reactor , 1981 .

[49]  R. Schifani,et al.  Effects of 3rd-harmonic voltage content on dielectric losses of solid insulating materials , 1981 .

[50]  R. Bruetsch High Voltage Insulation Failure Mechanisms , 2008, Conference Record of the 2008 IEEE International Symposium on Electrical Insulation.

[51]  M. Kizilcay,et al.  Flashovers at a 33-kV filter reactor during energization , 2007 .

[52]  Abderrahmane Haddad,et al.  Overvoltages and insulation coordination on transmission networks , 2004 .

[53]  Jian Yu,et al.  Electric Field Analysis of Air Core Power Reactor , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[54]  Chao-Rong Chen,et al.  Comparison of transient phenomena when switching shunt reactors on the line's two terminals and station busbar , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[55]  N.M. MacLeod,et al.  The control of harmonic distortion on an EHV system by the use of capacitive damping networks , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[56]  M.M.A. Salama,et al.  Calculation of Steady-State Surface at Winding Ends of Air-Core Power Reactors , 1981, IEEE Transactions on Power Apparatus and Systems.