Considerations in the sterile manufacture of polymeric microneedle arrays

AbstractWe describe, for the first time, considerations in the sterile manufacture of polymeric microneedle arrays. Microneedles (MN) made from dissolving polymeric matrices and loaded with the model drugs ovalbumin (OVA) and ibuprofen sodium and hydrogel-forming MN composed of “super-swelling” polymers and their corresponding lyophilised wafer drug reservoirs loaded with OVA and ibuprofen sodium were prepared aseptically or sterilised using commonly employed sterilisation techniques. Moist and dry heat sterilisation, understandably, damaged all devices, leaving aseptic production and gamma sterilisation as the only viable options. No measureable bioburden was detected in any of the prepared devices, and endotoxin levels were always below the US Food & Drug Administration limits (20 endotoxin units/device). Hydrogel-forming MN were unaffected by gamma irradiation (25 kGy) in terms of their physical properties or capabilities in delivering OVA and ibuprofen sodium across excised neonatal porcine skin in vitro. However, OVA content in dissolving MN (down from approximately 101.1 % recovery to approximately 58.3 % recovery) and lyophilised wafer-type drug reservoirs (down from approximately 99.7 % recovery to approximately 60.1 % recovery) was significantly reduced by gamma irradiation, while the skin permeation profile of ibuprofen sodium from gamma-irradiated dissolving MN was markedly different from their non-irradiated counterparts. It is clear that MN poses a very low risk to human health when used appropriately, as evidenced here by low endotoxin levels and absence of microbial contamination. However, if guarantees of absolute sterility of MN products are ultimately required by regulatory authorities, it will be necessary to investigate the effect of lower gamma doses on dissolving MN loaded with active pharmaceutical ingredients and lyophilised wafers loaded with biomolecules in order to avoid the expense and inconvenience of aseptic processing. Graphical AbstractConcept map for the sterile manufacture of polymeric microneedle arrays and lyophilised wafers

[1]  S. Girois,et al.  Polym. Degrad. Stab. , 1996 .

[2]  V. Stannett,et al.  Mobility as a mechanism for radiation stabilization of polypropylene , 1982 .

[3]  Ryan F. Donnelly,et al.  Microneedle-mediated Transdermal and Intradermal Drug Delivery , 2012 .

[4]  M. Garland,et al.  Laser-Engineered Dissolving Microneedle Arrays for Transdermal Macromolecular Drug Delivery , 2011, Pharmaceutical Research.

[5]  Ryan F. Donnelly,et al.  Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro , 2009, Pharmaceutical Research.

[6]  M. Silindir,et al.  Sterilization Methods and the Comparison of E-Beam Sterilization with Gamma Radiation Sterilization , 2011 .

[7]  P. McCarron,et al.  Investigation of swelling and network parameters of poly(ethylene glycol)-crosslinked poly(methyl vinyl ether-co-maleic acid) hydrogels , 2009 .

[8]  R. Verger,et al.  Use of the tape stripping technique for directly quantifying esterase activities in human stratum corneum. , 2001, Analytical biochemistry.

[9]  Ryan F. Donnelly,et al.  Microneedle-Mediated Transdermal and Intradermal Drug Delivery: Donnelly/Microneedle-Mediated Transdermal and Intradermal Drug Delivery , 2012 .

[10]  M. Sinclair,et al.  Color center annealing in γ - irradiated polystyrene, under vacuum and air atmospheres , 1993 .

[11]  K. Gillen,et al.  Color formation in irradiated polymers , 1996 .

[12]  K. Gillen,et al.  Dose-rate dependence of the radiation-induced discoloration of polystyrene , 1993 .

[13]  M. Sinclair,et al.  Discoloration and subsequent recovery of optical polymers exposed to ionizing radiation , 1995 .

[14]  Ryan F. Donnelly,et al.  Design and physicochemical characterisation of novel dissolving polymeric microneedle arrays for transdermal delivery of high dose, low molecular weight drugs , 2014, Journal of controlled release : official journal of the Controlled Release Society.

[15]  Conor O'Mahony,et al.  Hydrogel-forming microneedle arrays exhibit antimicrobial properties: potential for enhanced patient safety. , 2013, International journal of pharmaceutics.

[16]  Conor O'Mahony,et al.  Processing difficulties and instability of carbohydrate microneedle arrays , 2009, Drug development and industrial pharmacy.

[17]  M. Gahleitner,et al.  STERILIZATION EFFECTS ON POLYPROPYLENE: TECHNOLOGY AND POLYMER TYPE EFFECTS , 2003 .

[18]  Ryan F. Donnelly,et al.  Design, Optimization and Characterisation of Polymeric Microneedle Arrays Prepared by a Novel Laser-Based Micromoulding Technique , 2010, Pharmaceutical Research.

[19]  P. Klemchuk Protecting polymers against damage from gamma radiation , 1993 .

[20]  Thakur Raghu Raj Singh,et al.  Hydrogel-Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery , 2012, Advanced functional materials.

[21]  Maelíosa T. C. McCrudden,et al.  Laser‐engineered dissolving microneedle arrays for protein delivery: potential for enhanced intradermal vaccination , 2015, The Journal of pharmacy and pharmacology.

[22]  A. Kissenpfennig,et al.  Microneedle-mediated vaccine delivery: Harnessing cutaneous immunobiology to improve efficacy , 2012, Expert opinion on drug delivery.