Low input coil inductance SQUIDs for cryogenic current comparator applications

Dc SQUIDs with an optimal input coil inductance have been developed for a Cryogenic Current Comparator (CCC) that is used for the calibration of electrical standards. We studied a series of SQUIDs with input inductances in the range from 20-160 nH. The electrical properties like input current noise and flux to voltage transfer have been investigated. The CCC is an overlapping tube configuration and the tube itself is used as the pick-up coil of the flux transformer circuit of the SQUID. The coupling between CCC and flux transformer is in this case ideal and should have an optimal value when the effective overlapping tube inductance, typically in the range from 10-100 nH, equals that of the SQUID input coil (flux transformer theory). To compare with theory, sensitivity measurements on the SQUID-CCC have been performed in a special set-up where the effective overlapping tube inductance can be modified placing the CCC in a superconducting shield at various distances.

[1]  Gert Rietveld,et al.  Ultimate current resolution of a cryogenic current comparator , 1999, IEEE Trans. Instrum. Meas..

[2]  Jaap Flokstra,et al.  Fabrication of Nb/Al,AlOx/Al/Nb Josephson tunnel junctions using reactive ion etching in SF6 , 1993 .

[3]  J. Sese,et al.  CCC inductances calculation: validity of the image method , 1998, 1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254).

[4]  John Clarke,et al.  dc SQUID: Noise and optimization , 1977 .

[5]  J. Sese,et al.  Calculation of effective inductances of superconducting devices. Application to the cryogenic current comparator , 1999, IEEE Transactions on Applied Superconductivity.

[6]  Mark B. Ketchen,et al.  Planar coupling scheme for ultra low noise DC SQUIDs , 1981 .

[7]  I. K. Harvey A Precise Low Temperature dc Ratio Transformer , 1972 .

[8]  Gert Rietveld,et al.  Design and realization of an optimal current sensitive CCC , 1999, IEEE Trans. Instrum. Meas..

[9]  H. Seppa,et al.  The ratio error of the overlapped-tube cryogenic current comparator , 1990 .

[10]  A. W. Hamster,et al.  Two-stage amplifier based on a double relaxation oscillation superconducting quantum interference device , 1999 .

[11]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[12]  John Clarke,et al.  Impedance Matching a Josephson Galvanometer by Means of a Superconducting Transformer , 1971 .

[13]  Ronald F. Dziuba,et al.  Low temperature direct current comparators , 1974 .