Optimized three‐dimensional fast‐spin‐echo MRI

Spin‐echo‐based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio‐frequency or static field inhomogeneity. Three‐dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin‐echo‐based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin‐echo imaging have become available from several MR‐equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non–spatially selective radio‐frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio‐frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin‐echo train, these techniques permit single‐slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin‐echo pulse sequences provide a robust and flexible approach for 3D spin‐echo‐based imaging with a broad range of clinical applications. J. Magn. Reson. Imaging 2014;39:745–767. © 2014 Wiley Periodicals, Inc.

[1]  Heinrich Lanfermann,et al.  Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results , 2006, European Radiology.

[2]  Frank J Rybicki,et al.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses. , 2005, Medical physics.

[3]  R Marc Lebel,et al.  Intuitive design guidelines for fast spin echo imaging with variable flip angle echo trains , 2007, Magnetic resonance in medicine.

[4]  Juergen Hennig,et al.  Contrast behavior and relaxation effects of conventional and hyperecho‐turbo spin echo sequences at 1.5 and 3 T , 2006, Magnetic resonance in medicine.

[5]  James S Babb,et al.  Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: impact on artifacts and image quality. , 2010, AJR. American journal of roentgenology.

[6]  K. Scheffler,et al.  Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)‐algorithm: Principles and applications to hyperecho and TRAPS sequences , 2004, Magnetic resonance in medicine.

[7]  Philip J Beatty,et al.  Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. , 2007, AJR. American journal of roentgenology.

[8]  A. Tagliafico,et al.  Brachial plexus assessment with three-dimensional isotropic resolution fast spin echo MRI: comparison with conventional MRI at 3.0 T. , 2012, The British journal of radiology.

[9]  Dominik Paul,et al.  3D-imaging of the knee with an optimized 3D-FSE-sequence and a 15-channel knee-coil. , 2012, European journal of radiology.

[10]  John P. Mugler,et al.  Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque in Clinically Suspected Acute Transient Ischemic Attack and Acute Ischemic Stroke , 2010, Circulation.

[11]  John P Mugler,et al.  Optimized T1‐weighted contrast for single‐slab 3D turbo spin‐echo imaging with long echo trains: Application to whole‐brain imaging , 2007, Magnetic resonance in medicine.

[12]  James S Babb,et al.  Preliminary clinical experience at 3 T with a 3D T2-weighted sequence compared with multiplanar 2D for evaluation of the female pelvis. , 2011, AJR. American journal of roentgenology.

[13]  F A Jolesz,et al.  Partial RF echo‐planar imaging with the FAISE method. II. Contrast equivalence with spin‐echo sequences , 1992, Magnetic resonance in medicine.

[14]  Richard Kijowski,et al.  Routine 3D magnetic resonance imaging of joints , 2011, Journal of magnetic resonance imaging : JMRI.

[15]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[16]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[17]  Bob S. Hu,et al.  High‐resolution three‐dimensional in vivo imaging of atherosclerotic plaque , 1999, Magnetic resonance in medicine.

[18]  Suhyung Park,et al.  Phase‐sensitive, dual‐acquisition, single‐slab, 3D, turbo‐spin‐echo pulse sequence for simultaneous T2‐weighted and fluid‐attenuated whole‐brain imaging , 2010, Magnetic resonance in medicine.

[19]  Yong Eun Chung,et al.  Rectal cancer: comparison of accuracy of local-regional staging with two- and three-dimensional preoperative 3-T MR imaging. , 2010, Radiology.

[20]  Anja C. S. Brau,et al.  Volumetric fat-water separated T2-weighted MRI , 2011, Pediatric Radiology.

[21]  Mitsuru Ikeda,et al.  Contrast-enhanced MR imaging of metastatic brain tumor at 3 tesla: utility of T(1)-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence. , 2008, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[22]  Chun Yuan,et al.  Three‐dimensional fast spin‐echo imaging: Pulse sequence and in vivo image evaluation , 1993, Journal of magnetic resonance imaging : JMRI.

[23]  Richard Kijowski,et al.  Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation , 2012, Skeletal Radiology.

[24]  S-H Choi,et al.  Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences. , 2012, Clinical radiology.

[25]  Satoru Morita,et al.  Comparison of SPACE and 3D TSE MRCP at 1.5T focusing on difference in echo spacing. , 2009, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[26]  T. Ai,et al.  Diagnostic performance of CUBE MRI sequences of the knee compared with conventional MRI. , 2012, Clinical radiology.

[27]  Young Cheol Yoon,et al.  Qualitative and Quantitative Assessment of Isotropic Ankle Magnetic Resonance Imaging: Three-Dimensional Isotropic Intermediate-Weighted Turbo Spin Echo versus Three-Dimensional Isotropic Fast Field Echo Sequences , 2012, Korean journal of radiology.

[28]  J. Mugler,et al.  Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. , 2001, Radiology.

[29]  D M Kramer,et al.  Analysis of hybrid imaging techniques , 1992, Magnetic resonance in medicine.

[30]  Sung Tae Kim,et al.  Trigeminal neuralgia: Assessment with T2 VISTA and FLAIR VISTA fusion imaging , 2011, European Radiology.

[31]  Debiao Li,et al.  Carotid arterial wall MRI at 3T using 3D variable‐flip‐angle turbo spin‐echo (TSE) with flow‐sensitive dephasing (FSD) , 2010, Journal of magnetic resonance imaging : JMRI.

[32]  駒田 智大,et al.  Contrast-enhanced MR imaging of metastatic brain tumor at 3 tesla : utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence , 2009 .

[33]  Young Cheol Yoon,et al.  Qualitative and Quantitative Assessment of Wrist MRI at 3.0t: Comparison between Isotropic 3d Turbo Spin Echo and Isotropic 3D Fast Field Echo and 2D Turbo Spin Echo , 2013, Acta radiologica.

[34]  N. Lummel,et al.  3D Fluid-Attenuated Inversion Recovery Imaging: Reduced CSF Artifacts and Enhanced Sensitivity and Specificity for Subarachnoid Hemorrhage , 2011, American Journal of Neuroradiology.

[35]  F A Jolesz,et al.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. , 1990, Magnetic resonance imaging.

[36]  Jin Hwan Ahn,et al.  Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences. , 2009, Radiology.

[37]  Wilhelm Horger,et al.  Magnetic Resonance Imaging of the Body Trunk Using a Single-Slab, 3-Dimensional, T2-weighted Turbo-Spin-Echo Sequence With High Sampling Efficiency (SPACE) for High Spatial Resolution Imaging: Initial Clinical Experiences , 2005, Investigative radiology.

[38]  Peter R Luijten,et al.  High‐resolution magnetization‐prepared 3D‐FLAIR imaging at 7.0 Tesla , 2010, Magnetic resonance in medicine.

[39]  F A Jolesz,et al.  Fast spin-echo MR imaging of the brain and spine: current concepts. , 1992, AJR. American journal of roentgenology.

[40]  Joon-Yong Jung,et al.  SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences , 2013, European Radiology.

[41]  F A Jolesz,et al.  Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images. , 1992, Radiology.

[42]  S. Lee,et al.  Comparison of three-dimensional isotropic T1-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography of the shoulder. , 2012, Radiology.

[43]  Young Cheol Yoon,et al.  3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence , 2011, Acta radiologica.

[44]  Richard Kijowski,et al.  Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo , 2008, Magnetic resonance in medicine.

[45]  Peter R Luijten,et al.  Generalized multiple-layer appearance of the cerebral cortex with 3D FLAIR 7.0-T MR imaging. , 2012, Radiology.

[46]  Satoru Morita,et al.  Unenhanced ECG‐gated fast spin‐echo MR digital subtraction angiography (MRDSA) using short echo‐spacing three‐dimensional sequence of femoral arteries: Initial experience , 2011, Journal of magnetic resonance imaging : JMRI.

[47]  M. Viallon,et al.  High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging , 2008, European Radiology.

[48]  B. Kiefer,et al.  Three-Dimensional T 2-Weighted Imaging of the Brain Using Very Long Spin-Echo Trains , 1996 .

[49]  R. Busse,et al.  Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast , 2006, Magnetic resonance in medicine.

[50]  Patrick A Turski,et al.  Three-Dimensional Fluid Attenuated Inversion Recovery Imaging With Isotropic Resolution and Nonselective Adiabatic Inversion Provides Improved Three-Dimensional Visualization and Cerebrospinal Fluid Suppression Compared to Two-Dimensional Flair at 3 Tesla , 2008, Investigative radiology.

[51]  F Barkhof,et al.  Multicontrast Mr Imaging at 7 T in Multiple Sclerosis: Highest Lesion Detection in Cortical Gray Matter with 3d-flair 2.2 Multicontrast Mri at 7 T in Ms , 2022 .

[52]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[53]  R V Mulkern,et al.  Magnetization transfer effects in multislice RARE sequences , 1992, Magnetic resonance in medicine.

[54]  Mike P. Wattjes,et al.  Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR , 2011, European Radiology.

[55]  K. Scheffler,et al.  Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS) , 2003, Magnetic resonance in medicine.

[56]  J C Gore,et al.  The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI , 1992, Magnetic resonance in medicine.

[57]  Subha V. Raman,et al.  Initial feasibility of a multi‐station high resolution three‐dimensional dark blood angiography protocol for the assessment of peripheral arterial disease , 2009, Journal of magnetic resonance imaging : JMRI.

[58]  Michael Schär,et al.  Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 Tesla , 2011, Journal of magnetic resonance imaging : JMRI.

[59]  M Komi,et al.  Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-Weighted MR Imaging of Brain Stem Anatomy , 2012, American Journal of Neuroradiology.

[60]  Nick C Fox,et al.  The Alzheimer's disease neuroimaging initiative (ADNI): MRI methods , 2008, Journal of magnetic resonance imaging : JMRI.

[61]  F A Jolesz,et al.  T2‐weighted thin‐section imaging with the multislab three‐dimensional RARE technique , 1991, Journal of magnetic resonance imaging : JMRI.

[62]  Yiu-Cho Chung,et al.  Assessment of carotid stenosis using three‐dimensional T2‐weighted dark blood imaging: Initial experience , 2012, Journal of magnetic resonance imaging : JMRI.

[63]  D. Alsop,et al.  The sensitivity of low flip angle RARE imaging , 1997, Magnetic resonance in medicine.

[64]  P. Mukherjee,et al.  MR Imaging of Optic Neuropathy with Extended Echo-Train Acquisition Fluid-Attenuated Inversion Recovery , 2011, American Journal of Neuroradiology.

[65]  Christopher F. Beaulieu,et al.  Ankle: isotropic MR imaging with 3D-FSE-cube--initial experience in healthy volunteers. , 2008, Radiology.

[66]  Frederik Barkhof,et al.  Human gray matter: feasibility of single-slab 3D double inversion-recovery high-spatial-resolution MR imaging. , 2006, Radiology.

[67]  Debiao Li,et al.  Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study. , 2013, Radiology.

[68]  S. Herman,et al.  Partial tears of the anterior cruciate ligament: diagnostic performance of isotropic three-dimensional fast spin echo (3D-FSE-Cube) MRI , 2012, European Journal of Orthopaedic Surgery & Traumatology.

[69]  Lazar Fleysher,et al.  TROMBONE: T1‐relaxation‐oblivious mapping of transmit radio‐frequency field (B1) for MRI at high magnetic fields , 2011, Magnetic resonance in medicine.

[70]  Dong-Hyun Kim,et al.  On the use of a spin‐echo based double inversion recovery acquisition for the measurement of cortical brain thickness , 2011, Journal of magnetic resonance imaging : JMRI.

[71]  Richard Kijowski,et al.  Cartilage morphology at 3.0T: Assessment of three‐dimensional magnetic resonance imaging techniques , 2010, Journal of magnetic resonance imaging : JMRI.

[72]  Scott B Reeder,et al.  T2‐weighted 3D fast spin echo imaging with water–fat separation in a single acquisition , 2010, Journal of magnetic resonance imaging : JMRI.

[73]  F A Jolesz,et al.  Partial RF echo planar imaging with the FAISE method. I. Experimental and theoretical assessment of artifact , 1992, Magnetic resonance in medicine.

[74]  E Godehardt,et al.  Non-enhanced 3D MR angiography of the lower extremity using ECG-gated TSE imaging with non-selective refocusing pulses--initial experience. , 2010, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[75]  Michael E Moseley,et al.  Advances in magnetic resonance neuroimaging. , 2009, Neurologic clinics.

[76]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[77]  Hiroki Shirato,et al.  Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging , 2013, Journal of computer assisted tomography.

[78]  Jürgen Hennig,et al.  Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part II: Echoes in imaging sequences , 1991 .

[79]  Timothy J Carroll,et al.  Three-Dimensional T2-Weighted MRI of the Human Femoral Arterial Vessel Wall at 3.0 Tesla , 2009, Investigative radiology.

[80]  Shingo Iwano,et al.  Three‐dimensional (3D) visualization of endolymphatic hydrops after intratympanic injection of Gd‐DTPA: Optimization of a 3D‐real inversion‐recovery turbo spin‐echo (TSE) sequence and application of a 32‐channel head coil at 3T , 2010, Journal of magnetic resonance imaging : JMRI.

[81]  Henry Rusinek,et al.  Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience. , 2009, Radiology.

[82]  Eugene G Kholmovski,et al.  Correction of slab boundary artifact using histogram matching , 2002, Journal of magnetic resonance imaging : JMRI.

[83]  D. Woessner Effects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments , 1961 .

[84]  Reed F Busse,et al.  Evaluation of uterine anomalies: 3D FRFSE cube versus standard 2D FRFSE. , 2009, AJR. American journal of roentgenology.

[85]  J C Gore,et al.  Factors influencing contrast in fast spin-echo MR imaging. , 1992, Magnetic resonance imaging.

[86]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[87]  Kecheng Liu,et al.  Reduced slab boundary artifact in multi‐slab 3D fast spin‐echo imaging , 2000, Magnetic resonance in medicine.

[88]  Dominik Paul,et al.  Inner-volume 3 D Turbo-spin-echo ( SPACE ) Imaging of the Prostate : Preliminary Experience , 2011 .

[89]  K. Scheffler,et al.  Hyperechoes , 2001, Magnetic resonance in medicine.

[90]  Kaori Togashi,et al.  High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): comparison of 3T vs. 1.5T. , 2010, European journal of radiology.

[91]  Bachir Taouli,et al.  Prostate cancer: Comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection. , 2010, AJR. American journal of roentgenology.

[92]  Wilhelm Horger,et al.  MRI of the Knee at 3T: First Clinical Results With an Isotropic PDfs-Weighted 3D-TSE-Sequence , 2009, Investigative radiology.

[93]  Richard Kijowski,et al.  Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging--diagnostic performance compared with that of conventional MR imaging at 3.0 T. , 2009, Radiology.

[94]  Masatoshi Hori,et al.  Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T--initial experience. , 2011, Radiology.

[95]  Yiu-Cho Chung,et al.  T1‐weighted–SPACE dark blood whole body magnetic resonance angiography (DB‐WBMRA): Initial experience , 2010, Journal of magnetic resonance imaging : JMRI.

[96]  L Kaufman,et al.  Inner volume MR imaging: technical concepts and their application. , 1985, Radiology.

[97]  E. Hahn,et al.  Spin Echoes , 2011 .

[98]  H. Kawai,et al.  Increased sensitivity to low concentration gadolinium contrast by optimized heavily T2-weighted 3D-FLAIR to visualize endolymphatic space. , 2010, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[99]  Philip M Robson,et al.  Brain MR imaging at ultra-low radiofrequency power. , 2011, Radiology.

[100]  Eung Yeop Kim,et al.  Contrast‐enhanced, three‐dimensional, whole‐brain, black‐blood imaging: Application to small brain metastases , 2010, Magnetic resonance in medicine.

[101]  Garry E Gold,et al.  Imaging of the wrist at 1.5 tesla using isotropic three‐dimensional fast spin echo cube , 2011, Journal of magnetic resonance imaging : JMRI.

[102]  Frederik Barkhof,et al.  Improved detection of active multiple sclerosis lesions: 3D subtraction imaging. , 2010, Radiology.

[103]  Dominik Paul,et al.  3D-MRI of the Ankle With Optimized 3D-SPACE , 2012, Investigative radiology.

[104]  Pascal Chabrot,et al.  Unenhanced 3D turbo spin-echo MR angiography of lower limbs in peripheral arterial disease: a comparative study with gadolinium-enhanced MR angiography. , 2013, AJR. American journal of roentgenology.

[105]  Felix W. Wehrli,et al.  3D fast spin echo with out‐of‐slab cancellation: A technique for high‐resolution structural imaging of trabecular bone at 7 tesla , 2010, Magnetic resonance in medicine.

[106]  N. Lukzen,et al.  Analytical derivation of multiple spin echo amplitudes with arbitrary refocusing angle. , 2007, Journal of magnetic resonance.

[107]  D. Irimia,et al.  Feasibility of 3.0T pelvic MR imaging in the evaluation of endometriosis. , 2012, European journal of radiology.

[108]  Maximilian F Reiser,et al.  Assessment of the internal craniocervical ligaments with a new magnetic resonance imaging sequence: three-dimensional turbo spin echo with variable flip-angle distribution (SPACE). , 2009, Magnetic resonance imaging.

[109]  B. Kiefer,et al.  The shifted radial reordering for intermediate TE imaging in 3 D long echo train acquisition , 2008 .

[110]  Frederik Barkhof,et al.  Structural and functional hippocampal changes in multiple sclerosis patients with intact memory function. , 2010, Radiology.

[111]  Joon-Yong Jung,et al.  Meniscal tear configurations: categorization with 3D isotropic turbo spin-echo MRI compared with conventional MRI at 3 T. , 2012, AJR. American journal of roentgenology.

[112]  F A Jolesz,et al.  Optimized single-slab three-dimensional spin-echo MR imaging of the brain. , 2000, Radiology.

[113]  Keita Sakurai,et al.  Evaluation of luminal and vessel wall abnormalities in subacute and other stages of intracranial vertebrobasilar artery dissections using the volume isotropic turbo-spin-echo acquisition (VISTA) sequence: a preliminary study. , 2013, Journal of neuroradiology. Journal de neuroradiologie.

[114]  Joon-Yong Jung,et al.  Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences , 2012, Skeletal Radiology.

[115]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .