A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function

Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of +/-30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated that similar results could be reached using both methods, but large differences result for the arbitrary selection of SINV-PVC parameters. The presented SV-PVC method was performed without user intervention, requiring only a tumor mask as input. Research involving PET-imaged tumor heterogeneity should include correcting for partial volume effects to improve the quantitative accuracy of results.

[1]  S Fanti,et al.  Oncologic PET tracers beyond [(18)F]FDG and the novel quantitative approaches in PET imaging. , 2008, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[2]  Kris Thielemans,et al.  Object dependency of resolution in reconstruction algorithms with interiteration filtering applied to PET data , 2004, IEEE Transactions on Medical Imaging.

[3]  E. Veklerov,et al.  Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing , 1987, IEEE Transactions on Medical Imaging.

[4]  M. Casey,et al.  PET reconstruction with system matrix derived from point source measurements , 2004, IEEE Transactions on Nuclear Science.

[5]  S Mutic,et al.  A novel approach to overcome hypoxic tumor resistance: Cu-ATSM-guided intensity-modulated radiation therapy. , 2001, International journal of radiation oncology, biology, physics.

[6]  Joseph A. O'Sullivan,et al.  Deblurring subject to nonnegativity constraints , 1992, IEEE Trans. Signal Process..

[7]  Adam M. Alessio,et al.  Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors , 2006 .

[8]  Thomas K. Lewellen,et al.  Modeling and incorporation of system response functions in 3-D whole body PET , 2006, IEEE Transactions on Medical Imaging.

[9]  Andrew J. Reader,et al.  EM algorithm system modeling by image-space techniques for PET reconstruction , 2003 .

[10]  Kris Thielemans,et al.  Object dependency of resolution and convergence rate in OSEM with filtering , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[11]  R. Kessler,et al.  Analysis of emission tomographic scan data: limitations imposed by resolution and background. , 1984, Journal of computer assisted tomography.

[12]  F. O’Sullivan,et al.  Spatial Heterogeneity in Sarcoma 18F-FDG Uptake as a Predictor of Patient Outcome , 2008, Journal of Nuclear Medicine.

[13]  Performance comparison of two commercial BGO-based PET/CT scanners using NEMA NU 2-2001. , 2007, Medical physics.

[14]  H. Mayberg,et al.  Correction of PET Data for Partial Volume Effects in Human Cerebral Cortex by MR Imaging , 1990, Journal of computer assisted tomography.

[15]  Alan C. Evans,et al.  Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[16]  Felicia Zito,et al.  PET instrumentation and reconstruction algorithms in whole-body applications. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  M.E. Casey,et al.  A /sup 68/Ge PET hot-sphere phantom with no cold shells , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[18]  E. Levitan,et al.  A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[19]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[20]  J. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[21]  Richard M. Leahy,et al.  Resolution and noise properties of MAP reconstruction for fully 3-D PET , 2000, IEEE Transactions on Medical Imaging.

[22]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[23]  Raymond F. Muzic,et al.  A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET , 1998, IEEE Transactions on Medical Imaging.

[24]  Ralph A Bundschuh,et al.  Radioactive spheres without inactive wall for lesion simulation in PET. , 2008, Zeitschrift fur medizinische Physik.

[25]  Sutherland,et al.  Tumor Hypoxia and Heterogeneity: Challenges and Opportunities for the Future. , 1996, Seminars in radiation oncology.

[26]  Pierre Payoux,et al.  Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging. , 2005, Medical physics.

[27]  Finbarr O'Sullivan,et al.  A statistical measure of tissue heterogeneity with application to 3D PET sarcoma data. , 2003, Biostatistics.

[28]  T G Turkington,et al.  Performance characteristics of a whole-body PET scanner. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[29]  S. Libutti,et al.  Partial-Volume Correction in PET: Validation of an Iterative Postreconstruction Method with Phantom and Patient Data , 2007, Journal of Nuclear Medicine.

[30]  J. Fowler,et al.  Selective boosting of tumor subvolumes. , 2000, International journal of radiation oncology, biology, physics.

[31]  C. Byrne Iterative algorithms for deblurring and deconvolution with constraints , 1998 .

[32]  N. Volkow,et al.  Quantitation of the human basal ganglia with positron emission tomography: a phantom study of the effect of contrast and axial positioning. , 1991, IEEE transactions on medical imaging.

[33]  B. Tsui,et al.  Noise properties of the EM algorithm: II. Monte Carlo simulations. , 1994, Physics in medicine and biology.

[34]  D. Hanahan,et al.  The Hallmarks of Cancer , 2000, Cell.

[35]  C C Ling,et al.  Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality. , 2000, International journal of radiation oncology, biology, physics.

[36]  T.G. Turkington,et al.  Small spheres for lesion detection phantoms , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[37]  Thomas K. Lewellen,et al.  Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors , 2005, SPIE Medical Imaging.

[38]  Joseph O Deasy,et al.  Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods. , 2006, Medical physics.

[39]  Y. Vardi,et al.  From image deblurring to optimal investments : maximum likelihood solutions for positive linear inverse problems , 1993 .

[40]  P.E. Kinahan,et al.  Modeling and incorporation of system response functions in 3D whole body PET , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[41]  I. Buvat,et al.  Partial-Volume Effect in PET Tumor Imaging* , 2007, Journal of Nuclear Medicine.

[42]  I. Buvat,et al.  Biases affecting the measurements of tumor-to-background activity ratio in PET , 2002 .

[43]  P. Grigsby,et al.  Intratumoral Metabolic Heterogeneity of Cervical Cancer , 2008, Clinical Cancer Research.

[44]  B. Manaster Spatial Heterogeneity in Sarcoma 18F-FDG Uptake as a Predictor of Patient Outcome , 2010 .

[45]  D. Denoyer,et al.  Spectrum of radiopharmaceuticals in nuclear oncology. , 2006, Current cancer drug targets.

[46]  G. Heppner,et al.  Tumor heterogeneity: biological implications and therapeutic consequences , 2004, Cancer and Metastasis Reviews.

[47]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[48]  Donald W. Wilson,et al.  Noise properties of the EM algorithm. I. Theory , 1994 .

[49]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[50]  A. Kirov,et al.  Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology , 2008, Physics in medicine and biology.

[51]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[52]  Jinyi Qi,et al.  Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements , 2009, Physics in medicine and biology.