Determining the optimum spacing and arrangement for commercial wind towers for ventilation performance

Abstract CFD analysis of multiple wind towers located on the same building was performed following validation of a benchmark model against wind tunnel data. The positioning of the wind towers was varied in six different cases, two different arrangements with three different spacing lengths between wind towers. All analysis was compared against the benchmark (isolated) wind tower. The ability of the wind towers, particularly the leeward wind tower, to ventilate the space below was determined for a set occupancy against current guidelines for air supply rates. Furthermore, the effect of the spacing and arrangement on CO2 concentration within rooms ventilated by the leeward wind tower was investigated (re-entry of exhaust air pollutants into fresh supply). It was found that a parallel arrangement of wind towers was not effective for ventilating an occupied volume, regardless of the spacing between the two wind towers when incident wind direction was parallel to the arrangement. The maximum supply rate for the leeward wind tower in parallel arrangement at a spacing of 5 m was just over 50% of the regulation rate (10 L/s/occupant) and 40% of the supply rate of an isolated wind tower. Decreasing the spacing between the parallel wind towers to 3 m further reduces the supply rate to 2.4 L/s/occupant and the device was observed to be operating in reverse (airflow entering from leeward opening). As the angle of wind increased, an improvement of air supply rates was seen. For a staggered arrangement of wind towers, the leeward wind tower was capable of supplying the recommended ventilation rates at all tested spacing lengths. The average indoor CO2 concentration of the space with the leeward wind tower was higher in the parallel arrangement than the staggered arrangement at 0° wind angle. For the parallel arrangement, the average CO2 concentration was 28–50 ppm higher than the outdoor air. The staggered arrangement effectively minimised the re-entry of pollutants, with the indoor CO2 concentration 1–3 ppm higher than the outdoor.

[1]  Ben Richard Hughes,et al.  A numerical investigation into the effect of Windvent louvre external angle on passive stack ventilation performance , 2010 .

[2]  S. Ghani,et al.  CFD analysis of a heat transfer device integrated wind tower system for hot and dry climate , 2013 .

[3]  John Kaiser Calautit,et al.  Measurement and prediction of the indoor airflow in a room ventilated with a commercial wind tower , 2014 .

[4]  John Kaiser Calautit,et al.  Wind tunnel and CFD study of the natural ventilation performance of a commercial multi-directional wind tower , 2014 .

[5]  Jack E. Cermak,et al.  Applications of Fluid Mechanics to Wind Engineering—A Freeman Scholar Lecture , 1975 .

[6]  John D. Spengler,et al.  An experimental method for contaminant dispersal characterization in large industrial buildings for indoor air quality (IAQ) applications , 2002 .

[7]  Ben Richard Hughes,et al.  Numerical investigation of the integration of heat transfer devices into wind towers , 2013 .

[8]  Derek Clements-Croome,et al.  Ventilation rates in schools , 2008 .

[9]  John Kaiser Calautit,et al.  A numerical investigation into the feasibility of integrating green building technologies into row houses in the Middle East , 2013 .

[10]  Ben Richard Hughes,et al.  A numerical investigation into the effect of windvent dampers on operating conditions , 2009 .

[11]  Ian Ridley,et al.  Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England , 2009 .

[12]  Ray Kirby,et al.  The Performance of Natural Ventilation Windcatchers in Schools -A Comparison between Prediction and Measurement , 2010 .

[13]  H Hamid Montazeri,et al.  Experimental and numerical study on natural ventilation performance of various multi-opening wind catchers , 2011 .

[14]  John Kaiser Calautit,et al.  A study of passive ventilation integrated with heat recovery , 2014 .

[15]  N. Isyumov,et al.  Wind tunnel studies of buildings and structures , 1998 .

[16]  W. Fisk,et al.  Association of ventilation rates and CO2 concentrations with health and other responses in commercial and institutional buildings. , 1999, Indoor air.

[17]  John Kaiser Calautit,et al.  The development of commercial wind towers for natural ventilation: A review , 2012 .

[18]  Abbas Elmualim,et al.  Verification of Design Calculations of a Wind Catcher/Tower Natural Ventilation System with Performance Testing in a Real Building , 2006 .

[19]  C. Dimitroulopoulou Ventilation in European dwellings: A review , 2012 .

[20]  John Kaiser Calautit,et al.  A validated design methodology for a closed-loop subsonic wind tunnel , 2014 .

[21]  John Kaiser Calautit,et al.  Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions , 2013 .

[22]  Zhiqiang John Zhai,et al.  Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature , 2007 .

[23]  Shaun D. Fitzgerald,et al.  A comparison of winter pre-heating requirements for natural displacement and natural mixing ventilation , 2009 .

[24]  Jack E. Cermak Applications of fluid mechanics to wind engineering , 1974 .

[25]  Cheuk Ming Mak,et al.  Corrigendum to A study of wind and buoyancy driven flows through commercial wind towers [Energy & , 2011 .

[26]  Cheuk Ming Mak,et al.  Numerical evaluation of louver configuration and ventilation strategies for the windcatcher system , 2011 .

[27]  Z. Buliński,et al.  Experimentally validated CFD analysis on sampling region determination of average indoor carbon dioxide concentration in occupied space , 2014 .