Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial

PurposeThis prospective, double-blind, randomised controlled trial was designed to address the following research questions: firstly, is there a significant difference in outliers in alignment in the frontal and sagittal plane between PSG TKA and conventional TKA. Secondly, is there a significant difference in operation time, blood loss and length of hospital stay between the two techniques. We hypothesise that there will be fewer outliers with PSG TKA and that operation time, blood loss and length of hospital stay can be significantly reduced with PSG.MethodsA total of 180 patients were randomised for PSG TKA (group 1) or conventional TKA (group 2) in two centres. Patients were stratified per hospital. Alignment of the mechanical axis of the leg and flexion/extension and varus/valgus of the individual prosthesis components were measured on digital, standing, long-leg and standard lateral radiographs by two independent outcome assessors in both centres. Percentages of outliers (>3°) were determined. We compared blood loss, operation time and length of hospital stay.ResultsThere was no statistically significant difference in mean mechanical axis or outliers in mechanical axis between groups. No statistically significant difference was found for the alignment of the individual components in the frontal plane nor for the percentages of outliers. There was a statistically significant difference in outliers for the femoral component in the sagittal plane, with a higher percentage of outliers in the group 1 (p = 0.017). No such significant result was found for the tibial component in that plane. All interclass correlation coefficients were good. Blood loss was 100 mL less in group 1 (p < 0.001). Operation time was 5 min shorter in group 1 (p < 0.001). Length of hospital stay was identical with a mean of 3.6 days (p = 0.657).ConclusionsThe results in terms of obtaining a neutral mechanical axis and a correct position of the prosthesis components did not differ between groups. A small reduction in operation time and blood loss was found with the PSG system. Future research should especially focus on cost-effectiveness analysis and functional outcome of PSG TKA.Level of evidenceI.

[1]  Sébastien Lustig,et al.  Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. , 2013, The Journal of arthroplasty.

[2]  R. Barrack,et al.  Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[3]  C. Pornrattanamaneewong,et al.  A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. , 2013, The bone & joint journal.

[4]  Ning Liu,et al.  The value of patient-matched instrumentation in total knee arthroplasty. , 2012, The Journal of arthroplasty.

[5]  K. Daniilidis,et al.  Frontal plane alignment after total knee arthroplasty using patient-specific instruments , 2012, International Orthopaedics.

[6]  Andrew D Pearle,et al.  Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. , 2013, The Knee.

[7]  Andrea Ferretti,et al.  Evaluation of the accuracy of a patient-specific instrumentation by navigation , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[8]  Michael A. Mont,et al.  Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment , 2009, International Orthopaedics.

[9]  Robert L. Barrack,et al.  Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[10]  T. Fehring,et al.  Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. , 2007, The Journal of arthroplasty.

[11]  H. Picavet,et al.  [Trends in the number of knee and hip arthroplasties: considerably more knee and hip prostheses due to osteoarthritis in 2030]. , 2010, Nederlands tijdschrift voor geneeskunde.

[12]  B. Boonen,et al.  Preliminary experience with the patient-specific templating total knee arthroplasty , 2012, Acta orthopaedica.

[13]  S. Kurtz,et al.  International survey of primary and revision total knee replacement , 2011, International Orthopaedics.

[14]  J. Moreland,et al.  Radiographic analysis of the axial alignment of the lower extremity. , 1987, The Journal of bone and joint surgery. American volume.

[15]  A. Lombardi,et al.  Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA , 2012, Clinical orthopaedics and related research.