Mechanical strength and fracture point of a dental implant under certification conditions: A numerical approach by finite element analysis

Statement of problem: Implant prosthodontics provides high‐quality outcomes thanks to recent technological developments and certification procedures such as International Organization for Standardization (ISO) 14801. However, these certification tests are costly, and the result is highly uncertain as the influence of design variables (materials and structure) is still unknown. The design process could be significantly improved if the influence of design parameters were identified. Purpose: The purpose of this in vitro study was to use finite element analysis (FEA) to assess the influence of design parameters on the mechanical performance of an implant in regard to testing conditions of ISO 14801 standard. Material and methods: An endosseous dental implant was loaded under ISO 14801 testing conditions by numerical simulation, with 4 parameters evaluated under the following conditions: conditions of the contact surface area between the implant and the loading tool, length of the fixation screw, implant embedding depth, and material used for implant stiffness. FEA was used to compare the force that needed to reach the implant's yield and fracture strength. Results: A dental implant's fracture point can be increased by 41% by improving the contact surface area, by 20% depending on the type of material, by 4% depending on the length of the fixation screw, and by 1.4% by changing the implant embedding depth. Conclusions: FEA made it possible to evaluate 4 performance parameters of a dental implant under ISO 14801 conditions. Under these conditions, the contact surface area was found to be the major parameter influencing implant performance. This observation was validated experimentally in a fatigue test under ISO 14801 conditions.

[1]  C. Murray,et al.  A review of dental implants and infection. , 2009, The Journal of hospital infection.

[2]  C J Goodacre,et al.  Clinical complications of osseointegrated implants. , 1999, The Journal of prosthetic dentistry.

[3]  Marco Migliorati,et al.  Miniscrew design and bone characteristics: an experimental study of primary stability. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[4]  A. Nicolini,et al.  Osteoporosis and biomaterial osteointegration. , 2004, Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie.

[5]  K. Ikebe,et al.  Association of bite force with ageing and occlusal support in older adults. , 2005, Journal of dentistry.

[6]  Jan Wolff,et al.  Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone - a feasibility study. , 2014, Journal of biomechanics.

[7]  V. Ilankovan Anatomy of ageing face. , 2014, The British journal of oral & maxillofacial surgery.

[8]  T. van Eijden,et al.  Contribution of Jaw Muscle Size and Craniofacial Morphology to Human Bite Force Magnitude , 1999, Journal of dental research.

[9]  J. Brunski Biomaterials and biomechanics in dental implant design. , 1988, The International journal of oral & maxillofacial implants.

[10]  K S Hebel,et al.  Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. , 1997, The Journal of prosthetic dentistry.

[11]  J. Montiel-Company,et al.  Factors associated with edentulousness in an elderly population in Valencia (Spain). , 2013, Gaceta sanitaria.

[12]  Georges Limbert,et al.  Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study. , 2010, Journal of biomechanics.

[13]  Gregory Dolin,et al.  8U.S. Food and Drug Administration , 2016 .

[14]  Ja Hobkirk,et al.  Expert Commentary on ISO 14801:2016, Dentistry - Implants Dynamic loading test for endosseous dental implants , 2016 .

[15]  Liang Kong,et al.  Optimum selection of the dental implant diameter and length in the posterior mandible with poor bone quality – A 3D finite element analysis , 2011 .

[16]  G. Throckmorton,et al.  Effect of an auditory cue on chewing cycle kinematics. , 2006, Archives of oral biology.

[17]  Fatigue life estimation in dental implants , 2014 .

[18]  Stephen P. Timoshenko,et al.  History of strength of materials : with a brief account of the history of theory of elasticity and theory of structures , 1983 .

[19]  H. Hayasaki,et al.  Quantification of human chewing-cycle kinematics. , 2000, Archives of oral biology.

[20]  J. Davies,et al.  The roles of different scale ranges of surface implant topography on the stability of the bone/implant interface. , 2013, Biomaterials.

[21]  F. Hölzle,et al.  Stability of edentulous, atrophic mandibles after insertion of different dental implants. A biomechanical study. , 2015, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[22]  C. Elias,et al.  Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants. , 2015, Dental materials : official publication of the Academy of Dental Materials.

[23]  Sanjib Kumar Acharyya,et al.  Determination of Johnson cook material and failure model constants and numerical modelling of Charpy impact test of armour steel , 2015 .

[24]  K. Littlewood High fidelity simulation as a research tool. , 2011, Best practice & research. Clinical anaesthesiology.

[25]  J. Vleugels,et al.  Titanium implants with modified surfaces: meta-analysis of in vivo osteointegration. , 2015, Materials science & engineering. C, Materials for biological applications.

[26]  Abhay Kumar Jain,et al.  Bone density and its importance in orthodontics. , 2013, Journal of oral biology and craniofacial research.

[27]  J. Keith Nisbett,et al.  Shigley's Mechanical Engineering Design , 1983 .

[28]  Shuichi Nomura,et al.  Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: a three-dimensional finite element analysis. , 2010, Journal of prosthodontic research.

[29]  F. Dametto,et al.  COMPRESSIVE FATIGUE IN TITANIUM DENTAL IMPLANTS SUBMITTED TO FLUORIDE IONS ACTION , 2007, Journal of applied oral science : revista FOB.

[30]  Fehmi Erzincanlı,et al.  Static, dynamic and fatigue behaviors of dental implant using finite element method , 2006, Adv. Eng. Softw..

[31]  M. Özcan,et al.  Fracture strength of implant abutments after fatigue testing: A systematic review and a meta-analysis. , 2016, Journal of the mechanical behavior of biomedical materials.

[32]  David Kennedy,et al.  Design of dynamic test equipment for the testing of dental implants , 2005 .

[33]  V Moraschini,et al.  Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review. , 2015, International journal of oral and maxillofacial surgery.

[34]  U. Lekholm Clinical procedures for treatment with osseointegrated dental implants. , 1983, The Journal of prosthetic dentistry.

[35]  T. Kuboki,et al.  The effect of growth factors for bone augmentation to enable dental implant placement: A systematic review , 2010 .

[36]  Qing Li,et al.  Mandibular bone remodeling induced by dental implant. , 2010, Journal of biomechanics.

[37]  Radovan Kovacevic,et al.  Fatigue properties of a dental implant produced by electron beam melting® (EBM) , 2015 .

[38]  Wei Li,et al.  Evaluation of Dental Implant Induced Bone Remodelling by Using a 2D Finite Element Model , 2007 .

[39]  M. A. Pérez,et al.  Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions , 2012, Comput. Methods Programs Biomed..