The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

BACKGROUND UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. AIMS The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. METHODS The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is completed on whole blood from all participants, since such assays need to be conducted on fresh samples (whereas other assays can be done on stored samples). By the end of the recruitment phase, 15 million sample aliquots will be stored in two geographically separate archives: 9.5 million in a -80 degrees C automated archive and 5.5 million in a manual liquid nitrogen archive at -180 degrees C. Because of the size of the study and the numbers of samples obtained from participants, the protocol stipulates a highly automated approach for the processing and storage of samples. Implementation of the processes, technology, systems and facilities has followed best practices used in manufacturing industry to reduce project risk and to build in quality and robustness. The data produced from sample collection, processing and storage are highly complex and are managed by a commercially available LIMS system fully integrated with the entire process. CONCLUSION The sample handling and storage protocol adopted by UK Biobank provides quality assured and validated methods that are feasible within the available funding and reflect the size and aims of the project. Experience from recruiting and processing the first 40,000 participants to the study demonstrates that the adopted methods and technologies are fit-for-purpose and robust.

[1]  C. Coburn,et al.  Effect of sodium ascorbate concentration on the stability of samples for determination of serum folate levels. , 1977, American journal of clinical pathology.

[2]  J. M. Harrington,et al.  A survey of a population exposed to high concentrations of arsenic in well water in Fairbanks, Alaska. , 1978, American journal of epidemiology.

[3]  E. Marafante,et al.  Metabolism of arsenobetaine in mice, rats and rabbits. , 1983, The Science of the total environment.

[4]  S. Joel,et al.  Measuring cytokine levels in blood. Importance of anticoagulants, processing, and storage conditions. , 1992, Journal of immunological methods.

[5]  P. Reilly DNA banking. , 1992, American journal of human genetics.

[6]  K. Syndulko,et al.  Human neuro-specimen banking 1961-1992. The National Neurological Research Specimen Bank (a donor program of pre- and post-mortem tissues and cerebrospinal fluid/blood; and a collection of cryopreserved human neurological specimens for neuroscientists). , 1993, Journal of neural transmission. Supplementum.

[7]  R. Canfield,et al.  The development of assays for the detection of fibrin(ogen)olysis based on COOH-terminal A alpha chain epitopes. , 1994, Blood.

[8]  Ethical considerations in the design and execution of the National and Hispanic Health and Nutrition Examination Survey (HANES). , 1995, Environmental health perspectives.

[9]  M. Firestone,et al.  Coupling transport and biodegradation of VOCs in surface and subsurface soils. , 1995, Environmental health perspectives.

[10]  E Riboli,et al.  The EPIC Project: rationale and study design. European Prospective Investigation into Cancer and Nutrition. , 1997, International journal of epidemiology.

[11]  B. P. Eynon,et al.  'Spontaneous' genetic damage in man: evaluation of interindividual variability, relationship among markers of damage, and influence of nutritional status. , 1997, Mutation research.

[12]  K. Nuttall,et al.  Effect of storage on serum vitamin B12 and folate stability. , 1997, Annals of clinical and laboratory science.

[13]  M T Landi,et al.  Sample collection, processing and storage. , 1997, IARC scientific publications.

[14]  Elio Riboli,et al.  The EPIC Project: Rationale and study design , 1997 .

[15]  E W Gunter,et al.  Biological and environmental specimen banking at the Centers for Disease Control and Prevention. , 1997, Chemosphere.

[16]  Kinetic and Stereoselective Characterisation of Lamb Pregastric Lipase Catalysed Reactions , 1997 .

[17]  G. Berglund,et al.  Quality control program for storage of biologically banked blood specimens in the Malmö Diet and Cancer Study. , 1998, Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology.

[18]  L. Le Marchand,et al.  A simple mouthwash method for obtaining genomic DNA in molecular epidemiological studies. , 1998, Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology.

[19]  Peripheral specimen collecting centers. Preanalytical control , 1998 .

[20]  [Peripheral specimen collecting centers. Preanalytical control]. , 1998, Revista de enfermeria.

[21]  R. Detels,et al.  Variables That Affect Assays for Plasma Cytokines and Soluble Activation Markers , 1999, Clinical Diagnostic Laboratory Immunology.

[22]  B. No̸rgaard-Pedersen,et al.  Biological specimen banks in neonatal screening , 1999, Acta paediatrica (Oslo, Norway : 1992). Supplement.

[23]  M. Lederman,et al.  Stability of plasma levels of cytokines and soluble activation markers in patients with human immunodeficiency virus infection. , 1999, The Journal of infectious diseases.

[24]  R. Hayes,et al.  Self-collection of oral epithelial cell DNA under instruction from epidemiologic interviewers. , 2000, American journal of epidemiology.

[25]  P. Mendola,et al.  Evaluation of a container for collection and shipment of semen with potential uses in population-based, clinical, and occupational settings. , 2000, Journal of andrology.

[26]  H. Schünemann,et al.  Short-term storage of blood samples and DNA isolation in serum separator tubes for application in epidemiological studies and clinical research. , 2000, Annals of epidemiology.

[27]  M. Fenech,et al.  3.12 – Folate, Vitamin B12, Homocysteine Status and DNA Damage in Young Australian Adults , 2000 .

[28]  M Rossbach,et al.  Representative sampling and sample preparation in biological environmental monitoring using spruce shoots. , 2001, Journal of environmental monitoring : JEM.

[29]  R. Tracy,et al.  Longitudinal Stability of Coagulation, Fibrinolysis, and Inflammation Factors in Stored Plasma Samples , 2001, Thrombosis and Haemostasis.

[30]  R. House Cytokine measurement techniques for assessing hypersensitivity. , 2001, Toxicology.

[31]  D. Grobbee,et al.  Quality and quantity of DNA isolated from frozen urine in population-based research. , 2002, Analytical biochemistry.

[32]  B. Mendonca,et al.  Effects of EDTA and Sodium Citrate on hormone measurements by fluorometric (FIA) and immunofluorometric (IFMA) methods , 2002, BMC clinical pathology.

[33]  S. Jewell,et al.  Analysis of the molecular quality of human tissues: an experience from the Cooperative Human Tissue Network. , 2002, American journal of clinical pathology.

[34]  Eric Sampson,et al.  DNA Banking for Epidemiologic Studies: A Review of Current Practices , 2002, Epidemiology.

[35]  Brenda Eskenazi,et al.  Biological sample collection and processing for molecular epidemiological studies. , 2003, Mutation research.

[36]  M L Simoons,et al.  Logistics and quality control for DNA sampling in large multicenter studies , 2003, Journal of thrombosis and haemostasis : JTH.

[37]  Paola Muti [Biological specimen banks: epidemiological tools and scientific enterprises]. , 2003, Epidemiologia e prevenzione.

[38]  H Kesteloot,et al.  INTERMAP: background, aims, design, methods, and descriptive statistics (nondietary) , 2003, Journal of Human Hypertension.

[39]  S. Bonassi,et al.  Pooled analysis of epidemiological studies involving biological markers. , 2003, International journal of hygiene and environmental health.

[40]  I. Wilson,et al.  Gut microorganisms, mammalian metabolism and personalized health care , 2005, Nature Reviews Microbiology.

[41]  Evaluation of mercury in hair, blood and muscle as biomarkers for methylmercury exposure in male and female mice , 2007, Archives of Toxicology.

[42]  N. Thelwell,et al.  The quality of DNA extracted from liquid or dried blood is not adversely affected by storage at 4 degrees C for up to 24 h. , 2008, International journal of epidemiology.

[43]  Design and implementation of a large-scale liquid nitrogen archive. , 2008, International journal of epidemiology.

[44]  S. D. Sales,et al.  Designing an automated blood fractionation system. , 2008, International journal of epidemiology.

[45]  Paul Elliott,et al.  The UK Biobank sample handling and storage validation studies. , 2008, International journal of epidemiology.

[46]  Designing and implementing a large-scale automated -80 degrees C archive. , 2008, International journal of epidemiology.