Lighting quality recommendations for VDT offices: a new method of derivation

An experiment in a mock-up office space gave occupants control over dimmable lighting circuits after a day working under pseudo-random lighting conditions. Data analysis indicated that the lighting experienced during the day influenced the changes in lighting made at the end of the day. Occupants chose to reduce screen glare if any existed. Even after allowing for the effect of glare, desktop illuminance at day’s end varied with the illuminance experienced during the day. Regression of these end-of-day choices relative to the illuminance experienced during the day can yield a preferred illuminance, equivalent to the daytime illuminance at which no change was preferred at day’s end. Using this method, preferred illuminances in the range 200-500 lux were derived. Preferences for luminance ratio were also derived. Interestingly, the deviation between participants’ lighting preferences and the lighting they experienced during the day was a significant predictor of participant mood and satisfaction.

[1]  Evan Mills,et al.  Trends in Recommended Illuminance Levels: An International Comparison , 1999 .

[2]  Peter Boyce,et al.  Illuminance Selection Based on Visual Performance—and other Fairy Stories , 1996 .

[3]  P. Lachenbruch Statistical Power Analysis for the Behavioral Sciences (2nd ed.) , 1989 .

[4]  R. Baron,et al.  Effects of indoor lighting (illuminance and spectral distribution) on the performance of cognitive tasks and interpersonal behaviors: The potential mediating role of positive affect , 1992 .

[5]  Robert A. Baron,et al.  A Whiff of Reality , 1994 .

[6]  Kevin W. Houser,et al.  Toward the Accuracy of Lighting Simulations in Physically Based Computer Graphics Software , 1999 .

[7]  L. Loe,et al.  Appearance of lit environment and its relevance in lighting design: Experimental study , 1994 .

[8]  Jennifer A. Veitch,et al.  Preferred luminous conditions in open-plan offices: research and practice recommendations , 2000 .

[9]  Jennifer A. Veitch,et al.  Determinants of Lighting Quality II: Research and Recommendations. , 1996 .

[10]  Guy R. Newsham,et al.  Lighting quality and energy-efficiency effects on task performance , 1998 .

[11]  Fred Bauman,et al.  A field study of thermal environments and comfort in office buildings , 1988 .

[12]  Jennifer A. Veitch,et al.  EXERCISED CONTROL, LIGHTING CHOICES, AND ENERGY USE: AN OFFICE SIMULATION EXPERIMENT , 2000 .

[13]  Jennifer A. Veitch,et al.  Determinants of Lighting Quality I: State of the Science , 1998 .