EXPERIMENTAL LEAD ZIRCONATE TITANATE (PZT) SLIP SENSOR
暂无分享,去创建一个
Future advanced artificial hands will require the automatic holding of objects using feedback control. To achieve this aim will require sensors of various types, one of which should be capable of detecting the relative movement between the surface of a grasped object and the hand (slip). A low-cost sensor, using thick-film technology, has been developed which detects slip using the piezoelectric effect. Experimental evaluation of the sensor has been carried out using a test apparatus whereby a block of aluminium representing an object slides past the sensor. Attached to the object surface is a Perspex sheet with repeating groves cut into the surface. Two different separations of the groves have been tested. The results show that the slip sensor detects the relative velocity between a moving object and the sensor surface. The sensor has a frequency response into the kilohertz which makes it an excellent candidate for a slip sensor. The sensor is able to detect slip with and without a cosmetic material covering the sensor. Computer simulations of the mechanical modes of vibration have shown that the frequency of the lowest fundamental mode is much higher than the electronic signal output from the sensor.
[1] Neil M. White,et al. Control Strategies for a Multiple Degree of Freedom Prosthetic Hand , 2006 .
[2] P. Chappell,et al. Thick-film force, slip and temperature sensors for a prosthetic hand , 2005 .
[3] N.M. White,et al. A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand , 2007, IEEE Sensors Journal.
[4] Neil M. White,et al. Slip sensors for a prosthetic hand , 2007 .