The need for temperature zoning in high-performance residential buildings

The development from poorly insulated and leaky buildings to modern high-performance buildings, such as passive houses, has led to considerable improvements regarding thermal comfort. However, user evaluations of passive houses that solely employ air heating indicate that bathrooms are often perceived as too cold and bedrooms as too warm. Based on these experiences, the functional requirement of providing thermal comfort using only air heating has not been adopted in the Norwegian standard for passive houses. Instead, usually local heat sources are installed in living rooms and bathrooms to facilitate temperature zoning within the dwelling. The questions asked in this study are how well this heating and ventilation concept functions in practice from the occupants’ point of view and whether it provides thermal comfort in the various rooms. Therefore, a questionnaire was distributed to the occupants of a typical multifamily passive house project in Norway. Despite the small sample size, the findings give important insight into the residents’ perception of the thermal conditions and clearly demonstrate the limitations of the heating and ventilation solution. Based on the results, the need for further development and further studies to provide temperature zoning is outlined.

[1]  Åshild Lappegard Hauge,et al.  User evaluations of energy efficient buildings: Literature review and further research , 2011 .

[2]  N. A. Oseland,et al.  A comparison of the predicted and reported thermal sensation vote in homes during winter and summer , 1994 .

[3]  Jan Hensen,et al.  Thermal comfort in residential buildings: Comfort values and scales for building energy simulation , 2009 .

[4]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[5]  Christian Cox FINAL REPORT CONTRACT Nº: ENK6-CT-2001-00505 ACRONYM: HOPE TITLE: Health Optimisation Protocol for Energy-efficient Buildings Pre-normative and socio-economic research to create healthy and energy- efficient buildings , 2005 .

[6]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[7]  James D. Wright,et al.  Handbook of Survey Research. , 1985 .

[8]  Hua Ge,et al.  Sleep thermal comfort and the energy saving potential due to reduced indoor operative temperature during sleep , 2013 .

[9]  Hans Martin Post-Occupancy Evaluation of Low-Energy and Passive House Apartments in the Løvåshagen Cooperative — Occupant Behavior and Satisfaction , 2013 .

[10]  Petra Lietz,et al.  Research into Questionnaire Design: A Summary of the Literature , 2010 .

[11]  Pawel Wargocki,et al.  Window-opening behaviour when classroom temperature and air quality are manipulated experimentally (ASHRAE 1257-RP) , 2008 .

[12]  Lejla Selimovic Energy analysis and experience obtained from the first passive house area in Norway , 2014 .

[13]  Andreas H. Hermelink,et al.  CEPHEUS results : measurements and occupants' satisfaction provide evidence for Passive Houses being an option for sustainable building , 2006 .

[14]  Fredrik Karlsson,et al.  Indoor climate in low-energy houses : an interdisciplinary investigation , 2006 .

[15]  V. Candas,et al.  Ambient temperature and human sleep , 1984, Experientia.

[16]  Craig Brown,et al.  Understanding the role of inhabitants in innovative mechanical ventilation strategies , 2015 .