Millimeter-wave sensor based on a λ/2-line resonator for identification and dielectric characterization of non-ionic surfactants

Studies of biological and artificial membrane systems, such as niosomes, currently rely on the use of fluorescent tags, which can influence the system under investigation. For this reason, the development of label-free, non-invasive detection techniques is of great interest. We demonstrate an open-volume label-free millimeter-wave sensing platform based on a coplanar waveguide, developed for identification and characterization of niosome constituents. A design based on a λ/2-line resonator was used and on-wafer measurements of transmission and reflection parameters were performed up to 110 GHz. Our sensor was able to clearly distinguish between common niosome constituents, non-ionic surfactants Tween 20 and Span 80, measuring a resonance shift of 3 GHz between them. The complex permittivities of the molecular compounds have been extracted. Our results indicate insignificant frequency dependence in the investigated frequency range (3 GHz – 110 GHz). Values of permittivity around 3.0 + 0.7i and 2.2 + 0.4i were obtained for Tween 20 and Span 80, respectively.

[1]  R. Cole,et al.  Dielectric Relaxation in Glycerol, Propylene Glycol, and n‐Propanol , 1951 .

[2]  W. Gorman,et al.  Use of dielectric constants in the classification of surfactants. , 1963, Journal of pharmaceutical sciences.

[3]  C. Wen Coplanar Waveguide, a Surface Strip Transmission Line Suitable for Nonreciprocal Gyromagnetic Device Applications , 1969 .

[4]  G. F. Engen,et al.  Thru-Reflect-Line: An Improved Technique for Calibrating the Dual Six-Port Automatic Network Analyzer , 1979 .

[5]  S. Chou,et al.  Characteristics of coplanar transmission lines on multilayer substrates: modeling and experiments , 1997 .

[6]  P. Lunkenheimer,et al.  Dielectric and far-infrared spectroscopy of glycerol , 1998 .

[7]  Lydia L. Sohn,et al.  Dielectric spectroscopy for bioanalysis: From 40 Hz to 26.5 GHz in a microfabricated wave guide , 2001 .

[8]  A. Schätzlein,et al.  Glucose-targeted niosomes deliver vasoactive intestinal peptide (VIP) to the brain. , 2004, International journal of pharmaceutics.

[9]  Friedrich C. Simmel,et al.  Detection of lipid bilayer and peptide pore formation at gigahertz frequencies , 2006 .

[10]  Tsong-Long Hwang,et al.  Liposomes as Vehicles for Enhancing Drug Delivery Via Skin Routes , 2006 .

[11]  Makoto Takahashi,et al.  Evaluation of an oral carrier system in rats: bioavailability and antioxidant properties of liposome-encapsulated curcumin. , 2009, Journal of agricultural and food chemistry.

[12]  T. Fujii,et al.  Integrated Broadband Microwave and Microfluidic Sensor Dedicated to Bioengineering , 2009, IEEE Transactions on Microwave Theory and Techniques.

[13]  Yan Ma,et al.  Stabilized liposomal nanohybrid cerasomes for drug delivery applications. , 2010, Chemical communications.

[14]  Michael D. Janezic,et al.  Quantitative Permittivity Measurements of Nanoliter Liquid Volumes in Microfluidic Channels to 40 GHz , 2010, IEEE Transactions on Instrumentation and Measurement.

[15]  S. Chaudhari,et al.  Niosomes: novel sustained release nonionic stable vesicular systems--an overview. , 2012, Advances in colloid and interface science.

[16]  David Dubuc,et al.  Recent Advances in Microwave-Based Dielectric Spectroscopy at the Cellular Level for Cancer Investigations , 2013, IEEE Transactions on Microwave Theory and Techniques.

[17]  Michel Soustelle,et al.  Modeling and Experiments , 2013 .

[18]  H. Zirath,et al.  Suppression of Parasitic Substrate Modes in Multilayer Integrated Circuits , 2015, IEEE Transactions on Electromagnetic Compatibility.

[19]  Bart Nauwelaers,et al.  Sensitivity Analysis of Broadband On-Wafer Dielectric Spectroscopy of Yeast Cell Suspensions up to 110 GHz , 2015, IEEE Microwave and Wireless Components Letters.