Power quality improvement with an extended custom power park

This paper describes the operation principles of an extended custom power park (CPP). The proposed park is more effective when it is compared to the conventional power parks regarding the yield of improving both current and voltage quality of linear and nonlinear loads using dynamic voltage restorer (DVR), active power filter (APF), static transfer switch (STS) and diesel generator (DG). Moreover, a supervisory power quality control centre is presented to coordinate these custom power (CP) devices by providing pre-specified quality of power. A fast sag/swell detection unit is also presented to improve the system response. The ability of the extended CPP for power quality improvements is further analyzed using PSCAD/EMTDC through a set of simulation tests.

[1]  A. Domijan,et al.  An investigation toward new technologies and issues in power quality , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[2]  Po-Tai Cheng,et al.  Design and implementation of a series voltage sag compensator under practical utility conditions , 2003 .

[3]  Arindam Ghosh Performance study of two different compensating devices in a custom power park , 2005 .

[4]  Rae-Young Kim,et al.  A study on DVR control for unbalanced voltage compensation , 2001, APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335).

[5]  P. Salmeron,et al.  Instantaneous Reactive Power Theory: A Comparative Evaluation of Different Formulations , 2007, IEEE Transactions on Power Delivery.

[6]  F. Blaabjerg,et al.  A novel control algorithm for static series compensators by use of PQR instantaneous power theory , 2004, IEEE Transactions on Power Electronics.

[7]  A. Sannino,et al.  A summary of the draft IEEE P1409 custom power application guide , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[8]  Teodiano Bastos,et al.  SLAM-based robotic wheelchair navigation system designed for confined spaces , 2010, 2010 IEEE International Symposium on Industrial Electronics.

[9]  M. Barnes,et al.  Voltage sag detection technique for a dynamic voltage restorer , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[10]  A. Ghosh,et al.  The concept and operating principles of a mini custom power park , 2004, IEEE Transactions on Power Delivery.

[11]  M. Aredes,et al.  A DQ Synchronous Reference Frame Current Control for Single-Phase Converters , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[12]  A. Domijan,et al.  Simulation study of the world's first distributed premium power quality park , 2005, IEEE Transactions on Power Delivery.

[13]  P. Pillay,et al.  A New Method of Voltage Sag and Swell Detection , 2007, IEEE Transactions on Power Delivery.

[14]  M.H.J. Bollen,et al.  Power electronics for power quality improvements , 2003, 2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692).

[15]  E. Acha,et al.  Modeling and Analysis of Custom Power Systems by PSCAD/EMTDC , 2001, IEEE Power Engineering Review.

[16]  A. Sannino Static transfer switch: analysis of switching conditions and actual transfer time , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[17]  H Markiewicz,et al.  Voltage Disturbances Standard EN 50160 - Voltage Characteristics in Public Distribution Systems , 2008 .

[18]  Y.S. Jeon,et al.  Development of Validation Testing Technology for the Custom Power Device in Korea , 2005, 2005 International Conference on Electrical Machines and Systems.

[19]  Y.H. Chung,et al.  Voltage sag, swell and flicker generator with series injected inverter , 2005, IEEE Power Engineering Society General Meeting, 2005.