A novel computational method to determine subject-specific bite force and occlusal loading during mastication

Abstract The evaluation of three-dimensional occlusal loading during biting and chewing may assist in development of new dental materials, in designing effective and long-lasting restorations such as crowns and bridges, and for evaluating functional performance of prosthodontic components such as dental and/or maxillofacial implants. At present, little is known about the dynamic force and pressure distributions at the occlusal surface during mastication, as these quantities cannot be measured directly. The aim of this study was to evaluate subject-specific occlusal loading forces during mastication using accurate jaw motion measurements. Motion data was obtained from experiments in which an individual performed maximal effort dynamic chewing cycles on a rubber sample with known mechanical properties. A finite element model simulation of one recorded chewing cycle was then performed to evaluate the deformation of the rubber. This was achieved by imposing the measured jaw motions on a three-dimensional geometric surface model of the subject’s dental impressions. Based on the rubber’s deformation and its material behaviour, the simulation was used to compute the resulting stresses within the rubber as well as the contact pressures and forces on the occlusal surfaces. An advantage of this novel modelling approach is that dynamic occlusal pressure maps and biting forces may be predicted with high accuracy and resolution at each time step throughout the chewing cycle. Depending on the motion capture technique and the speed of simulation, the methodology may be automated in such a way that it can be performed chair-side. The present study demonstrates a novel modelling methodology for evaluating dynamic occlusal loading during biting or chewing.

[1]  M. Çehreli,et al.  The influence of functional forces on the biomechanics of implant-supported prostheses--a review. , 2002, Journal of dentistry.

[2]  Anders Bergmark,et al.  A novel sensor for bite force determinations. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[3]  Michael V Swain,et al.  State of the Art of Micro-CT Applications in Dental Research , 2009, International Journal of Oral Science.

[4]  I. Grosse,et al.  Using occlusal wear information and finite element analysis to investigate stress distributions in human molars , 2011, Journal of anatomy.

[5]  C. Engh,et al.  Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. , 1992, Clinical orthopaedics and related research.

[6]  W. Hnat,et al.  A study of maximum bite force during growth and development. , 2010, The Angle orthodontist.

[7]  G. Liu,et al.  Application of finite element analysis in implant dentistry: a review of the literature. , 2001, The Journal of prosthetic dentistry.

[8]  Joanita M. Kant,et al.  Why Don't More American Indians Become Engineers in South Dakota? , 2015, Int. J. Eng. Soc. Justice Peace.

[9]  O. Röhrle,et al.  Occlusal loading during biting from an experimental and simulation point of view. , 2018, Dental materials : official publication of the Academy of Dental Materials.

[10]  T. Nokubi,et al.  Association between masticatory performance and maximal occlusal force in young men. , 2003, Journal of oral rehabilitation.

[11]  T. van Eijden,et al.  Contribution of Jaw Muscle Size and Craniofacial Morphology to Human Bite Force Magnitude , 1999, Journal of dental research.

[12]  D. Steenberghe,et al.  The development of a maximal clenching force between two antagonistic teeth. , 1978 .

[13]  R M Pilliar,et al.  Dental implant design--effect on bone remodeling. , 1991, Journal of biomedical materials research.

[14]  W. Hnat,et al.  A study of bite force, part 2: Relationship to various cephalometric measurements. , 1995, The Angle orthodontist.

[15]  J. S. Wang,et al.  The effects of dental condition on hand strength and maximum bite force. , 1993, Cranio : the journal of craniomandibular practice.

[16]  M. Bakke,et al.  Effects of ethnicity, gender and age on clenching force and load distribution , 2001, Clinical Oral Investigations.

[17]  Jaroslav Mackerle,et al.  Finite Element Modelling and Simulations in Dentistry: A Bibliography 1990–2003 , 2004, Computer methods in biomechanics and biomedical engineering.

[18]  O Hidaka,et al.  Influence of Clenching Intensity on Bite Force Balance, Occlusal Contact Area, and Average Bite Pressure , 1999, Journal of dental research.

[19]  Sharath Umesh,et al.  Fiber Bragg Grating based bite force measurement. , 2016, Journal of biomechanics.

[20]  J. P. Lund,et al.  Influence of age on adaptability of human mastication. , 2004, Journal of Neurophysiology.

[21]  Oliver Röhrle,et al.  Using a motion-capture system to record dynamic articulation for application in CAD/CAM software. , 2009, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[22]  Mladen Slaj,et al.  Maximum voluntary molar bite force in subjects with normal occlusion. , 2011, European journal of orthodontics.

[23]  A. Mugan,et al.  Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis. , 2015, Journal of biomechanics.

[24]  A. van der Bilt,et al.  Biting and Chewing in Overdentures, Full Dentures, and Natural Dentitions , 2000, Journal of dental research.

[25]  Chiarella Sforza,et al.  Maximal bite forces in healthy young adults as predicted by surface electromyography. , 2004, Journal of dentistry.

[26]  William Irvin Sellers,et al.  Using sensitivity analysis to validate the predictions of a biomechanical model of bite forces. , 2004, Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft.

[27]  A. Pullan,et al.  Three-dimensional finite element modelling of muscle forces during mastication. , 2007, Journal of biomechanics.

[28]  T. Chow,et al.  Strain analysis of maxillary complete denture with three-dimensional finite element method. , 2010, The Journal of prosthetic dentistry.

[29]  E. Lynch,et al.  Maximum bite force following unilateral implant-supported prosthetic treatment: within-subject comparison to opposite dentate side. , 2014, Journal of oral rehabilitation.

[30]  A Yamashita,et al.  Comparison of biting forces in different age and sex groups: a study of biting efficiency with mobile and non-mobile teeth. , 1999, Journal of oral rehabilitation.

[31]  W. Proffit,et al.  Occlusal Forces in Normal- and Long-face Adults , 1983, Journal of dental research.

[32]  Y. Hattori,et al.  Bite forces and their resultants during forceful intercuspal clenching in humans. , 2009, Journal of biomechanics.

[33]  Oliver Röhrle,et al.  Automatically Generating Subject-specific Functional Tooth Surfaces Using Virtual Mastication , 2009, Annals of Biomedical Engineering.

[34]  D. van Steenberghe,et al.  The development of a maximal clenching force between two antagonistic teeth. , 1978, Journal of periodontal research.

[35]  Albert J Feilzer,et al.  The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[36]  M. Bakke,et al.  Bite Force and Occlusion , 2006 .

[37]  J. Bobyn,et al.  Producing and Avoiding Stress Shielding , 2006 .