Image reconstruction for interrupted-beam x-ray CT on diagnostic clinical scanners

Low-dose X-ray CT is a major research area with high clinical impact. Compressed sensing using view-based sparse sampling and sparsity-promoting regularization has shown promise in simulations, but these methods can be difficult to implement on diagnostic clinical CT scanners since the X-ray beam cannot be switched on and off rapidly enough. An alternative to view-based sparse sampling is interrupted-beam sparse sampling. SparseCT is a recently-proposed interrupted-beam scheme that achieves sparse sampling by blocking a portion of the beam using a multislit collimator. The use of a multislit collimator necessitates a number of modifications to the standard compressed sensing reconstruction pipeline. In particular, we find that SparseCT reconstruction is feasible within a model-based image reconstruction framework that incorporates data fidelity weighting to consider penumbra effects and source jittering to consider the effect of partial source obstruction. Here, we present these modifications and demonstrate their application in simulations and real-world prototype scans. In simulations compared to conventional low-dose acquisitions, SparseCT is able to achieve smaller normalized root-mean square differences than tube-current reduction at larger dose reduction levels. In prototype experiments, we successfully apply our reconstruction modifications and maintain image resolution at the quarter-dose reduction level. The SparseCT design requires only small hardware modifications to current diagnostic clinical scanners, opening up new possibilities for CT dose reduction.

[1]  Patrick J. La Rivière,et al.  Penalized-likelihood sinogram restoration for computed tomography , 2006, IEEE Transactions on Medical Imaging.

[2]  Ricardo Otazo,et al.  SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction , 2017, Medical Imaging.

[3]  Daniel K Sodickson,et al.  SparseCT: System concept and design of multislit collimators. , 2019, Medical physics.

[4]  M. Defrise,et al.  An algorithm for total variation regularization in high-dimensional linear problems , 2011 .

[5]  Jeffrey A. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, IEEE Trans. Image Process..

[6]  Jeffrey A. Fessler,et al.  Relaxed Linearized Algorithms for Faster X-Ray CT Image Reconstruction , 2015, IEEE Transactions on Medical Imaging.

[7]  Lei Xing,et al.  Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints , 2012, Physics in medicine and biology.

[8]  Donald Geman,et al.  Stochastic Relaxation, Gibbs Distributions, and the Bayesian Restoration of Images , 1984, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[9]  M. Shiung,et al.  Development and Validation of a Practical Lower-Dose-Simulation Tool for Optimizing Computed Tomography Scan Protocols , 2012, Journal of computer assisted tomography.

[10]  Daniel Kolditz,et al.  Iterative reconstruction methods in X-ray CT. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[11]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[12]  Lei Zhu,et al.  Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies , 2013, Comput. Math. Methods Medicine.

[13]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[14]  Lin Fu,et al.  2.5D dictionary learning based computed tomography reconstruction , 2016, SPIE Defense + Security.

[15]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[16]  Baiyu Chen,et al.  Low‐dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge , 2017, Medical physics.

[17]  David Faul,et al.  Joint reconstruction of simultaneously acquired MR-PET data with multi sensor compressed sensing based on a joint sparsity constraint , 2014, EJNMMI Physics.

[18]  Jeffrey A. Fessler,et al.  3D Forward and Back-Projection for X-Ray CT Using Separable Footprints , 2010, IEEE Transactions on Medical Imaging.

[19]  Thomas Kosters,et al.  EMRECON: An expectation maximization based image reconstruction framework for emission tomography data , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[20]  Zhengrong Liang,et al.  Guest Editorial Low-Dose CT: What Has Been Done, and What Challenges Remain? , 2017, IEEE Trans. Medical Imaging.

[21]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[22]  Sajid Abbas,et al.  Effects of sparse sampling schemes on image quality in low-dose CT. , 2013, Medical physics.

[23]  Alvaro R. De Pierro,et al.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography , 1995, IEEE Trans. Medical Imaging.

[24]  Lei Zhu,et al.  Scatter correction for cone-beam CT in radiation therapy. , 2009 .

[25]  Patrick J La Rivière,et al.  Joint reconstruction of multi-channel, spectral CT data via constrained total nuclear variation minimization , 2014, Physics in medicine and biology.

[26]  Jeffrey A. Fessler,et al.  Combining Ordered Subsets and Momentum for Accelerated X-Ray CT Image Reconstruction , 2015, IEEE Transactions on Medical Imaging.

[27]  Rainer Raupach,et al.  Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule Detection: First Performance Evaluation of Single Energy Scanning With Spectral Shaping , 2014, Investigative radiology.

[28]  Changhwan Kim,et al.  A Feasibility Study of Low-Dose Single-Scan Dual-Energy Cone-Beam CT in Many-View Under-Sampling Framework , 2017, IEEE Transactions on Medical Imaging.

[29]  Zhengrong Liang,et al.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction , 2012, Physics in medicine and biology.

[30]  Jingyan Xu,et al.  Electronic Noise Modeling in Statistical Iterative Reconstruction , 2009, IEEE Transactions on Image Processing.

[31]  E.J. Candes,et al.  An Introduction To Compressive Sampling , 2008, IEEE Signal Processing Magazine.

[32]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[33]  Jeffrey A. Fessler,et al.  Alternating Dual Updates Algorithm for X-ray CT Reconstruction on the GPU , 2015, IEEE Transactions on Computational Imaging.

[34]  Xiaochuan Pan,et al.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT , 2010, Physics in medicine and biology.