The resonant behavior of silicon tubes under two-phase microfluidic conditions with both microbeads and gas bubbles

Abstract This paper examines the behavior of the gain, Q and frequency of resonating microtubes during two-phase, both liquid–gas and liquid–solid, fluidic conditions. The presence of both gas bubbles and solid particles are found to shift the resonant frequency and dampen the resonator signal under static conditions. Going from air to a pure liquid depressed the resonator Q-value by 7–50%. The addition of a significant amount of a second phase, either gas or solid could depress the Q-value by 96% from that of the pure liquid filled resonator. New Q loss mechanisms for microresonators were uncovered, via either internal liquid damping or two-phase damping. Ferromagnetic beads in an external magnetic field are observed to have a significant, variable affect on the gain and Q of the resonator and bead motion of the vibrating microtube. A variety of sensor and transducer applications for the results will be discussed and include Coriolis mass flow, density, chemical concentration, lubricity and viscosity measurements, testing of slurries and carbonated or aerated liquids, mixing, and cell lysing.

[1]  Peter Enoksson,et al.  Fluid density sensor based on resonance vibration , 1995 .

[2]  P Belgrader,et al.  Lysing bacterial spores by sonication through a flexible interface in a microfluidic system. , 2001, Analytical chemistry.

[3]  Paul I. Lacey,et al.  Fuel Lubricity Reviewed , 1998 .

[4]  Manus P. Henry,et al.  A neural network to correct mass flow errors caused by two-phase flow in a digital coriolis mass flowmeter , 2001 .

[5]  Jin-Woo Choi,et al.  An integrated microfluidic biochemical detection system with magnetic bead-based sampling and analysis capabilities , 2001, Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090).

[6]  Sonbol Massoud-Ansari,et al.  A variable temperature, resonant density sensor made using an improved chip-level vacuum package , 2003 .

[7]  K. Widder,et al.  Magnetic guidance of drug‐carrying microspheres , 1978 .

[8]  N. D. Rooij,et al.  Very high Q-factor resonators in monocrystalline silicon , 1990 .

[9]  R. Zengerle,et al.  A unique solution for preventing clogging of flow channels by gas bubbles , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[10]  Goran Goranovic,et al.  The clogging pressure of bubbles in hydrophilic microchannel contractions , 2004 .

[11]  P. Ward,et al.  Quality factors of MEMS gyros and the role of thermoelastic damping , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[12]  R. Molday,et al.  Application of magnetic microspheres in labelling and separation of cells , 1977, Nature.

[13]  Peter Enoksson,et al.  A silicon resonant sensor structure for Coriolis mass-flow measurements , 1997 .

[14]  A. F Skea,et al.  Effects of gas leaks in oil flow on single-phase flowmeters , 1999 .

[15]  Sonbol Massoud-Ansari,et al.  Chip-level vacuum packaging of micromachines using NanoGetters , 2003 .

[16]  T. Tsong,et al.  Formation and resealing of pores of controlled sizes in human erythrocyte membrane , 1977, Nature.