Single-pulse CARS based multimodal nonlinear optical microscope for bioimaging.

Noninvasive label-free imaging of biological systems raises demand not only for high-speed three-dimensional prescreening of morphology over a wide-field of view but also it seeks to extract the microscopic functional and molecular details within. Capitalizing on the unique advantages brought out by different nonlinear optical effects, a multimodal nonlinear optical microscope can be a powerful tool for bioimaging. Bringing together the intensity-dependent contrast mechanisms via second harmonic generation, third harmonic generation and four-wave mixing for structural-sensitive imaging, and single-beam/single-pulse coherent anti-Stokes Raman scattering technique for chemical sensitive imaging in the finger-print region, we have developed a simple and nearly alignment-free multimodal nonlinear optical microscope that is based on a single wide-band Ti:Sapphire femtosecond pulse laser source. Successful imaging tests have been realized on two exemplary biological samples, a canine femur bone and collagen fibrils harvested from a rat tail. Since the ultra-broad band-width femtosecond laser is a suitable source for performing high-resolution optical coherence tomography, a wide-field optical coherence tomography arm can be easily incorporated into the presented multimodal microscope making it a versatile optical imaging tool for noninvasive label-free bioimaging.

[1]  Wei Zheng,et al.  Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth , 2015 .

[2]  Y. Silberberg,et al.  Hybrid single-source online Fourier transform coherent anti-Stokes Raman scattering/optical coherence tomography. , 2014, Optics letters.

[3]  Wei Zheng,et al.  Multimodal nonlinear optical microscopic imaging provides new insights into acetowhitening mechanisms in live mammalian cells without labeling. , 2014, Biomedical optics express.

[4]  M. Gruebele,et al.  Nonlinear Interferometric Vibrational Imaging and Spectroscopy , 2014 .

[5]  A. Stolow,et al.  Multimodal Nonlinear Optical Microscopy: From Biophotonics to Geophotonics , 2014 .

[6]  Hiroaki Maekawa,et al.  Mapping molecular orientation with phase sensitive vibrationally resonant sum-frequency generation microscopy. , 2013, The journal of physical chemistry. B.

[7]  Cnrs Fre,et al.  Characterization of Type I and IV Collagens by Raman Microspectroscopy: Identification of Spectral Markers of the Dermo-Epidermal Junction , 2012 .

[8]  B. Dietzek,et al.  Raman and coherent anti-Stokes Raman scattering microspectroscopy for biomedical applications. , 2012, Journal of biomedical optics.

[9]  N. Timofeeva,et al.  Observations of multiscale, stress-induced changes of collagen orientation in tendon by polarized Raman spectroscopy. , 2011, Biomacromolecules.

[10]  Nien-Hui Ge,et al.  Rapid vibrational imaging with sum frequency generation microscopy. , 2011, Optics letters.

[11]  Y. G. Houssen,et al.  Monitoring micrometer-scale collagen organization in rat-tail tendon upon mechanical strain using second harmonic microscopy. , 2011, Journal of biomechanics.

[12]  Ji-Xin Cheng,et al.  Multimodal nonlinear optical microscopy , 2011, Laser & photonics reviews.

[13]  J. Dunlop,et al.  Characterization of the Spatial Arrangement of Secondary Osteons in the Diaphysis of Equine and Canine Long Bones , 2011, Anatomical record.

[14]  L. Lucas,et al.  Surface-sensitive Raman spectroscopy of collagen I fibrils. , 2011, Biophysical journal.

[15]  Ji-Xin Cheng,et al.  Shedding new light on lipid biology with coherent anti-Stokes Raman scattering microscopy , 2010, Journal of Lipid Research.

[16]  Hervé Rigneault,et al.  High order symmetry structural properties of vibrational resonances using multiple-field polarization coherent anti-Stokes Raman spectroscopy microscopy. , 2010, Physical review letters.

[17]  Moshe Levi,et al.  Multimodal CARS microscopy determination of the impact of diet on macrophage infiltration and lipid accumulation on plaque formation in ApoE-deficient mice[S] , 2010, Journal of Lipid Research.

[18]  Mary-Ann Mycek,et al.  Quantitative polarized Raman spectroscopy in highly turbid bone tissue. , 2010, Journal of biomedical optics.

[19]  Yaron Silberberg,et al.  Single-beam coherent Raman spectroscopy and microscopy via spectral notch shaping. , 2010, Optics express.

[20]  Ji‐Xin Cheng,et al.  Imaging growth of neurites in conditioned hydrogel by coherent anti-Stokes Raman scattering microscopy , 2009, Organogenesis.

[21]  Wolfgang Werner Langbein,et al.  Single source coherent anti-Stokes Raman microspectroscopy using spectral focusing , 2009 .

[22]  Ji-Xin Cheng,et al.  High-speed vibrational imaging and spectral analysis of lipid bodies by compound Raman microscopy. , 2009, The journal of physical chemistry. B.

[23]  Wei Min,et al.  Near-degenerate four-wave-mixing microscopy. , 2009, Nano letters.

[24]  Andrew Ridsdale,et al.  Optimally chirped multimodal CARS microscopy based on a single Ti:sapphire oscillator. , 2009, Optics express.

[25]  P. R. van Weeren,et al.  Changes in subchondral bone mineral density and collagen matrix organization in growing horses. , 2008, Bone.

[26]  Jane A Dickerson,et al.  Current Applications of Liquid Chromatography / Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation , 2008 .

[27]  Stephen T. C. Wong,et al.  Chemically-selective imaging of brain structures with CARS microscopy. , 2007, Optics express.

[28]  T. Irving,et al.  Microfibrillar structure of type I collagen in situ. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[29]  Zhongping Chen,et al.  Second harmonic optical coherence tomography , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  S. Boppart,et al.  Nonlinear optical contrast enhancement for optical coherence tomography. , 2003, Optics express.

[31]  Leslie M Loew,et al.  Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms , 2003, Nature Biotechnology.

[32]  W. Webb,et al.  Nonlinear magic: multiphoton microscopy in the biosciences , 2003, Nature Biotechnology.

[33]  Yaron Silberberg,et al.  Single-pulse coherent anti-Stokes Raman spectroscopy in the fingerprint spectral region , 2003 .

[34]  P. Hansma,et al.  Investigations into the polymorphism of rat tail tendon fibrils using atomic force microscopy. , 2003, Biochemical and biophysical research communications.

[35]  A. Fercher,et al.  Optical coherence tomography - principles and applications , 2003 .

[36]  Yaron Silberberg,et al.  Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy , 2002, Nature.

[37]  D Yelin,et al.  Laser scanning third-harmonic-generation microscopy in biology. , 1999, Optics express.

[38]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[39]  M Deutsch,et al.  Connective tissue polarity. Optical second-harmonic microscopy, crossed-beam summation, and small-angle scattering in rat-tail tendon. , 1986, Biophysical journal.

[40]  A. Craig,et al.  Quantitative electron microscope observations of the collagen fibrils in rat‐tail tendon , 1977, Biopolymers.

[41]  A. Stolow,et al.  Multimodal Nonlinear Optical Microscopy , 2014 .

[42]  Ji-Xin Cheng,et al.  Coherent Raman Scattering Microscopy , 2011 .

[43]  M. Komorowska,et al.  Structural alteration of collagen fibres--spectroscopic and mechanical studies. , 2010, Acta of bioengineering and biomechanics.

[44]  Shuhua Yue,et al.  Shedding New Light on Lipid Biology with CARS Microscopy , 2010 .

[45]  Paul Roschger,et al.  From brittle to ductile fracture of bone , 2006, Nature materials.

[46]  A. Fabre,et al.  Imaging lipid bodies in cells and tissues using third-harmonic generation microscopy , 2005, Nature Methods.

[47]  T. Wess,et al.  Collagen fibril form and function. , 2005, Advances in protein chemistry.

[48]  X. Xie,et al.  Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications , 2004 .

[49]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.