Rapid antibiotic susceptibility testing in a microfluidic pH sensor.

For appropriate selection of antibiotics in the treatment of pathogen infection, rapid antibiotic susceptibility testing (AST) is urgently needed in clinical practice. This study reports the utilization of a microfluidic pH sensor for monitoring bacterial growth rate in culture media spiked with different kinds of antibiotics. The microfluidic pH sensor was fabricated by integration of pH-sensitive chitosan hydrogel with poly(dimethylsiloxane) (PDMS) microfluidic channels. For facilitating the reflectometric interference spectroscopic measurements, the chitosan hydrogel was coated on an electrochemically etched porous silicon chip, which was used as the substrate of the microfluidic channel. Real-time observation of the pH change in the microchannel can be realized by Fourier transform reflectometric interference spectroscopy (FT-RIFS), in which the effective optical thickness (EOT) was selected as the optical signal for indicating the reversible swelling process of chitosan hydrogel stimulated by pH change. With this microfluidic pH sensor, we demonstrate that confinement of bacterial cells in a nanoliter size channel allows rapid accumulation of metabolic products and eliminates the need for long-time preincubation, thus reducing the whole detection time. On the basis of this technology, the whole bacterial growth curve can be obtained in less than 2 h, and consequently rapid AST can be realized. Compared with conventional methods, the AST data acquired from the bacterial growth curve can provide more detailed information for studying the antimicrobial behavior of antibiotics during different stages. Furthermore, the new technology also provides a convenient method for rapid minimal inhibition concentration (MIC) determination of individual antibiotics or the combinations of antibiotics against human pathogens that will find application in clinical and point-of-care medicine.

[1]  D. Mannino,et al.  The epidemiology of sepsis in the United States from 1979 through 2000. , 2003, The New England journal of medicine.

[2]  M. Burns,et al.  Asynchronous magnetic bead rotation (AMBR) biosensor in microfluidic droplets for rapid bacterial growth and susceptibility measurements. , 2011, Lab on a chip.

[3]  S. Cosgrove,et al.  Comparison of mortality associated with methicillin-resistant and methicillin-susceptible Staphylococcus aureus bacteremia: a meta-analysis. , 2003, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[4]  M. Mcmurdo,et al.  Characterization of Bacterial Communities in Feces from Healthy Elderly Volunteers and Hospitalized Elderly Patients by Using Real-Time PCR and Effects of Antibiotic Treatment on the Fecal Microbiota , 2004, Applied and Environmental Microbiology.

[5]  Nate J. Cira,et al.  A self-loading microfluidic device for determining the minimum inhibitory concentration of antibiotics. , 2012, Lab on a chip.

[6]  Vincent Gau,et al.  Antimicrobial susceptibility testing using high surface-to-volume ratio microchannels. , 2010, Analytical chemistry.

[7]  Mehmet Toner,et al.  Asymmetry and Aging of Mycobacterial Cells Lead to Variable Growth and Antibiotic Susceptibility , 2012, Science.

[8]  M. Ghadiri,et al.  A porous silicon-based optical interferometric biosensor. , 1997, Science.

[9]  Roberta B Carey,et al.  Methicillin-resistant S. aureus infections among patients in the emergency department. , 2006, The New England journal of medicine.

[10]  E. Segal,et al.  Preparation and Characterization of a pH‐ and Thermally Responsive Poly(N‐isopropylacrylamide‐co‐acrylic acid)/Porous SiO2 Hybrid , 2010, Advanced functional materials.

[11]  Cees Dekker,et al.  Bacterial growth and motility in sub-micron constrictions , 2009, Proceedings of the National Academy of Sciences.

[12]  Jeffrey S. Moore,et al.  Fast pH- and Ionic Strength-Responsive Hydrogels in Microchannels , 2001 .

[13]  R. Ohashi,et al.  Further biocompatibility testing of silica-chitosan complex membrane in the production of tissue plasminogen activator by epithelial and fibroblast cells. , 1999, Journal of bioscience and bioengineering.

[14]  D. Beebe,et al.  Microenvironment design considerations for cellular scale studies. , 2004, Lab on a chip.

[15]  Kanji Tsuru,et al.  Novel approach to fabricate porous gelatin-siloxane hybrids for bone tissue engineering. , 2002, Biomaterials.

[16]  Qin Tu,et al.  High-throughput microfluidic system for long-term bacterial colony monitoring and antibiotic testing in zero-flow environments. , 2011, Biosensors & bioelectronics.

[17]  Michael J. Sailor,et al.  Chitosan Hydrogel‐Capped Porous SiO2 as a pH Responsive Nano‐Valve for Triggered Release of Insulin , 2009 .

[18]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[19]  Hongkai Wu,et al.  A scalable microfluidic chip for bacterial suspension culture. , 2011, Lab on a chip.

[20]  C. Salgado,et al.  The association between antibiotic use and resistance: the role of secondary antibiotics , 2010, European Journal of Clinical Microbiology & Infectious Diseases.

[21]  S. Quake,et al.  Long-Term Monitoring of Bacteria Undergoing Programmed Population Control in a Microchemostat , 2005, Science.

[22]  P. V. Havaldar,et al.  Diphtheritic myocarditis: clinical and laboratory parameters of prognosis and fatal outcome , 2000, Annals of tropical paediatrics.

[23]  Ursula Obst,et al.  Detection of antibiotic-resistant bacteria and their resistance genes in wastewater, surface water, and drinking water biofilms. , 2003, FEMS microbiology ecology.

[24]  N. Prasadarao,et al.  Outer membrane protein A and OprF: versatile roles in Gram‐negative bacterial infections , 2012, The FEBS journal.

[25]  I. Peitz,et al.  Single-cell bacteria growth monitoring by automated DEP-facilitated image analysis. , 2010, Lab on a chip.

[26]  Robin H. Liu,et al.  Functional hydrogel structures for autonomous flow control inside microfluidic channels , 2000, Nature.

[27]  S. Gunasekaran,et al.  Selected properties of pH‐sensitive, biodegradable chitosan–poly(vinyl alcohol) hydrogel , 2004 .

[28]  R. Ismagilov,et al.  Microfluidic confinement of single cells of bacteria in small volumes initiates high-density behavior of quorum sensing and growth and reveals its variability. , 2009, Angewandte Chemie.

[29]  Peng Chen,et al.  Detecting metabolic activities of bacteria using a simple carbon nanotube device for high-throughput screening of anti-bacterial drugs. , 2011, Biosensors & bioelectronics.

[30]  Nate J. Cira,et al.  Rapid Identification of ESKAPE Bacterial Strains Using an Autonomous Microfluidic Device , 2012, PloS one.