Breast ultrasound tomography with two parallel transducer arrays

Breast ultrasound tomography is an emerging imaging modality to reconstruct the sound speed, density, and ultrasound attenuation of the breast in addition to ultrasound reflection/beamforming images for breast cancer detection and characterization. We recently designed and manufactured a new synthetic-aperture breast ultrasound tomography prototype with two parallel transducer arrays consisting of a total of 768 transducer elements. The transducer arrays are translated vertically to scan the breast in a warm water tank from the chest wall/axillary region to the nipple region to acquire ultrasound transmission and reflection data for whole-breast ultrasound tomography imaging. The distance of these two ultrasound transducer arrays is adjustable for scanning breasts with different sizes. We use our breast ultrasound tomography prototype to acquire phantom and in vivo patient ultrasound data to study its feasibility for breast imaging. We apply our recently developed ultrasound imaging and tomography algorithms to ultrasound data acquired using our breast ultrasound tomography system. Our in vivo patient imaging results demonstrate that our breast ultrasound tomography can detect breast lesions shown on clinical ultrasound and mammographic images.

[1]  S. L. Lee,et al.  Algebraic Reconstruction of Spatial Distributions of Acoustic Absorption within Tissue from Their Two-Dimensional Acoustic Projections , 1974 .

[2]  J. Greenleaf,et al.  ALGEBRAIC RECONSTRUCTION OF SPATIAL DISTRIBUTIONS OF ACOUSTIC VELOCITIES IN TISSUE FROM THEIR TIME-OF-FLIGHT PROFILES. , 1975 .

[3]  T. V. Oughton,et al.  Breast imaging in coronal planes with simultaneous pulse echo and transmission ultrasound. , 1981, Science.

[4]  M. O'Donnell,et al.  Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  T. D. Mast,et al.  An ultrasonic ring transducer system for studies of scattering and imaging , 1996 .

[6]  P. Stomper,et al.  Analysis of parenchymal density on mammograms in 1353 women 25-79 years old. , 1996, AJR. American journal of roentgenology.

[7]  Phyllis J. Kornguth,et al.  Pain during mammography: characteristics and relationship to demographic and medical variables , 1996, PAIN®.

[8]  D. Borup,et al.  Inverse scattering from arbitrary two-dimensional objects in stratified environments via a Green’s operator , 1997 .

[9]  D. A. Palmer,et al.  High‐speed data acquisition in a diffraction tomography system employing large‐scale toroidal arrays , 1997 .

[10]  G.R. Lockwood,et al.  Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  J. A. Jensen,et al.  Recursive ultrasound imaging , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[12]  T. M. Kolb,et al.  Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. , 2002, Radiology.

[13]  Svetoslav Ivanov Nikolov,et al.  Synthetic aperture tissue and flow ultrasound imaging , 2002 .

[14]  N. Duric,et al.  Computerized Ultrasound Risk Evaluation (CURE) System: Development of Combined Transmission and Reflection Ultrasound with New Reconstruction Algorithms for Breast Imaging , 2002 .

[15]  Peter J. Littrup,et al.  Characterizing tissue with acoustic parameters derived from ultrasound data , 2002, SPIE Medical Imaging.

[16]  Peter J. Littrup,et al.  Ultrasound tomography of breast tissue , 2003, SPIE Medical Imaging.

[17]  Peter J. Littrup,et al.  Ultrasonic breast imaging using a wave-equation migration method , 2003, SPIE Medical Imaging.

[18]  Tae-Seong Kim,et al.  High-resolution ultrasound transmission tomography , 2003, SPIE Medical Imaging.

[19]  J.A. Jensen,et al.  Ultrasound research scanner for real-time synthetic aperture data acquisition , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  F. Simonetti,et al.  Multiple scattering: the key to unravel the subwavelength world from the far-field pattern of a scattered wave. , 2006, Physical review. E, Statistical, nonlinear, and soft matter physics.

[21]  J.T. Yen,et al.  2-D array for 3-D ultrasound imaging using synthetic aperture techniques , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Jørgen Arendt Jensen,et al.  Synthetic aperture ultrasound imaging. , 2006, Ultrasonics.

[23]  Peter J. Littrup,et al.  Breast imaging with time-reversed ultrasound , 2006, SPIE Medical Imaging.

[24]  Youli Quan,et al.  Sound-speed tomography using first-arrival transmission ultrasound for a ring array , 2007, SPIE Medical Imaging.

[25]  N. Duric,et al.  Detection of breast cancer with ultrasound tomography: first results with the Computed Ultrasound Risk Evaluation (CURE) prototype. , 2007, Medical physics.

[26]  Youli Quan,et al.  Ultrasound pulse-echo imaging using the split-step Fourier propagator , 2007, SPIE Medical Imaging.

[27]  Neb Duric,et al.  Sound-speed and attenuation imaging of breast tissue using waveform tomography of transmission ultrasound data , 2007, SPIE Medical Imaging.

[28]  Olsi Rama,et al.  COMPUTERIZED ULTRASOUND RISK EVALUATION (CURE): FIRST CLINICAL RESULTS , 2007 .

[29]  F Simonetti,et al.  Imaging beyond the Born approximation: an experimental investigation with an ultrasonic ring array. , 2007, Physical review. E, Statistical, nonlinear, and soft matter physics.

[30]  Neb Duric,et al.  Globally optimized Fourier finite-difference method for ultrasound breast imaging , 2008, SPIE Medical Imaging.

[31]  Lianjie Huang,et al.  From beamforming to diffraction tomography , 2008 .

[32]  Neb Duric,et al.  Comparison of ultrasound attenuation tomography methods for breast imaging , 2008, SPIE Medical Imaging.

[33]  Neb Duric,et al.  Clinical breast imaging using sound-speed reconstructions of ultrasound tomography data , 2008, SPIE Medical Imaging.

[34]  Haijiang Zhang,et al.  An improved automatic time-of-flight picker for medical ultrasound tomography. , 2009, Ultrasonics.

[35]  N. Duric,et al.  In vivo breast sound-speed imaging with ultrasound tomography. , 2009, Ultrasound in medicine & biology.

[36]  J. Jensen,et al.  Three-dimensional synthetic aperture focusing using a rocking convex array transducer , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[37]  Svetoslav Ivanov Nikolov,et al.  Practical applications of synthetic aperture imaging , 2010, 2010 IEEE International Ultrasonics Symposium.

[38]  Peter Huthwaite,et al.  Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study , 2010, Medical Imaging.

[39]  Lianjie Huang,et al.  Detecting small targets using windowed time-reversal MUSIC imaging: A phantom study , 2011, 2011 IEEE International Ultrasonics Symposium.

[40]  Francesco Simonetti,et al.  High-resolution imaging with a real-time synthetic aperture ultrasound system: a phantom study , 2011, Medical Imaging.

[41]  H. Gemmeke,et al.  3D ultrasound computer tomography of the breast: a new era? , 2012, European journal of radiology.

[42]  Lianjie Huang,et al.  Ultrasound time-reversal MUSIC imaging with diffraction and attenuation compensation , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[43]  Zhigang Zhang,et al.  Ultrasound waveform tomography with the total-variation regularization for detection of small breast tumors , 2012, Medical Imaging.

[44]  Lianjie Huang,et al.  Ultrasound imaging of extended targets using a windowed time-reversal MUSIC method , 2012, Medical Imaging.

[45]  Zhigang Zhang,et al.  Efficient implementation of ultrasound waveform tomography using source encoding , 2012, Medical Imaging.

[46]  Yassin Labyed,et al.  Ultrasound time-reversal MUSIC imaging of extended targets. , 2012, Ultrasound in medicine & biology.

[47]  Lianjie Huang,et al.  Detection of breast microcalcifications using synthetic-aperture ultrasound , 2012, Medical Imaging.

[48]  Lianjie Huang,et al.  Ultrasound waveform tomography using wave-energy-based preconditioning , 2013, Medical Imaging.

[49]  Lianjie Huang,et al.  Ultrasound waveform tomography with a modified total-variation regularization scheme , 2013, Medical Imaging.

[50]  Lianjie Huang,et al.  Super-resolution ultrasound imaging using a phase-coherent MUSIC method with compensation for the phase response of transducer elements , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[51]  Kenneth M. Hanson,et al.  Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study , 2013, Medical Imaging.

[52]  Zhigang Zhang,et al.  Efficient implementation of ultrasound waveform tomography using data blending , 2014, Medical Imaging.

[53]  Kenneth M. Hanson,et al.  Breast ultrasound waveform tomography: using both transmission and reflection data, and numerical virtual point sources , 2014, Medical Imaging.

[54]  Lianjie Huang,et al.  TR-MUSIC inversion of the density and compressibility contrasts of point scatterers , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[55]  Lianjie Huang,et al.  Toward real-time bent-ray breast ultrasound tomography using GPUs , 2014, Medical Imaging.

[56]  N. Duric,et al.  Clinical breast imaging with ultrasound tomography: A description of the SoftVue system , 2014 .

[57]  Lianjie Huang,et al.  Ultrasound waveform tomography with a spatially variant regularization scheme , 2014, Medical Imaging.

[58]  Lianjie Huang,et al.  Ultrasound bent-ray tomography using both transmission and reflection data , 2014, Medical Imaging.

[59]  Junseob Shin,et al.  Ultrasound bent-ray tomography with a modified total-variation regularization scheme , 2013, Medical Imaging.

[60]  Junseob Shin,et al.  Breast ultrasound tomography with two parallel transducer arrays: preliminary clinical results , 2015, Medical Imaging.

[61]  Junseob Shin,et al.  Ultrasound transmission attenuation tomography using energy-scaled amplitude ratios , 2016, SPIE Medical Imaging.

[62]  Lianjie Huang,et al.  Ultrasound waveform tomography with the second-order total-generalized-variation regularization , 2016, SPIE Medical Imaging.