Reactive power optimization strategy considering analytical impedance ratio with wind power

In this paper, considering the traditional reactive power optimization cannot realize the continuous voltage adjustment and voltage stability, a dynamic reactive power optimization strategy is proposed in order to achieve both the minimization of network loss and high voltage stability with wind power. Due to the fact that wind power generation is fluctuant and uncertain, electrical equipments such as transformers and shunt capacitors may be operated frequently in order to achieve minimization of network loss, which affect the lives of these devices. In order to solve this problem, this paper introduces the derivation process of analytical impedance ratio based on Thevenin equivalent. Thus, the multiple objective function is proposed to minimize the network loss and analytical impedance ratio. Finally, taking the improved IEEE 33-bus distribution system as example, the result shows that the movement of voltage control equipment has been reduced and network loss increment is controlled at the same time, which proves the applicable value of this strategy.

[1]  Paul Giorsetto,et al.  Development of a New Procedure for Reliability Modeling of Wind Turbine Generators , 1983, IEEE Transactions on Power Apparatus and Systems.

[2]  P. Kundur,et al.  Power system stability and control , 1994 .

[3]  A.A. Chowdhury,et al.  Reliability models for large wind farms in generation system planning , 2005, IEEE Power Engineering Society General Meeting, 2005.

[4]  Li Zhimin An Analytical Method for Online Identification and Control of Voltage Weak Buses , 2012 .

[5]  Duan Xian-zhong Reactive Power Optimization in Distribution System With Wind Power Generators , 2008 .

[6]  M.A. Matos,et al.  Operational reserve of a power system with a large amount of wind power , 2004, 2004 International Conference on Probabilistic Methods Applied to Power Systems.

[7]  Li Yongan,et al.  Optimal Reactive Power Planning of Radial Distribution Systems with Distributed Generation , 2013, 2013 Third International Conference on Intelligent System Design and Engineering Applications.

[8]  Zheng Yong-wei Reactive power optimization strategy in distribution network with wind farm , 2013 .

[9]  Tongwen Chen,et al.  Investigation on the thevenin equivalent parameters for online estimation of maximum power transfer limits , 2010 .

[10]  Singh Maninder IEEE Reliability Test System (RTS) of 1996 (Available in Hypersim) , 2016 .

[11]  Xinchao Wang,et al.  Reactive power optimization for distribution system with distributed generations based on AHSPSO algorithm , 2016, 2016 China International Conference on Electricity Distribution (CICED).