Absolute quantification of regional myocardial uptake of 99mTc-sestamibi with SPECT: experimental validation in a porcine model.

UNLABELLED We have evaluated a method for absolute in vivo quantification of 99mTc-sestamibi uptake in a porcine model of myocardial perfusion. METHODS Correlated CT and radionuclide images were obtained from eight adult pigs using a combined CT-SPECT imaging system. In each case, the CT image is used to generate an object-specific attenuation map that is incorporated into an iterative algorithm for reconstruction and attenuation correction of the radionuclide image. Anatomic information available from the correlated CT image is used to correct the radionuclide image for partial-volume errors by mathematically modeling the radionuclide imaging process. A volume of interest, or template, that approximates the geometric extent of the myocardium is defined from the CT image. Once defined, the template is assigned unit activity and is mathematically projected using a realistic physical model of the radionuclide imaging process including nonideal collimation and object-specific attenuation. The template is then reconstructed from these projections to obtain a pixel-by-pixel partial-volume correction for the myocardium in the radionuclide image. The CT image is also used to delimit the anatomic boundaries of the myocardium for quantification of the radionuclide images. The pixel intensities in the corrected radionuclide image are calibrated in units of activity concentration (MBq/g) and compared with the ex vivo activity concentration measured directly from the excised myocardium. RESULTS Without corrections, the measured in vivo activity concentration in the porcine myocardium was only 10% of the true value. Correcting for object-specific attenuation improved the accuracy of this measurement but resulted in values that were still only 42% of the true value. By correcting for both attenuation and partial-volume errors, we were able to achieve absolute quantification with an accuracy error near 10%. CONCLUSION We have shown that, by applying object-specific attenuation corrections and suitable partial-volume corrections, absolute regional activity concentration can be measured accurately in the porcine myocardium.

[1]  I. Hutton,et al.  Balanced triple-vessel disease: enhanced detection by estimated myocardial thallium uptake. , 1992, Nuclear medicine communications.

[2]  R. Jaszczak,et al.  Improved SPECT quantification using compensation for scattered photons. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Ronald J. Jaszczak,et al.  Physical Factors Affecting Quantitative Measurements Using Camera-Based Single Photon Emission Computed Tomography (Spect) , 1981, IEEE Transactions on Nuclear Science.

[4]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[5]  M. Schwaiger,et al.  Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  M S Rosenthal,et al.  Quantitative SPECT imaging: a review and recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  B H Hasegawa,et al.  Myocardial perfusion imaging with a combined x-ray CT and SPECT system. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Soo Chin Liew,et al.  Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT , 1993, IEEE Transactions on Nuclear Science.

[9]  G.T. Gullberg,et al.  Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[10]  R. Kessler,et al.  Analysis of emission tomographic scan data: limitations imposed by resolution and background. , 1984, Journal of computer assisted tomography.

[11]  Jerry L Prince,et al.  Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume Effects , 1992, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  B. H. Hasegawa,et al.  Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment , 1995 .

[13]  G. Hutchins,et al.  Circumferential wall thickness measurements of the human left ventricle: reference data for thallium-201 single-photon emission computed tomography. , 1986, The American journal of cardiology.

[14]  Implementation of a combined X-ray CT-scintillation camera imaging system for localizing and measuring radionuclide uptake: experiments in phantoms and patients , 1998 .

[15]  Jonathan M. Links,et al.  MR-Based Correction of Brain PET Measurements for Heterogeneous Gray Matter Radioactivity Distribution , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[16]  Bruce H. Hasegawa,et al.  Absolute quantitation of myocardial activity in phantoms , 1998 .

[17]  S L Bacharach,et al.  Artifactual inhomogeneities in myocardial PET and SPECT scans in normal subjects. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Michael E. Phelps,et al.  Quantitation in Positron Emission Computed Tomography , 1980 .

[19]  B. H. Hasegawa,et al.  Investigation of the use of X-ray CT images for attenuation compensation in SPECT , 1994 .

[20]  D S Berman,et al.  Quantification of rotational thallium-201 myocardial tomography. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  M E Phelps,et al.  Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  Bruce H. Hasegawa,et al.  Development of an emission-transmission CT system combining X-ray CT and SPECT , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[23]  J R Galt,et al.  Effects of myocardial wall thickness on SPECT quantification. , 1990, IEEE transactions on medical imaging.

[24]  Koichi Ogawa,et al.  Quantitative image reconstruction using position-dependent scatter correction in single photon emission CT , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[25]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.