Transient stability of power systems with high penetration of DFIG based wind farms

In this paper, the Doubly-fed Induction Generator (DFIG) for transient stability evaluations of power systems was systematically discussed, and the impacts of grid-connected large DFIG based wind farms on power system transient stability were then studied in detail. In the modeling of DFIG, an equivalent generator model was employed to reflect the combined behavior of the DFIG and its rotor converter. Furthermore, the control strategy of rotor-side converter, which was for the decoupled controls of the stator active and reactive power, was considered. The corresponding numerical simulations were carried out to explore and exploit the influences and interactions between synchronous generators and wind farm respectively on power system transient stability. In particular, different synchronous generator dynamic models and load models are considered during the simulation comparisons. Finally, some meaningful conclusions and comments are given in this paper.

[1]  P. Kundur,et al.  Power system stability and control , 1994 .

[2]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .

[3]  P. Ledesma,et al.  Transient stability studies in grids with great wind power penetration. Modelling issues and operation requirements , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[4]  N.W. Miller,et al.  Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[5]  Janaka Ekanayake,et al.  Dynamic modeling of doubly fed induction generator wind turbines , 2003 .

[6]  H.H. Zurn,et al.  Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids , 2004, IEEE Transactions on Energy Conversion.

[7]  M.V.A. Nunes,et al.  Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids , 2004 .

[8]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[9]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[10]  S.M. Muyeen,et al.  Transient Stability Analysis of Wind Generator System with the Consideration of Multi-Mass Shaft Model , 2005, 2005 International Conference on Power Electronics and Drives Systems.

[11]  A. Mullane,et al.  Modeling of the wind turbine with a doubly fed induction generator for grid integration studies , 2006, IEEE Transactions on Energy Conversion.

[12]  M. O'Malley,et al.  Wind generation, power system operation, and emissions reduction , 2006, IEEE Transactions on Power Systems.

[13]  Haritza Camblong,et al.  Connection requirements for wind farms : A survey on technical requierements and regulation , 2007 .

[14]  Yixin Ni,et al.  Modelling analysis of transient stability simulation with high penetration of grid‐connected wind farms of DFIG type , 2007 .