Accelerometer type cardiac transducer for detection of low-level heart sounds

The authors compare several different cardiac transducers and describe the development of a low-mass, accelerometer-type cardiac transducer which fulfils these objectives. The accelerometer weighs approximately 5 g and has a theoretical sensitivity of 125 mV/g in the frequency range 200-800 Hz. The basic design allows for easy modification of sensitivity and resonant frequency. This transducer has been effective in detecting sound associated with turbulent blood flow in partially occluded coronary arteries.<<ETX>>

[1]  C. Oakley,et al.  Diastolic murmur of coronary artery stenosis. , 1973, British heart journal.

[2]  J. Fredberg Pseudo-sound generation at atherosclerotic constrictions in arteries. , 1974, Bulletin of mathematical biology.

[3]  R. Lees,et al.  Evaluation of carotid stenosis by phonoangiography. , 1975, The New England journal of medicine.

[4]  D H Blankenhorn,et al.  Phonoangiography by Autocorrelation , 1977, Circulation.

[5]  Louis-Gilles Durand,et al.  FFT Techniques for the Spectral Analysis of Prosthetic Heart Valve Sounds , 1980 .

[6]  F S Barnes,et al.  Improved phonocardiogram system based on acoustic impedance matching. , 1980, The American journal of physiology.

[7]  D. Giddens,et al.  Characterization and evolution poststenotic flow disturbances. , 1981, Journal of biomechanics.

[8]  Lees Rs,et al.  Noninvasive diagnosis of arterial disease. , 1982 .

[9]  J. Kostis,et al.  Coronary Artery Disease - Correlates Between Diastolic Auditory Characteristics and Coronary Artery Stenoses , 1983, IEEE Transactions on Biomedical Engineering.

[10]  H N Sabbah,et al.  Frequency spectra of the first heart sound and of the aortic component of the second heart sound in patients with degenerated porcine bioprosthetic valves. , 1984, The American journal of cardiology.

[11]  Rafael Beyar,et al.  Heart-Sound Processing by Average and Variance Calculation - Physiologic Basic and Clinical Implications , 1984, IEEE Transactions on Biomedical Engineering.

[12]  Robert Guardo,et al.  Modeling of the Transfer Function of the Heart-Thorax Acoustic System in Dogs , 1985, IEEE Transactions on Biomedical Engineering.

[13]  D. G. Talbert,et al.  Wide Bandwidlt Fetal Phonography Using a Sensor Matched to the Compliance of the Mother's Abdominal Wall , 1986, IEEE Transactions on Biomedical Engineering.

[14]  H Vermariën,et al.  Quantification of the influence of mass and contact diameter of phonocardiographic transducers on high frequency heart sound recordings. , 1986, Acta cardiologica.

[15]  John L. Semmlow,et al.  Comparative evaluation of cardiac microphones , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  John L. Semmlow,et al.  High sensitivity PCG transducer for extended frequency applications , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[17]  J. Semmlow,et al.  Modeling sound generation in stenosed coronary arteries , 1990, IEEE Transactions on Biomedical Engineering.

[18]  J. Semmlow,et al.  Noninvasive detection of coronary stenoses before and after angioplasty using eigenvector methods , 1990, IEEE Transactions on Biomedical Engineering.

[19]  W. Welkowitz,et al.  Detection of coronary occlusions using autoregressive modeling of diastolic heart sounds , 1990, IEEE Transactions on Biomedical Engineering.

[20]  Metin Akay,et al.  Biomedical Instruments: Theory and Design , 1991 .