A study on the EMI in special power distribution zone on ship

Test standards for electrical and electronic equipment required for ship operations is applying the IEC-60533 standard. However, although a test procedure and a specified regulation are clearly defined in the deck and bridge zone and general power distribution zone, they are not regulated in the special power distribution zone with ship propulsion system. For these reasons, the costs for additional research and development have been invested. In this paper, we was measured power noise in a special power distribution zone in ship and we were compared and analyzed values measured. The actual experiments are performed on the ship of Korea Maritime and Ocean University. As a result, the acquired data on Hanbada shows that loop antenna with low frequency band(160kHz) and ultra log antenna with high frequency band(1.97GHz)occur about 6-8dB differences and about 8.7 difference respectively. Also, the acquired data on Hannara shows that each loop antenna of 1MHz, 11MHz, and 25MHz occurs about 7dB difference about 4-5dB differences respectively. so standard of Special distribution zone must be specified by comparative analysis of data obtained by the experiment more.