Ionophore-Based Voltammetric Ion Activity Sensing with Thin Layer Membranes.

As shown in recent work, thin layer ion-selective multi-ionophore membranes can be interrogated by cyclic voltammetry to detect the ion activity of multiple species simultaneously and selectively. Additional fundamental evidence is put forward on ion discrimination with thin multi-ionophore-based membranes with thicknesses of 200 ± 25 nm and backside contacted with poly-3-octylthiophene (POT). An anodic potential scan partially oxidizes the POT film (to POT(+)), thereby initiating the release of hydrophilic cations from the membrane phase to the sample solution at a characteristic potential. Varying concentration of added cation-exchanger demonstrates that it limits the ion transfer charge and not the deposited POT film. Voltammograms with multiple peaks are observed with each associated with the transfer of one type of ion (lithium, potassium, and sodium). Experimental conditions (thickness and composition of the membrane and concentration of the sample) are chosen that allow one to describe the system by a thermodynamic rather than kinetic model. As a consequence, apparent stability constants for sodium, potassium, and lithium (assuming 1:1 stoichiometry) with their respective ionophores are calculated and agree well with the values obtained by the potentiometric sandwich membrane technique. As an analytical application, a membrane containing three ionophores was used to determine lithium, sodium, and potassium in artificial samples at the same location and within a single voltammetric scan. Lithium and potassium were also determined in undiluted human plasma in the therapeutic concentration range.

[1]  M. Cuartero,et al.  Novel flow-through bulk optode for spectrophotometric determination of lithium in pharmaceuticals and saliva , 2010 .

[2]  Jidong Guo,et al.  Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support. , 2006, Analytical chemistry.

[3]  A. Bond,et al.  Applications of voltammetric ion selective electrodes to complex matrices , 2013 .

[4]  G. Horvai,et al.  PLASTICIZED POLY(VINYL CHLORIDE) PROPERTIES AND CHARACTERISTICS OF VALINOMYCIN ELECTRODES. 1. HIGH-FREQUENCY RESISTANCES AND DIELECTRIC PROPERTIES. , 1986 .

[5]  S. Amemiya,et al.  Extraction or adsorption? Voltammetric assessment of protamine transfer at ionophore-based polymeric membranes. , 2015, Analytical chemistry.

[6]  E. Bakker,et al.  Optical determination of ionophore diffusion coefficients in plasticized poly(vinyl chloride) sensing films , 2004 .

[7]  S. Amemiya,et al.  Subnanomolar detection limit of stripping voltammetric Ca²⁺-selective electrode: effects of analyte charge and sample contamination. , 2014, Analytical chemistry.

[8]  S. Amemiya,et al.  Voltammetric characterization of ion-ionophore complexation using thin polymeric membranes: asymmetric thin-layer responses. , 2015, Analytical chemistry.

[9]  Dongxue Han,et al.  Morphology of electrodeposited poly(3,4-ethylenedioxythiophene)/poly(4-styrene sulfonate) films , 2007 .

[10]  E. Bakker,et al.  Quantification of the concentration of ionic impurities in polymeric sensing membranes with the segmented sandwich technique. , 2001, Analytical Chemistry.

[11]  A. Bond,et al.  Voltammetric ion-selective electrodes for the selective determination of cations and anions. , 2010, Analytical chemistry.

[12]  E. Bakker,et al.  Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes. , 1999, Analytical chemistry.

[13]  Yushin Kim,et al.  Subnanomolar ion detection by stripping voltammetry with solid-supported thin polymeric membrane. , 2009, Analytical chemistry.

[14]  Yushin Kim,et al.  Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane. , 2008, Analytical chemistry.

[15]  F. Rius,et al.  A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood. , 2014, Lab on a chip.

[16]  G. Crespo,et al.  Chronopotentiometric carbonate detection with all-solid-state ionophore-based electrodes. , 2014, Analytical chemistry.

[17]  G. Crespo,et al.  All solid state chronopotentiometric ion-selective electrodes based on ferrocene functionalized PVC , 2013 .

[18]  S. Yamaguchi,et al.  Analysis for voltammetric responses of molecular-solid tetrathionaphthalene confined on an electrode. , 2011, Analytical chemistry.

[19]  Y. Umezawa,et al.  Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting KA,Bpot values (Technical Report) , 1995 .

[20]  E. Nemutlu,et al.  Determination of magnesium, calcium, sodium, and potassium in blood plasma samples by capillary zone electrophoresis , 2005, Analytical and bioanalytical chemistry.

[21]  Shaojun Dong,et al.  Conducting polymer polypyrrole supported bilayer lipid membranes. , 2005, Biosensors & bioelectronics.

[22]  E. Bakker,et al.  Determination of complex formation constants of 18 neutral alkali and alkaline earth metal ionophores in poly(vinyl chloride) sensing membranes plasticized with bis(2-ethylhexyl)sebacate and o-nitrophenyloctylether , 2000 .

[23]  Eric Bakker,et al.  Thin Layer Ionophore-Based Membrane for Multianalyte Ion Activity Detection. , 2015, Analytical chemistry.

[24]  P. Si,et al.  Thin layer electrochemical extraction of non-redoxactive cations with an anion-exchanging conducting polymer overlaid with a selective membrane. , 2009, Chemical communications.