Analysis of blood and tissue for amoxapine and trimipramine.

A method for the identification and quantitation of two tricyclic antidepressants, amoxapine (Asendin) and trimipramine (Surmontil) is presented here. Samples were extracted with hexane at pH 10, back-extracted with 1.0N sulfuric acid. The acidic layer was adjusted to pH 10 and re-extracted with hexane. Electron impact mass spectra were obtained. The base peak and molecular ion for amoxapine were at m/z 245 and 313, respectively. The base peak and molecular ion for trimipramine were at m/z 58 and 294, respectively. There were three forensic toxicology cases involving amoxapine in Cook County, IL, in 1980 and 1981. The concentrations of amoxapine in blood for these three cases were 1.66 mg/L, 7.16 mg/L, and 2.95 mg/L, respectively.

[1]  M. Schaffer,et al.  The general toxicology unknown. I. The systematic approach. , 1983, Journal of forensic sciences.

[2]  S. Rodgers,et al.  Physostigmine in amoxapine overdose. , 1981, American journal of hospital pharmacy.

[3]  D. Graves Phenytoin by volume-control set. , 1981, American journal of hospital pharmacy.

[4]  Smith Rs,et al.  A critical appraisal of amoxapine. , 1981 .

[5]  Settle Ec,et al.  Trimipramine: twenty years' worldwide clinical experience. , 1980 .

[6]  Kaumeier Hs,et al.  A double-blind comparison between amoxapine and amitriptyline in depressed in-patients. , 1980 .

[7]  D. Klein,et al.  A comparison of trimipramine and imipramine: a controlled study. , 1980, The Journal of clinical psychiatry.