Controlling a Human–Computer Interface System With a Novel Classification Method that Uses Electrooculography Signals

Electrooculography (EOG) signals can be used to control human-computer interface (HCI) systems, if properly classified. The ability to measure and process these signals may help HCI users to overcome many of the physical limitations and inconveniences in daily life. However, there are currently no effective multidirectional classification methods for monitoring eye movements. Here, we describe a classification method used in a wireless EOG-based HCI device for detecting eye movements in eight directions. This device includes wireless EOG signal acquisition components, wet electrodes and an EOG signal classification algorithm. The EOG classification algorithm is based on extracting features from the electrical signals corresponding to eight directions of eye movement (up, down, left, right, up-left, down-left, up-right, and down-right) and blinking. The recognition and processing of these eight different features were achieved in real-life conditions, demonstrating that this device can reliably measure the features of EOG signals. This system and its classification procedure provide an effective method for identifying eye movements. Additionally, it may be applied to study eye functions in real-life conditions in the near future.

[1]  S. Barattelli,et al.  Eye-movements as an input in human computer interaction: exploiting natural behaviour , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[2]  Hui Su,et al.  [Spatial and temporal characteristic of eye movement in human-computer interface design]. , 2003, Hang tian yi xue yu yi xue gong cheng = Space medicine & medical engineering.

[3]  J. Decety,et al.  Effect of brain and spinal cord injuries on motor imagery , 2005, European Archives of Psychiatry and Clinical Neuroscience.

[4]  Electroencephalography artifacts in workplace alertness monitoring. , 2007, Scandinavian journal of work, environment & health.

[5]  Vince Ciotti 20 Years of HCI. , 2010, Healthcare informatics : the business magazine for information and communication systems.

[6]  W Heide,et al.  Electrooculography: technical standards and applications. The International Federation of Clinical Neurophysiology. , 1999, Electroencephalography and clinical neurophysiology. Supplement.

[7]  Rajesh Singla,et al.  EOG and EMG based virtual keyboard: A brain-computer interface , 2009, 2009 2nd IEEE International Conference on Computer Science and Information Technology.

[8]  R L Schoenfeld Common-mode rejection ratio--two definitions. , 1970, IEEE transactions on bio-medical engineering.

[9]  Chun-Liang Hsu,et al.  EOG-based Human-Computer Interface system development , 2010, Expert Syst. Appl..

[10]  A. Cichocki,et al.  The Changing Face of P300 BCIs: A Comparison of Stimulus Changes in a P300 BCI Involving Faces, Emotion, and Movement , 2012, PloS one.

[11]  Andreas Daffertshofer,et al.  Removing ECG contamination from EMG recordings: a comparison of ICA-based and other filtering procedures. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  Richard Brunner,et al.  Registrierung und Analyse des Elektrookulogramms mit einem Personalcomputer. Erste Erfahrungen bei Normalpersonen und Patienten mit Erkrankungen des hinteren Augenabschnitts und intraokulären Fremdkörpern , 1989 .

[13]  Markus H. Muser,et al.  Comparing eye movements recorded by search coil and infrared eye tracking , 2007, Journal of Clinical Monitoring and Computing.

[14]  S. Gais,et al.  Long-term eye movement recordings with a scleral search coil-eyelid protection device allows new applications , 2008, Journal of Neuroscience Methods.

[15]  Jaime Gómez Gil,et al.  Steering a Tractor by Means of an EMG-Based Human-Machine Interface , 2011, Sensors.

[16]  C. Strauss,et al.  How Many Electromyography Channels Do We Need for Facial Nerve Monitoring? , 2012, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  H D Crane,et al.  Generation-V dual-Purkinje-image eyetracker. , 1985, Applied optics.

[18]  HosseinifardBehshad,et al.  Classifying depression patients and normal subjects using machine learning techniques and nonlinear features from EEG signal , 2013 .

[19]  Chun-Liang Hsu,et al.  EOG-based signal detection and verification for HCI , 2009, 2009 International Conference on Machine Learning and Cybernetics.

[20]  Andreas Sprenger,et al.  Overestimation of saccadic peak velocity recorded by electro-oculography compared to video-oculography and scleral search coil , 2010, Clinical Neurophysiology.

[21]  Huosheng Hu,et al.  A novel human–machine interface based on recognition of multi-channel facial bioelectric signals , 2011, Australasian Physical & Engineering Sciences in Medicine.

[22]  T. Jung,et al.  Using novel MEMS EEG sensors in detecting drowsiness application , 2006, 2006 IEEE Biomedical Circuits and Systems Conference.

[23]  Shuyan Hu,et al.  Driver drowsiness detection with eyelid related parameters by Support Vector Machine , 2009, Expert Syst. Appl..

[24]  Yodchanan Wongsawat,et al.  Hybrid EEG-EOG brain-computer interface system for practical machine control , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[25]  V. Pungpapong,et al.  Case-control genome-wide association study of rheumatoid arthritis from Genetic Analysis Workshop 16 using penalized orthogonal-components regression-linear discriminant analysis , 2009, BMC proceedings.

[26]  Abbas Erfanian,et al.  An online EEG-based brain-computer interface for controlling hand grasp using an adaptive probabilistic neural network. , 2010, Medical engineering & physics.

[27]  Pornchai Phukpattaranont,et al.  Development of robust electrooculography (EOG)- based human-computer interface controlled by eight- directional eye movements , 2012 .

[28]  Donghoh Kim,et al.  Comparing patterns of component loadings: Principal Component Analysis (PCA) versus Independent Component Analysis (ICA) in analyzing multivariate non-normal data , 2012, Behavior Research Methods.

[29]  F. Pagnini Psychological wellbeing and quality of life in amyotrophic lateral sclerosis: a review. , 2013, International journal of psychology : Journal international de psychologie.

[30]  Ko Keun Kim,et al.  Common Mode Noise Cancellation for Electrically Non-Contact ECG Measurement System on a Chair , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[31]  Luciano Boquete,et al.  Sensory System for Implementing a Human—Computer Interface Based on Electrooculography , 2010, Sensors.

[32]  Andrew Tucker,et al.  Monitoring eye and eyelid movements by infrared reflectance oculography to measure drowsiness in drivers , 2007 .

[33]  J.R. LaCourse,et al.  An eye movement communication-control system for the disabled , 1990, IEEE Transactions on Biomedical Engineering.

[34]  R. Fazel-Rezai,et al.  A Low Cost Human Computer Interface based on Eye Tracking , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[35]  A. Ludolph,et al.  Amyotrophic lateral sclerosis. , 2012, Current opinion in neurology.

[36]  Danielle Kruger Quick Recertification Series , 2012 .

[37]  E. Marg,et al.  Artifacts and normal variations in human ocular electromyography. , 1959, A.M.A. archives of ophthalmology.

[38]  Mahdi Alshamasin,et al.  Automated Detection of Artifacts in Electroencephalography Signals Using a Linear Prediction Model , 2009, Meditsinskaia tekhnika.

[39]  P Tigges,et al.  Identification of input variables for feature based artificial neural networks-saccade detection in EOG recordings. , 1997, International journal of medical informatics.

[40]  Manuel Mazo,et al.  Wheelchair Guidance Strategies Using EOG , 2002, J. Intell. Robotic Syst..