Hemodynamic patterns of blunt and penetrating injuries.

BACKGROUND The aims of this prospective observational study were to describe early hemodynamic patterns of blunt and penetrating truncal injury and to evaluate outcomes prediction using noninvasive hemodynamic monitoring with a mathematical model tested against actual in-hospital outcomes. The hypothesis was that traumatic shock is a circulatory disorder that can be monitored by noninvasive hemodynamic parameters that reflect cardiac, pulmonary, and tissue perfusion functions. STUDY DESIGN The cardiac index (CI), heart rate (HR), mean arterial pressure (MAP), pulse oximetry (SapO(2)), transcutaneous oxygen tension indexed to FiO(2) (PtcO(2)/FiO(2)), and carbon dioxide (PtcCO(2)) tensions were monitored beginning shortly after emergency department admission in 657 emergency patients with severe blunt and penetrating chest, abdominal, and extremity trauma. Of these, 113 patients had associated head injury, and these patients also were analyzed separately. A search and display mathematical model, with a decision support program, was based on continuous online, real-time, noninvasive hemodynamic monitoring. RESULTS There were similar patterns in the blunt and penetrating injuries; the cardiac index, mean arterial pressure, pulse oximetry, transcutaneous oxygen tension indexed to FiO(2), and survival probability values of the survivors were significantly higher (p < 0.01) than the corresponding values of those who died, although heart rate and carbon dioxide tension were higher in the nonsurvivors during the first 24 hours after their emergency department admission. These patterns occurred more rapidly in patients with penetrating injuries. After initial resuscitation in the emergency department, results were correlated with actual outcomes at hospital discharge and found to be 88% correct. CONCLUSIONS Early noninvasive hemodynamic monitoring with a computerized information system provided a feasible pattern recognition program for outcomes prediction and therapeutic decision support.

[1]  J. Calvin,et al.  Pulmonary Artery Catheter Consensus Conference: the first step. , 1997, Critical care medicine.

[2]  G. Guyatt A Randomized Control Trial of Right-Heart Catheterization in Critically Ill Patients , 1991 .

[3]  Hun H. Sun,et al.  Hemodynamic monitoring by impedance cardiography with an improved signal processing technique , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[4]  Robert W. Taylor,et al.  Pulmonary Artery Catheter Consensus Conference , 1998 .

[5]  L. Goldman,et al.  The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. , 1996, JAMA.

[6]  W. Shoemaker,et al.  Noninvasive hemodynamic monitoring for early warning of adult respiratory distress syndrome in trauma patients. , 2000, Journal of critical care.

[7]  C. Sprung,et al.  Pulmonary Artery Catheter Consensus conference: consensus statement. , 1997, Critical care medicine.

[8]  W. Shoemaker,et al.  Mathematical program for outcome prediction and therapeutic support for trauma beginning within 1 hr of admission: A preliminary report* , 2005, Critical Care Medicine.

[9]  W. Shoemaker,et al.  Prospective, randomized trial of survivor values of cardiac index, oxygen delivery, and oxygen consumption as resuscitation endpoints in severe trauma. , 1995, The Journal of trauma.

[10]  M. Lamy,et al.  The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. , 1994, American journal of respiratory and critical care medicine.

[11]  K. Tremper,et al.  Effects of hypoxia and shock on transcutaneous Po2 values in dogs , 1979, Critical care medicine.

[12]  E. Bennett,et al.  Enhancement of perioperative tissue perfusion as a therapeutic strategy for major surgery. , 1996, New horizons.

[13]  P. Pelosi,et al.  A Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients , 1995 .

[14]  Elevation of systemic oxygen delivery in the treatment of critically ill patients , 1995 .

[15]  H Belzberg,et al.  Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. , 1998, Chest.

[16]  O. Boyd,et al.  The oxygen trail: the goal. , 1999, British medical bulletin.

[17]  W. Shoemaker,et al.  Hemodynamic and oxygen transport patterns after head trauma and brain death: implications for management of the organ donor. , 2007, The Journal of trauma.

[18]  W. Shoemaker,et al.  Survival, hemodynamics, and tissue oxygenation after head trauma. , 2006, Journal of the American College of Surgeons.

[19]  U. Goldbourt,et al.  Use of pulmonary artery catheters in patients with acute myocardial infarction. Analysis of experience in 5,841 patients in the SPRINT Registry. SPRINT Study Group. , 1990, Chest.

[20]  K. Tremper,et al.  Dermal Heat Transport Analysis for Transcutaneous O2 Measurement , 1978, Acta anaesthesiologica Scandinavica. Supplementum.

[21]  Hun H. Sun,et al.  An impedance cardiography system: A new design , 2006, Annals of Biomedical Engineering.

[22]  K. Tremper,et al.  Continuous transcutaneous oxygen monitoring during respiratory failure, cardiac decompensation, cardiac arrest, and CPR: Transcutaneous oxygen monitoring during arrest and CPR , 1980, Critical care medicine.

[23]  Roger W. Jelliffe,et al.  Development of a hemodynamic database in severe trauma patients to define optimal goals and predict outcome , 2001, Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001.

[24]  E. Bennett,et al.  A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. , 1993, JAMA.

[25]  William C. Shoemaker,et al.  Meta-analysis of hemodynamic optimization in high-risk patients* , 2002, Critical care medicine.

[26]  David S. Bayard,et al.  Reduced complexity dynamic programming based on policy iteration , 1992 .

[27]  Roger W. Jelliffe,et al.  Stochastic analysis of therapeutic modalities using a database of patient responses , 2001, Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001.

[28]  L. Goldman,et al.  The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. , 1996, JAMA.

[29]  W. Shoemaker,et al.  Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. , 1988, Chest.

[30]  W. Shoemaker,et al.  Outcome prediction by a mathematical model based on noninvasive hemodynamic monitoring. , 2006, The Journal of trauma.

[31]  W. Shoemaker,et al.  Relationship between supranormal circulatory values, time delays, and outcome in severely traumatized patients , 1993, Critical care medicine.

[32]  H Belzberg,et al.  Outcome prediction of emergency patients by noninvasive hemodynamic monitoring. , 2001, Chest.

[33]  Jean Lonsdorfer,et al.  A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method , 2000, European Journal of Applied Physiology.

[34]  Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery , 1999 .

[35]  I. Woods,et al.  Reducing the risk of major elective surgery: randomised controlled trial of preoperative optimisation of oxygen delivery , 1999, BMJ.

[36]  K. Tremper,et al.  Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock , 1981, Critical care medicine.