An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to compute x-ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP is not semi-empirical and uses no physical assumptions regarding x-ray production, but rather interpolates measured constant potential x-ray spectra published by Fewell et al. [Handbook of Computed Tomography X-ray Spectra (U.S. Government Printing Office, Washington, D.C., 1981)]. X-ray output measurements (mR/mAs measured at 1 m) were made on a calibrated constant potential generator in our laboratory from 50 kV to 124 kV, and with 0-5 mm added aluminum filtration. The Fewell spectra were slightly modified (numerically hardened) and normalized based on the attenuation and output characteristics of a constant potential generator and metal-insert x-ray tube in our laboratory. Then, using the modified Fewell spectra of different kVs, the photon fluence phi at each 1 keV energy bin (E) over energies from 10 keV to 140 keV was characterized using polynomial functions of the form phi (E) = a0[E] + a1[E] kV + a2[E] kV2 + ... + a(n)[E] kVn. A total of 131 polynomial functions were used to calculate accurate x-ray spectra, each function requiring between two and four terms. The resulting TASMIP algorithm produced x-ray spectra that match both the quality and quantity characteristics of the x-ray system in our laboratory. For photon fluences above 10% of the peak fluence in the spectrum, the average percent difference (and standard deviation) between the modified Fewell spectra and the TASMIP photon fluence was -1.43% (3.8%) for the 50 kV spectrum, -0.89% (1.37%) for the 70 kV spectrum, and for the 80, 90, 100, 110, 120, 130 and 140 kV spectra, the mean differences between spectra were all less than 0.20% and the standard deviations were less than approximately 1.1%. The model was also extended to include the effects of generator-induced kV ripple. Finally, the x-ray photon fluence in the units of photons/mm2 per mR was calculated as a function of HVL, kV, and ripple factor, for various (water-equivalent) patient thicknesses (0, 10, 20, and 30 cm). These values may be useful for computing the detective quantum efficiency, DQE(f), of x-ray detector systems. The TASMIP algorithm and ancillary data are made available on line at http:/(/)www.aip.org/epaps/epaps.html.

[1]  H. Kramers,et al.  XCIII. On the theory of X-ray absorption and of the continuous X-ray spectrum , 1923 .

[2]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[3]  T R Fewell,et al.  Photon energy distribution of some typical diagnostic x-ray beams. , 1977, Medical physics.

[4]  R Birch,et al.  Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. , 1979, Physics in medicine and biology.

[5]  Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra. , 1980, Medical physics.

[6]  J M Boone Equivalent spectra as a measure of beam quality. , 1986, Medical physics.

[7]  T. Fewell,et al.  Laplace reconstruction of experimental diagnostic x-ray spectra. , 1988, Medical physics.

[8]  B. Archer,et al.  Determination of diagnostic x-ray spectra with characteristic radiation using attenuation analysis. , 1988, Medical physics.

[9]  J M Boone,et al.  The three parameter equivalent spectra as an index of beam quality. , 1988, Medical physics.

[10]  M J Yaffe,et al.  Effect of finite phosphor thickness on detective quantum efficiency. , 1989, Medical physics.

[11]  M J Yaffe,et al.  Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens. , 1990, Medical physics.

[12]  G. Barnes,et al.  Semiempirical model for generating tungsten target x-ray spectra. , 1991, Medical physics.

[13]  G T Barnes,et al.  Molybdenum target x-ray spectra: a semiempirical model. , 1991, Medical physics.

[14]  L J Schreiner,et al.  A comparison of semiempirical models for generating tungsten target x-ray spectra. , 1992, Medical physics.

[15]  A Fenster,et al.  Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents. , 1993, Medical physics.

[16]  A Fenster,et al.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems. , 1994, Medical physics.

[17]  R Fahrig,et al.  A model for optimization of spectral shape in digital mammography. , 1994, Medical physics.

[18]  R Fahrig,et al.  Optimization of spectral shape in digital mammography: dependence on anode material, breast thickness, and lesion type. , 1994, Medical physics.

[19]  M J Yaffe,et al.  Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors. , 1994, Medical physics.

[20]  J M Boone,et al.  Comparison of x-ray cross sections for diagnostic and therapeutic medical physics. , 1996, Medical physics.

[21]  Measurement of quantum noise in fluoroscopic systems for portal imaging. , 1996, Medical physics.